Premium Plus – ELECTRIC GENERATOR
Premium Plus – GÈNÈRATRICE ÉLECTRIQUE
Premium Plus – GENERADOR ELECTRICO
IMPORTANT – Please make certain that persons who are to use this equipment thoroughly read and
understand these instructions and any additional instructions provided prior to operation.
IMPORTANT - Prière de vous assurer que les personnes destinées à utiliser cet appareil ont pris soin d'en lire
et d'en comprendre le mode d'emploi ou les directives avant de le mettre en marche.
IMPORTANTE. Asegúrese que las personas que utilizarán este equipo lean y entiendan completamente estas
instrucciones y cualquier instrucción adicional proporcionada antes del funcionamiento.
www.colemanpowermate.com LFL 05/02 0061573
MAJOR GENERATOR FEATURES
ELECTRIC START MODELS
*10 HP Briggs & Stratton OHV engine
*Low oil sensor
*Receptacles on control panel
*Electric Start
*Automatic voltage regulator (AVR)
*5 gallon plastic fuel tank
*Portability Kit
CONTROL PANEL
A. 120 V, 20 Ampere Duplex Receptacle
This duplex is split so that 20 amps of current may be
drawn from each half of the receptacle. However, total power
drawn must be kept within nameplate ratings. These
receptacles may be used along with the twistlock receptacle
provided the generator is not overloaded.
B. 120/240 V, 20 Ampere Twistlock Receptacle
A maximum of 20 amps may be drawn from the 120/240
volt receptacle, provided it is the only receptacle used.
However, current must be limited to the nameplate rating. If the
120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.
ELECTRIC START WIRING
This model is equipped with a trickle charge system. The
14 AWG (American Wire Gauge) red wire which comes from
the engine should be connected to the positive battery terminal
(see engine operator manual).
The battery is customer provided. Supplied with your
generator are #8 AWG (American Wire Gauge) copper leads.
Provide a lead from the push button switch to the positive (+)
battery terminal and a lead from the chassis of the generator to
the negative (-) battery terminal.
WARNING: Batteries contain sulfuric
acid (when filled). May contain explosive
gasses. Always abide by safety warnings
provided with the battery.
-Keep sparks, flame and cigarettes away.
-Hydrogen gas is generated during
charging and discharging.
-Always shield eyes, protect skin and
clothing when working near batteries.
BASIC WIRING DIAGRAM
C. Circuit Breakers
The receptacles are protected by an AC circuit breaker. If
the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip. If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. NOTE:
Continuous tripping of the circuit breaker may cause
damage to generator or equipment. The circuit breaker may
be reset by pushing the button of the breaker.
2
English
BATTERY KIT PARTS LIST
Item DescriptionQty.
A.*Bolt, 1/4-20X8”2
B.*Washer 1/42
C.Hold Down bar (PN 0036525.02)1
D.*Nyloc nut, 1/4-202
E.*Spacer (optional)2
*All parts are standard parts at your local hardware store.
LIMITED WARRANTY
(NOT VALID IN MEXICO)
This product is warranted by Coleman Powermate, Inc. to the
original retail consumer against defects in material and
workmanship for a period of two years from the date of retail
purchase and is not transferable. This two year warranty
applies only to products used in consumer applications. If this
generator is used in a commercial application, then the period
of warranty coverage is limited to ninety (90) days from the date
of purchase.
CAUTION: This battery charging system is intended to
recharge weak batteries, not to “boost start” vehicles.
Battery Installation
Coleman Powermate recommends a 12 v battery with at
least 235 cranking amps. Model U1L, Lawn and Garden
Battery. Place the battery in the position provided. Then place
the bolts through the loops on the Hold-Down bracket. Place
the assembly over the battery and place the bolts through the
holes on the battery pan and tighten down the Hold-Down
assembly with the 1/4-20 nuts provided.
Spacers may be added depending on the battery height.
WARNING: Batteries contain sulfuric acid
(when filled). May contain explosive gasses.
Always abide by safety warnings provided
with the battery.
-Keep sparks, flame and cigarettes away.
-Hydrogen gas is generated during charging
and discharging.
-Always shield eyes, protect skin and clothing
when working near batteries.
Connect the Rd 8ga. battery lead to the positive battery
post and the black 8ga. battery to the negative battery post with
the bolts and nuts provided.
Please complete and return the enclosed Customer
Information Card so that we can reach you in the unlikely event
a safety recall is needed. Return of this card is not required to
validate this warranty.
WHAT IS COVERED: Replacement parts and labor.
WHAT IS NOT COVERED: Transportation charges to
Coleman Powermate, Inc. for defective products.
Transportation charges to consumer for repaired products.
Brushes, fuses, rubber feet, and receptacles. Damages
caused by abuse, accident, improper repair, or failure to
perform normal maintenance. Power units or engines which
are covered exclusively by the warranties of their manufacturer.
Sales outside of the United States or Canada. Any other
expense including consequential damages, incidental
damages, or incidental expenses, including damage to
property. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
IMPLIED WARRANTIES: Any implied warranties, including
the Implied Warranties of Merchantability and Fitness For A
Particular Purpose, are limited in duration to two (2) years from
the date of retail purchase. Some states do not allow
limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
English
BATTERY INSTALLATION
HOW TO OBTAIN WARRANTY PERFORMANCE:
Replacement parts and service are available from Coleman
Powermate, Inc. Service Centers. Locate your nearest Service
Center by calling TOLL FREE 1-800-445-1805. In the unlikely
event a Service Center can not be located you may call
Coleman Powermate, Inc. for a return authorization number.
Any unit returned WITHOUT an authorization number will
be refused.
To the extent any provision of this warranty is prohibited by
federal, state, or municipal law, and cannot be preempted, it
shall not be applicable. This warranty gives you specific rights,
and you may also have other rights which vary from state to
state.
3
CARACTÉRISTIQUES PRINCIPALES DE LA
GÉNÉRATRICE
CÂBLAGE DU DÉMARREUR
ÉLECTRIQUE
*10 HP Briggs & Stratton OHV moteur
*Le détecteur d’huile bas niveau
*Prises sur tableau de commande
*Démarreur électrique
*La tension automatique régulatrice
*Réservoir de carburant en plastique d'une
contenance de 18.9 litres (5 gallons)
*Nécessaire de portabilité
TABLEAU DE COMMANDE
A. Prise double de 120 V, 20 A
Cette prise double est câblée pour fournir 20 A. La
charge totale doit cependant rester dans les limites indiquées
sur la plaque signalétique. Ces prises peuvent s’utiliser en
conjonction avec la prise à verrouillage à condition que la
génératrice ne soit pas surchargée.
B. Prise à verrouillage de 120/240 V, 20 A
Cette prise de 120/240 V fournit un maximum de 20 A à
condition que ce soit la seule utilisée. La charge totale doit par
ailleurs rester dans les limites indiquées sur la plaque
signalétique. Si la prise de 120/240 V est utilisée en
conjonction avec les prises de 120 V, la charge totale ne doit
pas dépasser les limites indiquées sur la plaque.
CÂBLAGE ÉLECTRIQUE AU DÉMARRAGE
Votre moteur est équipé d’un système de charge
d’entretien. Le fil rouge #14 AWG (American Wire Gauge)
sortant du moteur doit être branché à la cosse positivede la
batterie (Voir le manuel de l’opérateur du moteur).
Pour certains modèles, la batterie et les fils de la batterie
doivent être fournis par le client. Utilisez des fils de cuivre #8
AWG (American Wire Gauge). Installez un fil de l’interrupteur à
bouton poussoir à la cosse positive (+) de la batterie et un fil du
châssis du générateur à la cosse négative (-) de la batterie.
ATTENTION: Les batteries contiennent de
l’acide sulfurique) lorsqu’elles sont pleines).
Elles peuvent également produire des gaz
explosifs. Toujours observer les mesures de
sécurité recommandées par le fabricant.
–Ne pas fumer à proximité de batteries, les
garder à distance süre de toute source
d’étincelles ou de flamme.
–De l’hydrogène est produit pendant la
décharge et la recharge de la batterie.
–Toujours protéger les yeux, la peau et les
vêtements lorsqu’on travaille à proximité
de batteries.
DIAGRAMME DE CÂBLAGE DE BASE
C. Disjoncteurs
Les prises sont protégées par un disjoncteur alternatif. En
cas de surcharge ou de court-circuit extérieur, le disjoncteur
saute. Si cela se produit, débrancher tout appareil relié à la
génératrice et essayer de déterminer la cause du problème
avant d’essayer de la réutiliser. Si le disjoncteur saute en
raison d’une surcharge, réduire la charge. REMARQUE : La
génératrice ou les appareils branchés dessus peuvent se
trouver abîmés si le disjoncteur saute continuellement.
Appuyer sur le bouton du disjoncteur pour le réenclencher.