Powerhouse PH2700PRI, PH2100PRI User Manual

PH21/27 POWERHOUSE®
Dual Generator Parallel Kit
Operating Instructions
PLEASE READ THIS MANUAL CAREFULLY
BEFORE USING
TABLE OF CONTENTS
TABLE OF CONTENTS ..................................................................................................................... 2
1. SAFETY INSTRUCTIONS: ......................................................................................................... 2
2. Parallel Operating Features: ....................................................................................................... 2
3 Parallel Operation Procedure: ........................................................................................................ 3
3.1 Parallel Output and Overload Lights ................................................................................................... 4
3.2 Shutting off the generators: ................................................................................................................. 5
3.3 Air Conditioning Operation .................................................................................................................. 5
4 Troubleshooting Parallel Operation ................................................................................................. 6
1. SAFETY INSTRUCTIONS:
Follow all safety and operating instruction for proper use of the
generator.
Never Connect or Disconnect the parallel kit cables from the
generators while running. Doing so will cause perminate damage not covered under warranty.
The load requirement of the electrical appliance cannot exceed the
combined continual output of the paralleled generators.
The special parallel cables for the PH2100PRi and PH2700PRi are
specific to the parallel operation of two POWERHOUSE® generators. DO NOT use them for other brands of generators or other applications.
This kit cannot be used for paralleling three or more generators or
running two different brands of generators.
ONLY the POWERHOUSE® Dual Generator Parallel Kit and cables
may be connected to the parallel signal port. DO NOT CONNECT TO OTHER ELECTRONICS OR USE OTHER CABLES. Permanent damage not covered by the warranty will occur.
2. Parallel Operating Features:
1. Two PH2100PRi or PH2700PRi model generators can run in parallel to increase the total output to a
maximum load of.
4200 W (Continual output, 4000 W) with the PH2100PRi.  5200 W (Continual output, 5000 W) with the PH2700PRi.
2. You can also run a PH2100PRi and a PH2700PRi in parallel. The maximum output will be 4200 W (Continual output, 4000 W).
3 Parallel Operation Procedure:
3-Pin Parallel
Cable ‘A’
3-Pin Parallel
Cable ‘B’
Cover
Parallel Signal Port
3-Pin Parallel Power Socket
Cover
PH2100PRi/PH2700PRi
1. Prepare two POWERHOUSE® generators for operation.
2. Parallel power and signal connections MUST be done with the generator engine NOT running. DO NOT connect or disconnect the parallel power or signal cables while the engine is running. Irreparable inverter damage WILL result and is not covered under warranty.
3. Connect the 15-pin signal cable between the parallel kit and each generators signal ports and secure
with the thumb screws. Do not over tighten.
4. Connect the 3-pin parallel power cable from the parallel kit into each generators parallel power sockets making sure that the cables for generator ‘A’ and generator ‘B’ are not switched.
5. Start both generators and confirm that both green "RUN" lights are illuminated on the generators and on the front panel of the parallel kit.
6. Start both generators. The starting procedure is the same as the normal starting procedure.
7. Securely plug the electrical appliance plug into the appropriate receptacles and switch on the
electrical appliance.
When running the generators in parallel, the economy function will
automatically be turned off and both units will be running at the higher engine speed.
Loading...
+ 4 hidden pages