Power Inspired VIX3065, VIX3100, VIX3085, VIX3150, VIX3200 User Manual

POWER
Inspired
VIX3000 Series Line Interactive
UPS System
Important Safety Warning (SAVE THESE INSTRUCTIONS)
CAUTION!
acceptable temperature and humidity range.) CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output. CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit. CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS. CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during
UPS installation in order to reduce leakage current below 3.5mA. Attention hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary. CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries. CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery. CAUTION!
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. CAUTION! A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
If your UPS came with a software CD, follow the instructions on the CD, otherwise:
1. Go to the website http://www.power-software-download.com
2. Click ViewPower software icon and then choose your required OS to download the software.
3. Follow the on-screen instructions to install the software.
Software Download & Installation
Power Inspired Ltd. Units 5-7 High Point, Riding Road, Brackley UK.
Tel: 01280 811180
www.powerinspired.com
VIX3000-REV1
Model VIX3065 VIX3085 VIX3100 VIX3150 VIX3200
CAPACITY INPUT
Voltage Voltage Range OUTPUT Voltage Regulation Transfer Time Waveform BATTERY Type & Number Charging Time
PHYSICAL
Dimension (DxWxH mm) Net Weight (kgs)
ENVIRONMENT
Humidity Nosie Level
MANAGEMENT
USB
650VA/360W 850VA/480W 1000VA/600W 1500VA/900W 2000VA/1200W
287 x 100 x 142 350x146x160 397 x 146 x 205
12V/7AHx1 12V/9AHx1 12V/7AHx2 12V/9AHx2 12V/9AHx2
4-6 hours recover to 90% capacity
4.25 4.9 8.0 11.1 11.5
220/230/240 VAC
162-290 VAC
+/-10%
Typical 2-6 ms, 10 ms max.
Simulated Sine Wave
0-90 % RH @ 0-40 C (non-condensing)
Less than 40 dB
Supports Windows® 2000/2003/XP/Vista/2008, Windows®7/8
Linux, Unix and MAC
6
4
5
7
8 3 9
Product Overview
Introduction
Thank you for purchasing a Power Inspired Uninterruptible Power Supply. For further information on this product or for support please visit www.powerinspired.com/vix3000/
Installation & Operation
NOTE: Before installation, please inspect the unit. Be sure that nothing inside
the package is damaged.
Placement & Storage Conditions
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT
operat
check the specs for the limitations.)
6 hours
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results,
suggest to charge the battery at least 6 hours before initial use.
The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the
power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit.
Connect Modem/Phone/Network for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of
the UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
Connect Communication Cable
To allow for unattended UPS shutdown/start-up and status monitoring, connect the
communication cable one end to the USB/RS-232 port and the other to the communication
port of your PC. With the monitoring software installed, you can schedule UPS
shutdown/start-up and monitor UPS status through PC.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch.
Turn off the UPS by pressing the power switch again.
Problem Possible Cause Solutions
AC input is not connected well.
Check if the input power
connected to the mains. AC input is connected to the UPS output.
Plug AC input power cord to AC input
correctly.
Battery backup time is shorter than nominal value.
Batteries are not fully charged.
Charge the batteries at least 6 hours
and then check the capacity again.
If the problem still persists, please
consult your dealer. Batteries defect. Contact your dealer to replace the
batteries.
Warning or fault icon is shown and alarm is continuously sounding.
Fan is locked or not working. Check fans and notify your dealer. The UPS is overload.
reconnecting devices, please verify
the total loads match the UPS
spec. Low battery icon is shown on the LCD screen.
Low battery. Charge the UPS at least 6 hours.
Troubleshooting
LCD blank / No LEDs illuminated when mains is normal
Power switch
LCD panel
Output receptacles AC input Circuit breaker / Fuse
Modem/Phone/Network surge protection
USB com port
1 2
3 4
5
Power switch
UPS status LED
AC mode: green lighting
LED Models
LCD Models
CAUTION: NEVER connect a laser printer or scanner to
the UPS unit. This may cause the damage of the unit.
Fault : Red lighting
1. Input information 6. Battery capacity indicator
2. Output information 7. Overload indicator
3. AC mode indicator 8. Low battery indicator
4. Battery mode indicator 9. Fault indicator
5. Load level indicator
650V/850VA
2
4
5
1
1
2
3
4
5
1
4
2
5
1KVA 1.5KVA/2KVA