THE FLUORACTOR® Y1112L
FLUORESCENT LAMP STARTER SWITCH
PRODUCT INFORMATION
1
MARCH 1998 - REVISED MAY 1998Copyright © 1998, Power Innovations Limited, UK
Fluoractor® is a Registered Trade Mark of Power Innovations Ltd
V
(BR)
1200 to 1500 V
I
H
> 175 mA
I
GT
< 2 mA
description
This product is intended for use as a T8/T12 fluorescent tube starter switch on 200-240 V a.c. supplies with tube sizes up to 5 ft with leading and lagging ballast circuits.
K A G
1 2 3
L PACKAGE
(TOP VIEW)
Pin 2 is in electrical contact with the heat slug.
MDXXAO
absolute maximum ratings at 25°C case temperature (unless otherwise noted)
RATING SYMBOL VALUE UNIT
Crest working off-state voltage (Full wave rectified 50 Hz a.c.) V
DWM
375 V
Peak reverse gate voltage V
RGM
6 V
On-state current — continuous
— repetitive peak — non-repetitive peak
I
T
I
TRM
I
TSM
1.5 2
10
A
Peak gate current I
GRM
0.5 A
Average gate power P
G(av)
0.3 W
Operating case temperature range T
C
-5 to +85 °C
Storage temperature range T
stg
-10 to +110 °C
Lead temperature during soldering 1.6 mm from the case for 10 seconds T
lead
230 °C
electrical characteristics at 25°C case temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
D
Off-state current VD = V
DWM
Tj = 65°C 1 mA
V
T
On-state voltage IT= 2 A 3.1 V
V
(BR)
Clamping voltage I
(BR)
= 5 mA tp< 200 µs, 2% duty cycle 1200 1500 V
I
H
Holding current See application circuit 175 mA
I
GTM
Peak gate trigger current
V
AA
= 10 V RL= 10 2 mA
V
GTM
Peak gate trigger voltage
V
AA
= 10 V RL= 10 3 V
THE FLUORACTOR® Y1112L FLUORESCENT LAMP STARTER SWITCH
2
MARCH 1998 - REVISED MAY 1998
PRODUCT INFORMATION
applications data
The conventional method of starting fluorescent tubes employs the use of an electromechanical canister. This consists of a bimetallic strip which opens as it cools and in conjunction with the ballast inductor, provides the tube striking voltage. However, the random nature of the pulsing results in repeated striking attempts and degradation of both the tube and starter. The tube degradation is illustrated by its progressively blackening ends and ultimately required tube replacement.
The Y1112L, “Fluoractor
®
”, has been specifically introduced for use in electronic starters. This unique device offers the lighting industry an opportunity to develop electronic starters small enough to be retrofit replacements for the established electromechanical canisters. Its double thyristor structure with integrated zener clamp diode and current mirror provides the technology for a starter with enhanced features such as controlled flicker free start up, automatic tube shutdown at end of tube life and reduced degradation of tube ends leading to extended life. The increased functionality, lifetime and reliability of these starters has led in some cases to them being embodied in the ballast itself, a development not feasible with the old electromechanical canisters.
NOTE 1: These rectifiers need to be voltage selected for VR ≥ V
(BR)max
+ 150 V
Figure 1. Two terminal starter circuit
R1
150 k
R6
330 k
R2
68 k
R3
6.8 k
R4
270 k
R5
4.7 k
D7
D6
Y1112L
ΤΗ2
D5
C1
100
µ
F
D1 to 4
(see Note 1)
A
K
G
D8