Power-flo PFSE1524, PFSE1594, PFSE1544, PFSE2024, PFSE2094 Installation, Service & Parts Manual

...
Page 1
INSTALLATION, SERVICE & PARTS MANUAL
Series: PFSE1524, PFSE1594 PFSE1544, PFSE2024, PFSE2094, PFSE2044 PFSE3024, PFSE3094 PFSE3044
1.5, 2 & 3HP • 1750 RPM • 60 Hz Submersible Sewage Pumps
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
ISP No: PFSE3 - 6/08 - rev 2
Page 2
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3039, 3044 Sewage Pumps
General Safety Information
Before installation, read the following instructions carefully. Failure to follow instruction and Safety information could cause serious bodily injury, death and/or property damage. Each Power-Flo pump is individually factory tested to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
• Risk of electric shock. To reduce risk of electric shock, always disconnect pump from power source before handling. Lock out power & tag.
• Keep clear of suction and discharge openings.
• Do not insert  ngers in pump with power connected.
• Always wear eye protection when working on pumps.
• Ground Fault Circuit Interrupter (GFCI) to be used with plug-in type power cord.
• Pumps build up heat and pressure during operation-allow time for pumps to cool before handling or servicing.
• This pump is not intended for use in swimming pools or water installations where human contact with pumped  uid.
• Installation must be in accordance with the National Electric Code and all
applicable state and local codes.
• Installation and servicing is to be conducted by quali ed personnel.
• These pumps are NOT to be installed in locations classi ed as hazardous in accordance with the National Electric Code, ANSI/NFPA 70.
Model Number
MFG Date
AMPS VOLTAGE
PHASE
60 Hz HP
• Do not us these pumps in water over 104˚F. Consult Power-Flo for high temperature pump models.
• The Uniform Plumbing Code (UPC) states that sewage systems shall have an audio and visual alarm that signals a malfunction of the systems that is required to reduce the potential for property damage.
IMPORTANT!
Prior to installation, record Model Number, MFG Date, Amps, Voltage, Phase and HP, from pump name plate for future reference. Also record the Voltage and Current Readings at Startup:
1 Phase Models 3 Phase Models
Amps: Amps L1-2: Volts L1-2:
Volts: Amps L2-3: Volts L2-3:
Amps L3-1: Volts L3-1:
877-24 PUMPS
www.powerflopumps.com
® Power-Flo is a registered trademark of Power-Flo Technologies Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. Alteration Rights Reserved. 3/08
2
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 3
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
DISCHARGE 3” NPT Female, Vertical bolt on flange
LIQUID TEMPERATURE 104°F Continuous
MOTOR HOUSING Cast Iron, Class 30
VOLUTE Cast Iron, Class 30
IMPELLER 2 vane open type, Cast Iron, Class 30
SOLIDS HANDLING 2-1/2” spherical
SHAFT Stainless steel
SEALPLATE Cast Iron, Class 30
SQUARE RINGS Buna-N
HARDWARE Stainless steel
SEAL Inboard, Single mechanical, Oil Filled
Silicon Carbide
UPPER BEARING Single row, ball, oil lubricated
LOWER BEARING Single row, ball, oil lubricated
POWER CORD 25 Ft. Cord. Pressure grommet for sealing and
strain relief
Speci cations
MOTOR Class B, Oil Filled
Single Phase - Permanant split capacitor
Includes overload protection in motor. Three Phase - 230/460 Volt. Requires overload protection to be included in control panel.
MODEL HP Volt/PH Hz
PFSE1524 1.5 230/1 60 1750 B 12.5 23.1 10/3 SOW 0.690
PFSE1594 1.5 200-230/3 60 1750 H/L 8.7/8.0 30.3/36.0 10/4 SOW 0.750
PFSE1544 1.5 460/3 60 1750 L 4.0 17.4 10/4 SOW 0.750
PFSE2024 2.0 230/1 60 1750 B 14.4 29.1 10/3 SOW 0.690
PFSE2094 2.0 200-230/3 60 1750 J/M 15.3/14.0 44.0/50.8 10/4 SOW 0.750
PFSE2044 2.0 460/3 60 1750 M 7.1 25.4 10/4 SOW 0.750
PFSE3024 3.0 230/1 60 1750 A 28.1 59.1 10/3 SOW 0.690
PFSE3094 3.0 230/3 60 1750 D 19.2 56.0 10/4 SOW 0.750
PFSE3044 3.0 460/3 60 1750 D 9.0 28.1 10/4 SOW 0.750
Winding resistance ± 5% at terminal block. Rated operation at ± 10% voltage at motor
RPM
(Nom)
NEMA
Start Code
Full Load
Amps
Locked
Rotor Amps
Cord Size Cord Type Cord O.D
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
3
Page 4
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Dimensions
For Models: PFSE1594, 1544, 2094 & 2044
For Models: PFSE1524, 2024, 3094, 3034, 3044
4
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 5
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Performance
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
5
Page 6
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Receiving & Installation
Receiving Inspection
Upon receiving the pump, it should be inspected for damage or shortages. If damage has occurred, le a claim immediately with the company that delivered the pump. If the manual is removed from the packaging, do not lose or misplace.
Storage
Any product that is stored for a period longer than six (6) months from the date of purchase should be bench tested prior to installation. A bench test consists of, checking the impeller to assure it is free turning and a run test to assure the motor (and switch if provided) operate properly. Do not pump out of liquid.
Controls
Manual models require a separate approved pump control device or panel for automatic operation. Be sure the electrical speci cation of the control selected properly match the electrical speci cations of the pump.
Submergence
The pump should always be operated in the submerged condition. The minimum sump liquid level should never be less than above the pump’s volute (See Figure 1).
Installation
These pumps are recommended for use in a sump, basin or lift station.
The sump, basin or lift station shall be sealed and vented in accordance with local plumbing codes. This pump is
designed to pump sewage, e uent or wastewater, nonexplosive and noncorrosive liquids and shall NOT be installed in locations classi ed as hazardous in accordance with the National Electrical Code (NEC) ANSI/ NFPA 70 or Canadian Electric Code (CEC). The pump should never be
installed in a trench, ditch, or hole with a dirt bottom. The legs will sink into the dirt and the suction will become plugged.
The installation should be at a su cient depth to ensure that all plumbing is below the frost line. If this is not feasible, remove the check valve and size the basin to accommodate the additional back ow volume.
Pumps are most commonly installed in simplex or duplex stations or basins with a slide rail system, which allows the pump(s) to be installed or removed without requiring personnel to enter the station, or resting on the basin  oor.
Liquid Level Controls
The level control(s) should be mounted on the discharge piping, a cable rack or  oat pole. The level control should have adequate clearance so it cannot hang up in it’s swing and that the pump is completely submerged when the level control is in the “O ” mode. By adjusting the cord tether the control level can be changed. One cycle of
operation should be observed, so that any potential problems can be corrected.
It is recommended that the level control  oat should be set to insure that the liquid in the sump never drops below the top of the motor housing or a minimum level of 10 inches above the basin  oor.
Electrical Connections
Power cable:
The power cable mounted to the pump must not be modied in any way except for shortening to a specic application. Any splice between the pump and the control panel must be made in accordance with the electric codes. It is recommended that a junction box, if used, be mounted outside the sump or be of at a minimum Nema 4 construction if located within the wet well. DO NOT USE
THE POWER CABLE TO LIFT PUMP.
Recommended Submergence Level
Minimum Submergence Level
10”
Bottom of Feet
Figure 1
6
Discharge Piping
Discharge piping should be as short as possible and sized no smaller than the pump discharge. Do not reduce
the discharge pipe size below that which is provided on the pump. Both
a check valve and a shut-o valve are recommended for each pump. The check valve is used to prevent backow into the sump. The shut-o valve is used to manually stop system ow during pump servicing.
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Always rely upon a Certi ed Electrician for installation.
Overload Protection: Single Phase - The stator in-winding
overload protector used is referred to as an inherent overheating protector and operates on the combined e ect of temperature and current. This means that the overload protector will trip out and shut the pump o if the windings become too hot, or the load current passing through them becomes too high.
Page 7
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Installation & Service
IMPORTANT ! - The overload will then
automatically reset and start the pump up after the motor cools to a safe temperature. In the event of an overload, the source of this condition should be determined and corrected immediately.
WARNING! - DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS !
If current through the temperature sensor exceeds the values listed, an intermediate control circuit relay must be used to reduce the current or the sensor will not work properly.
TEMPERATURE SENSOR ELECTRICAL
RATINGS
Volts Continuous
Amperes
110-120 3.00 30.0
220-240 1.50 15.0
440-480 0.75 7.5
600 0.60 6.0
Wire Size:
If longer power cable is required consult a quali ed electrician for proper wire size.
Inrush
Amperes
Pre-Operation
1. Check Voltage and Phase - Compare the voltage and phase information stamped on the pump name plate.
2. Check Pump Rotation - Improper motor rotation can result in poor pump performance and can damage the motor and/or pump. Check rotation on three phase units by momentarily applying power and observe the “kickback”.
Kickback should always be in a counter-clockwise direction as viewed from motor end or opposite to impeller rotation. Incorrect rotation for Single-Phase pumps is unlikely. If the rotation is incorrect contact factory.
3. Name Plate - Record the information from the pump name plate to drawing in front of manual for future reference.
4. Insulation Test - An insulation (megger) test should be performed on the motor. Before the pump is put into service. The resistance values (ohms) as well as the voltage (volts) and current (amps) should be recorded.
5. Pump-Down Test - Be sure pump has been properly wired, lowered into the basin, sump or lift station, check the system by lling with liquid and allowing the pump to operate through its pumping cycle. The time needed to empty the system, or pump-down time along with the volume of water, should be recorded.
Maintenance
No lubrication or maintenance is required. Perform the following checks when pump is removed from operation or when pump performance deteriorates: a). Inspect motor chamber for oil level and contamination. b). Inspect impeller and body for excessive build-up or clogging. c). Inspect motor, bearings and shaft seal for wear or leakage.
Servicing
NOTE: Item numbers in ( ) refer to Figures 6 through 9.
Cooling Oil - Anytime the pump is removed from operation, the cooling oil in the motor housing should be checked visually for oil level and contamination. To check oil, set unit upright. Remove pipe plug (20) from housing (4). With a ashlight, visually inspect the oil in the housing (4) to make sure it is clean and clear, light amber in color and free from suspended particles. Milky white oil indicates the presence of water. Oil level should be just above the motor when pump is in vertical position.
Oil Testing
• Drain oil into a clean, dry container by placing pump on it’s side, remove pipe plug (20), from housing (4).
• Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown.
• If oil is found to be clean and uncontaminated (measuring above 15 KV. breakdown), rell the housing.
• If oil is found to be dirty or contaminated (or measures below 15 KV. breakdown), the pump must be carefully inspected for leaks at the shaft seal, cable assembly, square ring and pipe plug, before relling with oil. To locate the leak, perform a pressure test.
After leak is repaired, dispose of old oil properly, and rell with new oil.
Pressure Test (If oil has been drained)
Remove pipe plug (20) from housing (4). Apply pipe sealant to pressure gauge assembly and tighten into hole. Pressurize motor housing to 10 P.S.I. Use soap solution around the sealed areas and inspect joints for “air bubbles”.
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
7
Page 8
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Service
If, after ve minutes, the pressure is still holding constant, and no “bubbles” are observed, slowly bleed the pressure and remove the gauge assembly. Replace oil. Leek must be located and repaired if pressure does not hold.
Pressure Test (If oil has NOT been drained) - Oil should be at normal level.
Remove pipe plug (20) from housing (4). Apply pipe sealant to pressure gauge assembly and tighten into hole. Pressurize motor housing to 10 P.S.I. Use soap solution around the sealed areas above the oil level and inspect joints for “air bubbles”. For sealed areas below oil level, leeks will seep oil. If, after ve minutes, the pressure is still holding constant, and no “bubbles” /oil seepage is observed, slowly bleed the pressure and remove the gauge assembly. Replace oil. Leek must be located and repaired if pressure does not hold.
Oil Replacement - Set unit upright and rell with new cooling oil as per table below . Fill to just above motor, but below capacitor as an air space must remain in the top of the housing to compensate for oil expansion. Apply pipe thread compound to threads of pipe plug (20) then assemble to housing (14.
DO NOT overll oil. Overlling of housing with oil can create
excessive and dangerous hydraulic pressure which can destroy the pump and create a hazard.
Overlling oil voids warranty.
Cooling Oil
Recommended Supplier/Grade
BP Enerpar SE100 Conoco Pale Parafn 22 Mobile D.T.E. Oil Light Shell Canada Transformer-10 Texaco Diala-Oil-AX
5. Remove washer (15) and v-gasket (16) and remove if damaged.
Power Cord - PFSE1594, 2094, 2044:
6. Remove gland nut (23), friction ring (24), grommet (25) and friction ring (24) from motor housing (4). Pull cord through and disconnect the wires from the terminals (28).
Power Cord - PFSE1524, 2024, 3024, 3094 & 3044
7. Remove cap screws (36) and washers (37), lift conduit box and cable assy (33) from motor housing (4). Disconnect the wires from the terminals (28). Remove o-ring (35) replace if damaged.
Motor & Capacitor:
8. Remove screws (17) and lift motor housing (4) from seal plate (3).
9. Remove o-ring (18), replace if damaged.
Figure 2
Pressure builds up extremely fast, increase pressure by
“TAPPING” air nozzle. Too much pressure will damage seal. DO
NOT exceed 10 P.S.I.
Disassembly
Impeller and Volute:
1. Disconnect power.
2. Remove hex nuts (9), vertically lift motor housing and seal plate assembly from volute (1). Clean out volute if necessary.
3. Inspect o-ring (19) and replace if cut or damaged.
4. Clean and examine impeller (2), for cracks or breakage and replace if required. To remove impeller (2), remove impeller nut (12) and washer (13). With a wheel puller, pull impeller straight o shaft and remove key (14).
10. Remove motor bolts, lift motor stator assembly from seal plate (3).
11. On Single Phase units only. Check motor capacitor (34) with an Ohm meter by rst grounding the capacitor by placing a screwdriver across both terminals and then removing screwdriver. Connect Ohm meter (set on high scale) to terminals. If needle moves to innity (∞) then drifts back, the capacitor is good. If needle does not move or moves to innity (∞) and does not drift back, replace capacitor (34).
12. Inspect motor winding for shorts and check resistance values. Check rotor for wear. If rotor or the stator windings are defective, the complete motor must be replaced.
8
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 9
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Service
Shaft Seal:
13. Unscrew conduit bushing (29) from seal plate (3) and lift motor rotor, shaft, bearing (8), rotating member of seal (6), washer (30) and conduit bushing (29) from seal plate (3). See Figure 3.
14. Remove seal parts (6) from shaft. Examine all seal parts, if seal faces show signs of wear, uneven wear pattern, chips or scratches replace entire seal. DO NOT
interchange seal components, replace the entire shaft seal (6). If replacing seal,
remove stationary from seal plate (3) by prying out with at screwdrive.
Reassembly:
IMPORTANT! - All parts must be clean before reassembly. Handle seal parts with extreme care. DO NOT damage lapped surfaces.
Shaft Seal:
1. To reassemble, clean seal cavity in seal plate (3) and oil.
2. Press seal’s (6) stationary member rmly into seal plate (3), use a seal tool or pipe. Nothing should come in contact with the seal face except the seal tool. Be sure the stationary is in straight.
3. Place conduit bushing (29) and washer (30) onto shaft. Press lower bearing (8) onto shaft.
4. Place seal’s (6) retaining ring and spring onto shaft. Lightly oil (Do not use grease) shaft and inner surface of bellows.
5. With lapped surface of rotating member facing outward, slide over shaft using a seal tool, being carefull not to damage seal face. Make sure spring is seated in retaining ring and spring is lined up on rotating member and not cocked or resting on bellows tail.
Bearing & Motor:
6. Slide rotor/shaft with bearing (8) and seal parts (6) into seal plate (3) until bearing seats into seal plate and tighten conduit bushing (29) into seal plate (3). Place stator over rotor, lining up motor bolts with holes in seal plate (3). Insert motor bolts and torque to 17 inch pounds.
7. On Single phase units, connect capacitor (34) to motor wires. See Figure 5.
8. On models PF1594, 2094 & 2044, place gland nut (23), one friction ring (24), grommet (25) and one friction ring (24) onto cord (22) and slide cord through hole in motor housing (4) (See Figure 4). Make wire connections per Figure 5.
9. On models PFSE1524, 2024, 3024, 3094 & 3044, place all motor leads above motor. Place o-ring (18) on seal plate (3) and lower motor housing (4) onto seal plate (3).
10. Place socket head screws (17) through seal plate into motor housing and torque to 60 inch pounds.
Impeller & Volute:
11. Install v-gasket (16) and impeller washer (15) over shaft, and into seal plate (3).
12. Install impeller (2) by appling a thin  lm of oil to motor shaft and slide impeller straight onto shaft, keeping keyways lined up. Drive key (14) into keyway.
Figure 3
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
13. Place washer (13) and impeller nut (12) onto shaft and torque to 40 ft lbs. Rotate impeller to check for binding.
14. Place o-ring (19) onto volute (1).
15. Lower motor housing and seal plate assembly onto volute (1). Apply thread locking compound to studs (9) and place hex nuts (4) onto studs and torque to 24 ft. lbs.
9
Page 10
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Service
Models - PFSE1524, 2024, 3024, 3094 & 3044
16. Pull wires through large opening in motor housing (4) an connect wires with cord (22) in Conduit box (33) per schematic in Figure 5.
17. Re ll with cooling oil and place o-ring (35) and conduit box (33)onto motor housing (4). Place cap screws (36) and washers (37) through conduit box into motor housing and tighten to 16 ft lbs.
Figure 5 - 480 Volt AC, 3Ph
Models: PFSE1544, PFSE2044, PFSE3044
Figure 4
Cable Assembly:
18. For ALL Models - Check power cord (22) for cracks or damage and replace
if required. Insert one friction ring (24), grommet (25), one friction ring (24), and gland nut (23) into motor housing (4) or conduit box & cable assembly (33) and torque gland nut (23) to 15 ft lbs.
19. on models PF1594, 2094 & 2044, re ll with with cooling oil and replace pipe plug (20).
Figure 5 - 120/240 Volt AC, 1Ph
Models: PFSE1524, PFSE2024, PFSE3024
Power Cable Motor Lead Number Green (Ground) Green Black 1 White 2 Flag Terminal Capacitor Flag Terminal Capacitor
Figure 5 - 200/240 Volt AC, 3Ph
Models: PFSE1594, PFSE2094, PFSE3094
Power Cable Motor Lead Number Green (Ground) Green Black 1 & 7 Red 2 & 8 White 3 & 9 4, 5 & 6 Together
Power Cable Motor Lead Number Green (Ground) Green Black 1 Red 2 White 3 4 & 7 Together 5 & 8 Together 6 & 9 Together
10
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 11
PFSE1594, 1544, 2094, 2044 Sewage Pumps
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Repair Parts
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Figure 6
11
Page 12
PFSE1594, 1544, 2094, 2044 Sewage Pumps
Repair Parts
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
12
Figure 7
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 13
PFSE1594, 1544, 2094, 2044 Sewage Pumps
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Ref.
No.
Qty Description Part Numbers
PFSE1594 PFSE1544 PFSE2094 PFSE2044
1 1 Volute PF03090081 PF03090081 PF03090081 PF03090081
21
3 1 Seal Plate PF03180012 PF03180012 PF03180012 PF03180012
4 1 Motor Housing PF03100002 PF03100002 PF03100002 PF03100002
5 1 Discharge Flange PF03060014 PF03060014 PF03060014 PF03060014
6 1 Shaft Seal - Silicon Carbide PF31030152 PF31030152 PF31030152 PF31030152
7 2 Motor #119 PF40040005 PF40040005 PF40040005 PF40040005
8 1 Ball Bearing PF31020010 PF31020010 PF31020010 PF31020010
9 4 Stud 3/8-16 x 2” Lg , Stainless
10 4 Hex Nut 3/8-16, Stainless
11 1 Gasket PF92010125 PF92010125 PF92010125 PF92010125
12 1 Impeller Nut 5/8-18, Stainless PF91010442 PF91010442 PF91010442 PF91010442
13 1 Washer 5/8, Stainless PF91010063 PF91010063 PF91010063 PF91010063
14 1 Shaft Key PF91010111 PF91010111 PF91010111 PF91010111
15 1 Washer, Impeller PF91010051 PF91010051 PF91010051 PF91010051
16 1 V-Gasket PF92010112 PF92010112 PF92010112 PF92010112
17 2 Soc. Hd Cap Screw 1/4-20 x 1” Lg, Stainless 18 1 O-ring PF92010083 PF92010083 PF92010083 PF92010083 19 1 O-ring PF92010082 PF92010082 PF92010082 PF92010082 20 1 Pipe Plug 3/4” NPT 21 1 Eye Bolt 1/2-13 x 1” Lg. 22 1 Power Cable, 25 Ft. PF31030003 PF31030003 PF31030003 PF31030003 23 1 Gland Nut PF30400903 PF30400903 PF30400903 PF30400903 24 2 Friction Ring PF91010055 PF91010055 PF91010055 PF91010055 25 1 Grommet PF92010001 PF92010001 PF92010001 PF92010001
26
27 1 Eye terminal 3/16” 28 3 Terminal Connector PF94010027 PF94010027 PF94010027 PF94010027 29 1 Conduit Bushing PF31190021 PF31190021 PF31190021 PF31190021 30 1 Washer Bushing PF91010054 PF91010054 PF91010054 PF91010054 31 2 Screw 1/2-13 x 1.75” Lg, Stainless 32 1 Lockwasher 1/2” Stainless 38 6 Female Connector PF94010041 PF94010041 PF94010041 PF94010041 39 1.5gal Cooling Oil Aquire locally - See chart on Page 8
Impeller - 6.25” Dia PF03140029 PF03140029 ---- ----
Impeller - 7.00” Dia ---- ---- PF03140029 PF03140029



 
1 Wire Connector PF94010012 ---- PF94010012 ---­3 Wire Connector ---- PF94010012 ---- PF94010012

 
Parts List
= Aquire standard hardware locally.
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
13
Page 14
PFSE1524, 2024, 3024, 3094, 3044 Sewage Pumps
Repair Parts
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
14
Figure 8
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 15
PFSE1524, 2024, 3024, 3094, 3044 Sewage Pumps
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Parts List
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Figure 9
15
Page 16
PFSE1524, 2024, 3024, 3094, 3044 Sewage Pumps
Parts List
Ref.
No.
Qty Description Part Numbers
1 1 Volute PF03090081 PF03090081 PF03090081 PF03090081 PF03090081
21
3 1 Seal Plate PF03180012 PF03180012 PF03180012 PF03180012 PF03180012
4 1 Motor Housing PF03100009 PF03100009 PF03100009 PF03100009 PF03100009
5 1 Discharge Flange PF03060014 PF03060014 PF03060014 PF03060014 PF03060014
6 1 Shaft Seal - Silicon Carbide PF31030152 PF31030152 PF31030152 PF31030152 PF31030152
7 2 Motor PF40040005 PF40040005 PF40040025 PF40040006 PF40040006
8 1 Ball Bearing PF31020010 PF31020010 PF31020010 PF31020010 PF31020010
9 4 Stud 3/8-16 x 2” Lg , Stainless
10 4 Hex Nut 3/8-16, Stainless
11 1 Gasket PF92010125 PF92010125 PF92010125 PF92010125 PF92010125
12 1 Impeller Nut 5/8-18, Stainless PF91010442 PF91010442 PF91010442 PF91010442 PF91010442
13 1 Washer 5/8, Stainless PF91010063 PF91010063 PF91010063 PF91010063 PF91010063
14 1 Shaft Key PF91010111 PF91010111 PF91010111 PF91010111 PF91010111
15 1 Washer, Impeller PF91010051 PF91010051 PF91010051 PF91010051 PF91010051
16 1 V-Gasket PF92010112 PF92010112 PF92010112 PF92010112 PF92010112
17 2 Soc. Hd Cap Screw 1/4-20 x 1” Lg, Stainless
18 1 O-ring PF92010083 PF92010083 PF92010083 PF92010083 PF92010083
19 1 O-ring PF92010082 PF92010082 PF92010082 PF92010082 PF92010082
20 1 Pipe Plug 3/4” NPT
21 1 Eye Bolt 1/2-13 x 1” Lg.
22 1 Power Cable, 25 Ft. PF31030003 PF31030003 PF31030003 PF31030003 PF31030003
23 1 Gland Nut PF30400903 PF30400903 PF30400903 PF30400903 PF30400903
24 2 Friction Ring PF91010055 PF91010055 PF91010055 PF91010055 PF91010055
25 1 Grommet PF92010001 PF92010001 PF92010001 PF92010001 PF92010001
26
27 1 Eye terminal 3/16”
28
29 1 Conduit Bushing PF31190021 PF31190021 PF31190021 PF31190021 PF31190021
Impeller - 6.25” Dia PF03140029 PF03140029 ---- ---- ----
Impeller - 7.00” Dia ---- ---- PF03140029 PF03140029 PF03140029
2 Wire Connector PF94010012 PF94010012 PF94010012 ---- ----
3 Wire Connector ---- ---- ---- PF94010012 PF94010012
2 Terminal Connector PF94010027 PF94010027 PF94010027 ---- ----
3 Terminal Connector ---- ---- ---- PF94010027 PF94010027
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
PFSE1524 PFSE2024 PFSE3024 PFSE3094 PFSE3044
 

 

16
= Aquire standard hardware locally.
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 17
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3034, 3044 Sewage Pumps
For Repair Part Please supply: Model Number and MFG Date as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Ref.
No.
30 1 Washer Bushing PF91010054 PF91010054 PF91010054 PF91010054 PF91010054
31 2 Screw 1/2-13 x 1.75” Lg, Stainless
32 1 Lockwasher 1/2” Stainless
33 1 Conduit Box & Cable Assy. PF03100010 PF03100010 PF03100010 PF03100010 PF03100010
34 1 Capacitor, 45 MFD 370V PF31030038 PF31030038 PF31030038 ---- ----
35 1 O-ring PF92010063 PF92010063 PF92010063 PF92010063 PF92010063
36 4 Cap screw 1/4-20 x 1” Lg Stainless
37 4 Lockwasher 1/4” Stainless
38
39 1.85gal Cooling Oil Aquire locally - See chart on Page 8
40 1 Pan Hd Screw 6-32 x .375” Lg
Qty Description Part Numbers
PFSE1524 PFSE2024 PFSE3024 PFSE3094 PFSE3044
 
 
8 Female Connector PF94010041 PF94010041 PF94010041 ---- ----
6 Female Connector ---- ---- ---- PF94010041 PF94010041

Parts List
= Aquire standard hardware locally.
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
17
Page 18
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Trouble Shooting Chart
Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.
Symptom Possible Cause(s) Corrective Action
1. Poor electrical connection, blown fuse, tripped breaker or other interruption of power; improper power supply
2. Motor or switch inoperative (go to manual
Pump will not run
Pump will not turn o
Pump hums but doesn’t run
Pump delivers insu cient capacity
Pump cycles too frequently or runs periodically when  xtures are not in use
Pump shuts o and turns on independent of switch, (trips thermal overload protector). CAUTION! Pump may start unexpectedly. Disconnect power supply.
Pump operates noisily or vibrates excessively
NOTE: Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the  eld. Disassembly of the pumps or supplied accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty.
operation) 2a. Float movement restricted 2b. Switch will not activate pump or is defective 2c. Defective motor
3. Insu cient liquid level
2a. Float movement restricted 2b. Switch will not activate pump or is defective
4. Ecessive in ow or pump not properly sized for application
9. Pump may be air locked causing pump not to  ow
14. H-O-A switch on panel is in “HAND” position
1. Incorrect low voltage
8. Impeller jammed or loose on shaft, or inlet plugged
1. Incorrect low voltage
4. Ecessive in ow or pump not properly sized for application
5. Discharge restricted
6. Check valve partially closed or installed backwards
7. Shut-o valve closed
8. Impeller jammed or loose on shaft, or inlet plugged
9. Pump may be air locked causing pump not to  ow
10. Piping  xtures leaking or discharge before the nozzle
6. Check valve partially closed or installed backwards
11. Fixtures are leaking
15. Ground water entering basin
1. Incorrect low voltage
4. Ecessive in ow or pump not properly sized for application
8. Impeller jammed or loose on shaft, or inlet plugged
12. Excessive water temperature (internal protection only)
2c. Worn bearings, motor shaft bent
5. Debris in impeller cavity or broken impeller
10. Pumprunning backwards
13. Piping attachments to building structure too loose or rigid
1. Check all electrical connections for security. Have electrician measure current in motor leads, if current is within ± 20% of locked rotor Amps, impeller is probably locked. If current is 0, overload may be tripped. Remove power, allow pump to cool, then re-check current. 2a. Reposition pump or clean basin as required to provide adaquate clearance for  oat 2b. Disconnect level control. Set ohmmeter for a low rang, such as 100 ohms full scale and connect to level control leads. Actuate level control manually and check to see that ohmmeter shows zero ohms for closed switch and full scale for open switch. (Float Switch) 2c. Check winding insulation (Megger Test) and winding resistance. If check is outside of range, dry and re-check. If still defective, replace per service instructions.
3. Make sure liquid level is above the pump
4. Re-check all sizing calculations to determine proper pump size.
5. Check discharge line for restrictions, including ice if line passes through or into cold areas.
6. Remove and examine check valve for proper installation and freedom of operation
7. Open valve
8. Check impeller for freedom of operation, security and condition. Clean impeller cavity and inlet of any obstruction
9. Loosen union slightly to allow trapped air to escape. Verify that turn-o level of switch is set so that the suction is always  ooded. Clean vent hole
10. Check rotation. If power supply is three phase, reverse any two of three power supply leads to ensure proper impeller rotation
11. Repair  xtures as required to eliminate leakage
12. Check pump temperature limits and  uid temperature
13. Replace portion of discharge pipe with  exible connector or tighten existing piping.
14. Turn to automatic position
15. Check for leaks around basin inlet and outlets
18
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
Page 19
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
Notes:
Power-Flo Pumps & Systems • 877-24PUMPS • www.power opumps.com
19
Page 20
PFSE1524, 1594, 1544, 2024, 2094, 2044, 3024, 3094, 3044 Sewage Pumps
LIMITED WARRANTY
Manufacturer warrants, to the immediate purchaser and subsequent initial owner during the warranty period, every
new pump to be free from defects in material and workmanship under normal use and service, when properly used
and maintained, for a period of eighteen (18) months from date of manufacture or twelve (12) months from date
of installation (which ever comes  rst). The initial owner is the purchaser who  rst uses the pump after its initial
installation, or for non-permanent installation, the  rst owner who uses the pump. The date of installation shall be
determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must
accompany the returned pump. Product will be repaired, replaced or remanufactured at Manufacturer’s option.
No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product
failure, repair or replacement. This warranty does not apply to and there shall be no warranty for any material or
product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication,
neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with
Manufacturer’s installation instructions; that has been exposed to outside substances including but not limited
to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents,
etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in all pumping
applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied;
and we do not authorize any representative or other person to assume for us any other liability in connection
with our products. Contact Manufacturer at: 1-877-24PUMPS or www.power opumps.com, Attention: Customer
Service Department, to obtain any needed repair or replacement of part(s) or additional information pertaining
to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL
DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS
FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE
EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply
to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you speci c legal rights and you may also have
other rights which vary from state to state.