1
DESCRIPTION
The dual output DGP12 Series provides symmetrical +/– outputs
from 5 volts to 15 volts in packages that provide power densities
up to 7 watts per cubic inch (0.43 watts per cm
3
). Designed to
operate on ultra-wide input voltages from 3.5 to 16 volts, and
with remote ON/OFF capability, the DGP12 supplies power from
battery or system sources . The fully isolated, shielded case allows
precise operation in sensitive environments.
DGP12 SERIES
DUAL OUTPUT
FEATURES
• Remote ON/OFF and TRIM
• Five-Side Shielded Copper Case
• Typical Efficiency up to 78%
• Fully Isolated and Filtered
• 700V Isolation
• Ultra Wide Range Input (4:1)
1
BOTTOM VIEW SIDE VIEW
0.000
0.000
0.25
0.000
2.02
(51.31)
(6.35)
0.040 (1.02) DIA
7 PLACES
0.45
2.02
(11.43)
(51.31)
2
3
7
6
5
4
1.800
0.11
1.100
0.700
0.300
0.100
0.600
0.400
0.51
(7.62)
(2.54)
(13.0)
(17.78)
(15.24)
(10.16)
(27.94)
(45.72)
(2.8)
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
X.XXX dimensions: ±0.005 inches
NOTES
(1) All parameters measured at Tc = 25°C, nominal input voltage and full rated load unless otherwise noted.
Refer to the Technical Reference Section for the definition of terms, measurement circuits and other
information.
(2) See the DGP12 Series Application Notes for more information on applying the ON/OFF pin.
(3) The Case is tied to the -Input pin.
(4) The functional temperature range is intended to give an additional data point for use in evaluating this
power supply. At the low functional temperature the power supply will function with no side effects,
however, sustained operation at the high functional temperature will reduce expected operational life.
The data sheet specifications are not guaranteed beyond the case operating range.
(5) The case thermal impedance is specified as the case temperature rise over ambient per package watt
dissipated.
(6) Output power is reduced at 3.5V input. See DGP12 Series Application Notes for specific
Derating guidelines
Rev. 04/2000
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
2
NOTES
(1) All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise
noted. Refer to the Technical Reference Section for the definition of terms, measurement circuits and
other information.
(2) Reduced output power available below 9 volts input. See DGP12 Series Applications Notes for more
information.
(3) No minimum load required for operation.
(4) Load regulation is defined for loading/unloading both outputs simultaneously. Load range is 25 to
100%.
(5) Cross regulation is defined for loading/unloading one output while the other output is kept at full load.
Load range is 25 to 100%.
(6) Short term stability is specified after a 30 minute warmup at full load, constant line and recording
the drift over a 24 hour period.
(7) Noise is measured per Technical Reference Section. Measurement bandwidth is 0-20 MHz for peak-
peak measurements, 10 kHz to 1 MHz for RMS measurements. Output noise is measured with a
1µF/35V Tantalum capacitor located 1" away from the converter to simulate PCB standard
decoupling.
DGP12 SERIES APPLICATION NOTES:
External Capacitance Requirements
No external capacitance is required for operation of the DGP12
Series. To meet the reflected ripple requirements of the converter,
an input impedance of less than 0.05 Ohms from DC to 100KHz
is required. If a capacitive input source is farther than 1” from the
converter, an additional capacitor may be required at the input
pins for proper operation. External output capacitance is not
required for operation, however it is recommended that 1
F to
10F of tantalum and 0.001 to 0.1F ceramic capacitance be
selected for reduced system noise. Additional output capacitance
may be added for increased filtering, but should not exceed 400F.
Output Power
The available output power of the DGP12 Series is reduced when
operating below 9 volts. See Input Voltage Derating curve. Below
4.6 volts the output power is derated to 50% at 3.5 volts.
(continued next page)