Power-Flo Technologies PFUPPP2528251M10 User Manual

OWNER’S MANUAL
Model: PFUPPP2528251M10
1/4 HP • 3450 RPM • 60 Hz
Submersible Utility Pump
Power-Flo Pumps & Systems 877-24PUMPS www.poweropumps.com
ISP No: PFUPPP25 - 8/01/15
PFUPPP2528251M10 Submersible Utility Pumps
Before installation, read the following instructions carefully. Failure to follow instruction and Safety information could cause serious bodily injury, death and/or property damage. Each Power-Flo pump is individually factory tested to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
IMPORTANT - Power-Flo Pumps and
Systems is not responsible for losses, injury or death resulting from failure to observe these safety precautions, misuse, abuse or misapplication of pumps or equipment.
Do not pump ammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not
use in the presence of ammable or explosive vapors. Using this pump with or near ammable liquids can cause an explosion or re, resulting in property damage, serious personal injury, and/or death.
ALWAYS disconnect the power to the pump
before servicing.
Release all pressure and
drain all water from the system before servicing any component.
Do not touch the
motor housing during
operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing.
Do not handle the
pump or pump motor
with wet hands or when standing on a wet or damp surface, or in water before disconnect the power.
Secure the discharge
line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage.
Extension cords may
not deliver sucient
voltage to the pump motor. Extension cords present a life
threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted.
Wear safety goggles at
all times when
working with pumps.
This unit is designed
only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualied electrician.
Protect the electrical
cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.
Failure to comply with
the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
Ensure that the
electrical circuit to the pump is protected by a 10 Amp fuse or circuit breaker.
Do not lift the pump by the power cord.
Know the pump and its applications,
limitations, and potential hazards.
IMPORTANT ! - Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum eciency. It will also help prevent the pump from clogging resulting in premature failure.
IMPORTANT ! - Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting.
Follow all local
electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Administration (OSHA) guidelines must be followed.
The motor of this pump
has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in.
Ensure the electrical power source is
adequate for the requirements of the pump.
Before using the pump,
check the hose for holes or excess wear, which could cause leaks, and ensure the hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly, and also check that all hose connections are tight to minimize leaks.
IMPORTANT ! - This pump is made of high­strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail.
® Power-Flo is a registered trademark of Power-Flo Technologies Inc. Alteration Rights Reserved. 3/15, 8/15
Power-Flo Pumps & Systems • 877-24PUMPS • www.poweropumps.com
2
PFUPPP2528251M10 Submersible Utility Pumps
Specications
Features:
Portable submersible utility pump for water removal or emptying shallow ooded areas.
DISCHARGE: 1” NPTM, Vertical, with 3/4” Garden Hose Adapter
LIQUID TEMPERATURE: 32°-77°F
MOTOR HOUSING: Corrosion-resistant, reinforced Thermoplastic
with T-Handle for easy portability.
IMPELLER: Corrosion-resistant, reinforced Thermoplastic
SUCTION PLATE: Corrosion-resistant, reinforced Thermoplastic,
Bottom suction design lters debris and removes water down to 1/8”
SHAFT: Stainless Steel
HARDWARE: Stainless steel
GASKET: Rubber
SEAL: Single mechanical, rubber and stainless steel
UPPER BEARING: Single row, ball, oil lubricated
LOWER BEARING: Single row, ball, oil lubricated
POWER CORD: SJTW, 18AWG/3C Cord, with plug. 10 ft long
MOTOR: Energy ecient Permanent Split Capacitor (PSC), Oil
Filled, Class B insulation, Continuous duty (water depth must be at least 6” to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments 10 AMPS.
WARRANTY: 3 year
Submersible Utility Pump
1” NPT Discharge,
1/8” Spherical Solids
Manual Operation
MODEL HP Hz Volts/Ph RPM
AMPS
PFUPPP2528251M10 1/4 60 115/1 3450 2.3 10 ft 4.8 lbs
HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft 20 Ft 25 Ft
FLOW Gallon/Minute 25 23 20 16 13 8
FLOW Gallon/Hour 1500 1370 1190 960 780 500
PF
Power-Flo U = Utility
EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30” Shut O Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10’ Cord
TYPE
U, SP, SW
SP = Sump Pump SW = Sewage Pump
Motor Housing
P, C
P = Plastic C = Cast Iron
Impeller Type
P, C
P = Plastic C = Cast Iron
Suction Plate Type
P, C
P = Plastic C = Cast Iron
25, 33, 50, 75, 1
25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP
Power-Flo Pumps & Systems • 877-24PUMPS • www.poweropumps.com
FL
Motor HP
1 = 1 HP
Cord
Length
Max
Lift
Pressure
28 Ft 12.4 psi
30 50
Shut O
Head (ft)
Wt.
Max
Max Flow
(Gal)
Voltage
1 or 2
1 = 115 V 2 = 230V
Float Switch Type
M, F, T
M = Manual F = Fixed Vertical T = Tethered
Cord Length
10, 15
10 Ft 25 Ft
3
Loading...
+ 5 hidden pages