Power Innovations TISP4290LP Datasheet

SYMMETRICAL TRANSIENT
VOLTAGE SUPPRESSORS
APRIL 1987 - REVISED SEPTEMBER 1997Copyright © 1997, Power Innovations Limited, UK
TELECOMMUNICATION SYSTEM SECONDARY PROTECTION
TISP4290LP
Ion-Implanted Breakdown Region
Precise and Stable Voltage Low Voltage Overshoot under Surge
V
VV
(Z)
DEVICE
‘4290LP 200 290
(BO)
V
Planar Passivated Junctions
Low Off-State Current<10 µA
Rated for International Surge Wave Shapes
I
WAVE SHAPE STANDARD
8/20 µs ANSI C62.41 150
0.2/310 µs RLM 88 38 10/700 µs
VDE 0433
CCITT IX K17
Package Options
PACKAGE PACKING PART # SUFFIX
LP Bulk None
LP with fomed leads Tape and Reel R
TSP
A
50 38
A(T)
NC
B(R)
A(T)
NC
B(R)
device symbol
LP PACKAGE
(TOP VIEW)
NC - No internal connection
LP PACKAGE
WITH FORMED LEADS
(TOP VIEW)
NC - No internal connection
1 2 3
MDTRAB
1 2 3
MD4XAF
UL Recognized, E132482
description
The TISP4290LP is designed specifically for telephone equipment protection against lightning and transients induced by a.c. power lines. These devices consist of a bidirectional suppressor element connecting the A and B terminals. They will suppress inter-wire voltage transients.
Transients are initially clipped by zener action until the voltage rises to the breakover level, which causes the device to crowbar. The high crowbar holding current prevents d.c. latchup as the transient subsides.
These monolithic protection devices are fabricated in ion-implanted planar structures to ensure precise and matched breakover control and are virtually transparent to the system in normal operation.
PRODUCT INFORMATION
Information is current as of publication date. Products conform to specifications in accordance with the terms of Power Innovations standard warranty. Production processing does not necessarily include testing of all parameters.
1
TISP4290LP SYMMETRICAL TRANSIENT VOLTAGE SUPPRESSORS
APRIL 1987 - REVISED SEPTEMBER 1997
absolute maximum ratings at 25°C case temperature (unless otherwise noted))
RATING SYMBOL VALUE UNIT
Non-repetitive peak on-state pulse current(see Notes 1, 2 and 3)
8/20 µs(ANSI C62.41, open-circuit voltage wave shape 1.2/50 µs) 150 5/200 µs(VDE 0433, open-circuit voltage wave shape 2 kV, 10/700 µs) 50
0.2/310 µs(RLM 88, open-circuit voltage wave shape 1.5 kV, 0.5/700 µs) 38
5/310 µs(CCITT IX K17, open-circuit voltage wave shape 1.5 kV, 10/700 µs) 38 Non-repetitive peak on-state current, 50 Hz, 1 s(see Notes 1 and 2) I Initial rate of rise of on-state current,Linear current ramp, Maximum ramp value < 38 A di Junction temperature T Operating free - air temperature range 0 to 70 °C Storage temperature range T Lead temperature 1.5 mm from case for 10 s T
NOTES: 1. Above 70°C, derate linearly to zero at 150°C case temperature
2. This value applies when the initial case temperature is at (or below) 70°C. The surge may be repeated after the device has returned to thermal equilibrium.
3. Most PTT’s quote an unloaded voltage waveform. In operation the TISP essentially shorts the generator output. The resulting loaded current waveform is specified.
.
I
TSP
TSM
/dt 250 A/µs
T
J
stg
lead
2.5 A rms
150 °C
-40 to +150 °C 260 °C
A
electrical characteristics, TJ = 25°C
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Reference zener
V
Z
voltage Temperature coefficient
V
Z
of reference voltage Breakover voltage (see Notes 4 and 5) ± 290 V
V
(BO)
Breakover current (see Note 4) ± 0.15 ± 0.6 A
I
(BO)
Peak on-state voltage IT = ± 5 A (see Notes 4 and 5) ± 2.2 ± 3 V
V
TM
Holding current (see Note 4) ± 150 mA
I
H
Critical rate of rise of
dv/dt
off-state voltage Off-state leakage
I
D
current Off-state capacitance VD = 0 f = 1 kHz 70 150 pF
C
off
= ± 1mA ± 200 V
I
Z
(see Note 6)
= ± 50 V ± 10 µA
V
D
NOTES: 4. These parameters must be measured using pulse techniques, t
5. These parameters are measured with voltage sensing contacts seperate from the current carrying contacts located within 3.2 mm (0.125 inch) from the device body.
6. Linear rate of rise, maximum voltage limited to 80 % V
(minimum).
Z
.
thermal characteristics
PARAMETER MIN TYP MAX UNIT
Junction to free air thermal resistance 156 °C/W
R
θJA
= 100 µs, duty cycle 2%.
w
0.1 %/
± 5 kV/µs
o
C
PRODUCT INFORMATION
2
SYMMETRICAL TRANSIENT
VOLTAGE SUPPRESSORS
APRIL 1987 - REVISED SEPTEMBER 1997
PARAMETER MEASUREMENT INFORMATION
TISP4290LP
Figure 1. VOLTAGE-CURRENT CHARACTERISTICS FOR TERMINALS A AND B