Power Gems EB180PD User Manual

EB180PD
Electronic Ballast
Operating Guide
Power Gems Ltd
Unit 1, Fairhills Trade Centre,
Fairhills Road, Irlam,
Manchester, M44 6BA
Tel: +44 (0)161 776 7030
Fax: +44 (0)161 776 7039
www.powergems.com
Power Gems Corporation
26320 Diamond Pl., Suite 180
Santa Clarita
California 91350
USA
Tel: +1 818 376 1800
Fax: +1 818 376 1801
Front Panel Controls
Start & Stop Buttons
Mode Select Power Switch
Power In Dimmer / DMX Channel Select
Quick Start
Connect to the supply, plug the luminaire into the output connector, power up using the power switch and press Start. The lamp should strike and will normally take a couple of minutes to warm up. Should there be a problem the ballast will shut down and indicate what is wrong.
Power in
The EB180PD should be connected to an AC supply in the range 100-265V or a DC supply in the range 48-60V DC. If the input voltage dips below the minimum rated value the ballast will switch into an under-voltage mode — the lamp will keep running, but switches to a low power until the voltage is restored. In the case of severe under-voltage the ballast will shut down. Over-voltage on the input should be avoided as this can lead to damage.
The Earth wire (green/yellow) in the mains cable must be connected to the supply safety earth to ensure operator safety.
Output connectors
The connectors may be able to supply a range of different lamp powers depending on the wiring configuration. This is indicated under each output socket. Only one lamp may be connected at any time.
Output Connector
The ballast will automatically detect which socket is in use and apply the appropriate power to the lamp. If an 1800W lamp is detected the mode LED will flash.