Powernail 2000TN Operation And Maintenance Manual

POWERNAIL® CO.
Model 2000TN Pneumatic Top Nailer™
OPERATION AND MAINTENANCE MANUAL
MANUAL DE OPERACION Y DE MANTENIMIENTO
WARNING
Read this manual before you use this Powernailer®. Follow all safety warnings and instructions. If you are uncertain about the operation of the nailer, call us directly at 1-800-323-1653 for assistance or contact the closest Powernail Dealer for help. Please retain this information for future reference.
REV 14.06.24
INTRODUCTION
The Model 2000TN trigger-pull top nailer is designed to bring Powernail quality and fl ooring expertise to a pneumatic nailer. The Model 2000TN is designed for use with 1” and 1-1/4”, 20 gauge L-Cleat Powernails®.
INDEX
Index..................................... 2
Warranty............................... 2
Safety Instructions................ 3
Operating the tool................. 4
Air Supply............................. 7
Safety Labels........................ 7
Maintenance......................... 7
Troubleshooting Chart.......... 5
Parts List......................... 8
Schematic........................ 9
Phone Support..................... 12
Web Site.............................. 12
Powernail Company Info..... 12
LIMITED WARRANTY
POWERNAIL® Company, Inc. warrants to its customer, and to the fi rst end-use
purchaser of POWERNAIL Model 2000TN POWERNAILER purchased from an
authorized POWERNAIL distributor, that each serialized manufactured Model 2000TN
POWERNAILER by POWERNAIL®, for a period of 12 months from the date of purchase;
shall be free of defects in materials and workmanship and will meet POWERNAIL’S
specifi cations in eff ect at the time of product shipment. POWERNAIL will repair or
replace, at its option, any Model 2000TN POWERNAILER that does not conform to
this warranty. Claims must be made no later than fi fteen (15) days after the end of the
warranty period. POWERNAIL will perform all repair or replacements itself or through its
authorized contractors. POWERNAIL is not responsible for shipping, labor or other direct
or indirect costs. Damage caused by abuse, misuse, unusual or excessive wear is excluded.
Repair or modifi cation of the Products by unauthorized parties will void this warranty.
The customer is responsible for returning Products to POWERNAIL for verifi cation of
nonconformance. Warranties for Products not manufactured by POWERNAIL are limited
to warranties provided to POWERNAIL by the manufacturer of such product that are
assignable to customer.
THESE WARRANTIES AND REMEDIES ARE EXCLUSIVE OF ALL OTHERS,
EXPRESS OR IMPLIED. THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR PURPOSE ARE EXPRESSLY EXCLUDED. IN NO EVENT SHALL
POWERNAIL’S LIABILITY FOR A WARRANTY CLAIM EXCEED THE PRICE PAID
TO POWERNAIL FOR THE NONCONFORMING PRODUCT, REGARDLESS OF THE
FORM OR BASIS OF THE CLAIM OR CAUSE OF ACTION.
2
SAFETY INSTRUCTIONS
When operating this Nailer, the operator and others in the work area should ALWAYS wear approved SAFETY GLASSES, with front and side eye protection. Eye protection will help guard against fl ying nails and debris, which could cause severe eye injury.
EAR PROTECTION should be used to prevent hearing damage when there are high noise levels in the work area. ALWAYS use ear plugs with a noise reduction rated at 29 db or higher at a construction site.
Nailer noise ratings are at LPA-1sd=90.6,
LWA-1sd=99.3 and LPA-1s,1m=86.3. Nailer vibration rating: m/s2=3.05.
Always DISCONNECT THE AIR SUPPLY before making any adjustments, repairing, clearing jams or when the Nailer is not in use. Do not use on scaff olding or ladders and disconnect nailer from air supply when transporting between installation areas.
Never attach the female end of a quick disconnect to the Nailer. This will trap air inside the Nailer and permit it to be discharged. Only the unrestricted male connection should be attached to the Nailer.
Nailer requires an air source that can continuously deliver 70 to 110 psi at 3-1/2 cubic feet of air per minute for operation. Normal air pressure should not exceed 110 psi or damage to the Nailer and seals may occur. Excess air pressure can cause the Nailer to explode.
To prevent fi re or explosion, use only regulated compressed air—do not use bottled gases of any kind (no oxygen or combustible gasses) to power this Nailer.
Nailer is intended for use installing wood fl ooring and is not to be used for purposes not specifi ed in the operations manual.
Do not use any nails other than Powernail® Powercleats which are 20 gage L-cleat nails specifi cally designed for use in any 20 gage Powernailer. Powercleat nails are available in lengths of 1” and 1-1/4”. Contact your Powernail Dealer for the correct Powercleats for the Model 2000TN.
Use only Powernail replacement parts in the repair or maintenance of this nailer. Parts or repair services are available from the manufacturer or from agents authorized by the manufacturer. Repairs should be carried out only by trained service personel in the fi eld of fastener driving tools who will observe proper safety controls while performing maintenance. Service personel should be qualifi ed to assess the safe working condition of fastener driving tools.
Always make sure Nailer is empty of nails before connecting air hose, so as to prevent any accidental discharge from occurring. ONLY CONNECT AIR TO AN UNLOADED NAILER.
Do not depress the trigger when loading. If the fasteners are jammed, disconnect the tool from the air supply before you remove the jammed nails.
Never place any part of the body in the discharge path of the Nailer when air is connected to the Nailer. Never point the tool at yourself or others, even if the tool is not loaded. For safety, keep out of reach of children. Never leave the Nailer unattended while it is connected to an air supply.
Do not fi re into hard materials or attempt to use on hard or brittle material such as concrete, steel
or tile. Before using this tool, carefully check that all parts are working correctly. Do not use the tool if it is not operating correctly, check for causes and adjust as necessary for proper operation. When not in use, the tool should be cleaned, fully assembled and then stored in a dry location. This will extend the life of the tool and reduce any oxidation.
3
OPERATION
To use the Model 2000TN, simply place the silver foot of the nailer against the fl ooring you wish to nail so that the safety mechanism is engaged. Gently squeeze the trigger and the nailer will drive and countersink the nail.
Trigger-pull Operation!
Adjustable Exhaust Port
Silver Nailer Foot
Floor activated safety mechanism
prevents accidental tool activation.