General
Switching Frequency 200 kHz Isolation
Input - Output 500 VDC Input - Case 500 VDC Output - Case 500 VDC
Isolation Resistance - Input to Output 109 Ohms Isolation Capacitance - Input to Output 80 pF No Load Input Power 0.70 W Case Temperature
Standard Operating Range -25 to +85°C
Storage Range -40 to +125°C Humidity Max., Non-Condensing 95% Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz Safety UL, cUL, TUV Weight (approx.) 0.6 oz
1
1
Continuous short circuit protection is provided. Long-term continuous operation in this mode is not recommended. Converter will auto-restart once fault has been removed.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory for specific model information.
Setpoint Accuracy ±5% Line Regulation V
in
Min. - VinMax., I
out
Rated ±1.5% V
out
Load Regulation I
out
Min. - I
out
Max., VinNom. ±2.5% V
out
Minimum Output Current 10% I
out
Rated
Dynamic Regulation, Loadstep 25% I
out
Pk Deviation 1% V
out
Settling Time 500 ms Temperature Coefficient 0.02%/°C Ripple And Noise, 20 MHz BW 150 mV
Short Circuit Protection
1
Continuous
Current Limit 180%
Output
Voltage Range
5 VDC Nominal 4.5 - 9 VDC 12 VDC Nominal 9 - 18 VDC
Reflected Ripple 20% I
in
Max.
Reverse Input Current 100% IinMax.
TECHNICAL SPECIFICATIONS
BWS DC/DC converters offer excellent regulation and isolation in an industry-standard DIP package. The BWS is ideal for industrial, telecom, and networking applications, and features short circuit protection, low profile, and 500 VDC isolation. Please see the BWD series for dual output applications.
• Industry Standard DIP Package
• Industry Standard Pinout
• 85°C Case Operation
• Short Circuit Protection
• Wide Range Inputs
• Input Pi Filter
• Regulated Outputs
• 500V Isolation
Input
DESCRIPTION
FEATURES
BWS SERIES - 2.5 WATT
Notes
REV. 10/01
2
MODEL
INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
BWS0505 5 4.5 - 9 0.85 5 0.5 150 71% BWS0512 5 4.5 - 9 0.95 12 0.25 150 79%
BWS1205 12 9 - 18 0.45 5 0.5 150 70%
BWS1212 12 9 - 18 0.5 12 0.25 150 79% BWS1215 12 9 - 18 0.5 12 0.2 150 79% BWS4805 48 36 - 72 0.10 5 0.5 150 74%
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
BWS SERIES - 2.5 WATT
Thermal Impedance
Natural Convection 23.6 °C/W 100 LFM 16.7 °C/W 200 LFM 13.1 °C/W 300 LFM 9.4 °C/W 400 LFM 8.5 °C/W
Tolerances
Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application.
Pin Function
1 & 24 No Pin 2 & 23 -V
in
/ +V
in
3 & 22 -V
in
/ +V
in 4 & 21 No Pin 5 & 20 No Pin 6 & 19 No Pin 7 & 18 No Pin 8 & 17 No Pin 9 & 16 NC / -V
out 10 & 15 NC / NC 11 & 14 NC / +V
out
12 & 13 No Pin
Inches: .XX ± 0.040 .XXX ± 0.010
Pin: ± 0.002 ± 0.05
(Dimensions as listed unless otherwise
specified.)
(Millimeters) .X ± 1.0 .XX ± 0.25
MECHANICAL DRAWING
MODELS - (See the last page of section for options.)
BOTTOM VIEW
3
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y Encapsulated EWS, IWS, OWS
Pin Length and Heatsink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Units (Except SMS)
0.150" (3.8mm) Pin Length 9 All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink 1H All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad SIP, SM, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink 1V All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad SIP, SM, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink 2H All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad SIP, SM, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink 2V All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad SIP, SM, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink 3H All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad SIP, SM, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink 3V All Units (All Units Except DIP, HLS, HLD, QLS, Includes Thermal Pad SIP, SM, TLD, and TKD Packages)
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
OPTIONS
Loading...