Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
FEATURES:
High di/dt Capability
High dv/dt Capability
Hermetic Ceramic Package
Excellent Surge and I2t Ratings
APPLICATIONS:
DC Power Supplies
ORDERING INFORMATION Motor Controls
SS Contactors
Select the complete 12 digit Part Number using the table below.
EXAMPLE: TCU428340HDH is a 2800V-3400A SCR with 250ma
IGT and standard 12 inch gate and cathode potential leads.
V
DRM-VRRM
I
tavg
Tq
I
GT
TCU4 2800 28 3400 34 0 H DH
2600
* Optional TM lead consist of 20AWG FEP insulated twisted pair wires 17.5 inches in
length with ¼" insulated fast-on terminals.
The TCU4 is a high voltage, high current
disc pack SCR employing a high di/dt
gate structure. This gate design allows
the SCR to be reliably operated at high
di/dt and dv/dt conditions in various
phase control applications.

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
Characteristic Symbol Rating Units
Average On-State Current, TC=70°C
I
T(Avg.)
3400 A
RMS On-State Current, TC=70°C
Average On-State Current, TC=54°C
I
T(Avg.)
4000 A
RMS On-State Current, TC=54°C
Peak One Cycle Surge Current, 60Hz, VR=0V I
TSM
80,000 A
Peak One Cycle Surge Current, 50Hz, VR=0V I
TSM
75,424 A
Fuse Coordination I2t, 60Hz I2t
2.67E+07
A2s
Fuse Coordination I2t, 50Hz I2t
2.84E+07
A2s
Critical Rate-of-Rise of On-State Current di/dt 200 A/us
Repetitive
Critical Rate-of-Rise of On-State Current di/dt 400 A/us
Non-Repetitive
Peak Gate Power, 100us
Operating Temperature Tj -40 to+125 °C
Storage Temperature
Approximate Weight 3.2 lb
1.45 Kg
Mounting Force 12,000-15,000 lbs
53 - 67 Knewtons
Information listed is based upon Powerex testing and projected ratings and is subject to change
without notice. Powerex makes no implicit or explicit claim to reliability, capability, performance or
suitability of this product for a users application. Powerex makes no guarantee of future
availability of this product.

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
Electrical Characteristics, Tj=25°C unless otherwise specified
Rating
Characteristic Symbol Test Conditions min typ max Units
Repetitive Peak Forward
Leakage Current
I
DRM
Tj=125°C, V
DRM
=Rated
250 ma
Repetitive Peak Reverse
Leakage Current
I
RRM
Tj=125°C, V
RRM
=Rated
250 ma
VTM Model, Low Level V
0
Tj=125°C 0.978 V
VTM = VO + r•I
TM
r
15% I
TM
- π•I
TM
0.112 mΩ
VTM Model, High Level V
0
Tj=125°C 1.012 V
VTM = VO + r•I
TM
r
π•I
TM
- I
TSM
0.1059 mΩ
VTM= A + B•Ln(ITM) +
B
15%ITM - I
TSM
0.140
C•(I
TM
) + D•(ITM)
½
C 0.000115
D -0.00500
Turn-On Delay Time
t
d
V
D
= 0.5•V
DRM
2.5 us
Turn-Off Time tq Tj=125°C 400 us
dv/dt = 20V/us to 80% V
DRM
dv/dt
(Crit)
dv/dt Tj=125°C Exp. Waveform 1000 V/us
I
GT
Tj=25°C VD = 12V
30 100 250 ma
Peak Reverse Gate Voltage
Characteristic Symbol Test Conditions min typ max Units
Thermal Resistance
Junction to Case
RΘ
jc
Double side cooled 0.007 0.008 °C/Watt
RΘ
cs
Double side cooled 0.0015 0.002 °C/Watt
ZΘ
jc
(t) =
Σ(A(N)•(1-exp(-t/Tau(N))))
where: N = 1 2 3 4
A(N) = 1.43E-04 9.08E-04 2.37E-03 4.60E-03
Tau(N) = 2.62E-03 2.31E-02 5.00E-01 8.00E+00

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
0.00
1.00
2.00
3.00
4.00
100 1000 10000 100000
VTM (V)
ITM (A)
Maximum On-State Voltage Drop
0.0E+00
2.0E-03
4.0E-03
6.0E-03
8.0E-03
1.0E-02
0.01 0.1 1 10 100
Thermal Impedance (
°C/Watt)
Time (sec)
MAXIMUM TRANSIENT THERMAL IMPEDANCE

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
0
1000
2000
3000
4000
5000
6000
7000
8000
0 500 1000 1500 2000 2500 3000 3500 4000
Pavg (Watts)
Iavg (A)
Maximum On-State Power Dissipation
Sinusoidal Waveform
60°
90°
120°
180°
0° 180° 360°
CONDUCTION ANGLE
75
85
95
105
115
125
0 500 1000 1500 2000 2500 3000 3500 4000
Tc (
°C)
Iavg (A)
Maximum Allowable Case Temperature
0° 180° 360°
CONDUCTION ANGLE

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
0 1000 2000 3000 4000 5000
Pavg (Watts)
Iavg (A)
Maximum On-State Power Dissipation
0° 180° 360°
CONDUCTION ANGLE
75
85
95
105
115
125
0 1000 2000 3000 4000 5000
Tc (
°C)
Iavg (A)
Maximum Allowable Case Temperature
0° 180° 360°
CONDUCTION ANGLE

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1 10 100
Form
Factor
Number of cycles
MULTI-CYCLE SURGE FORM FACTOR
ITSM(N) = ITSM(1~) • FF(N)
0
100
200
300
400
500
600
700
800
900
1000
1 10 100
RECOVERY CURRENT (A)
diR/dt Rate (A/us)
REVERSE RECOVERY CURRENT

Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 WWW.PWRX.COM 3400 Amperes 2800 Volts
0
5000
10000
15000
20000
25000
30000
1 10 100
RECOVERY CHARGE (uCoul)
diR/dt Rate (A/us)
REVERSE RECOVERY CHARGE