RS02
See Below
For
Alternatives
*Other lead code
options available
__
13/
RS03
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Fast Recovery
Powerex, Europe, S.A. 428 Avenue
G.
Durand, BP107, 72003
Le
Mans, France (43) 41.14.14 Rectifier
13
125 Amperes Average
1400 Volts
I
o
MARKING
CASE
NUMBER
R50
DIMENSIONS
All
DIMENSIONS
R502
__
13/R503
NOMINAL
__
13 (Outline Drawing)
Ordering Information:
Select the complete part number
Yoltage
Type
R502 200
(Standard
Polarity)
R503 1000
(Reverse
Polarity)
YRRM
(Yolts)
400
600
800 08
1200 12
1400
Code
02
04
06
10
14
IF(av)
........
++--+--1.055/26.80
ARE
you
desire from the following table:
Currenl
(A)
Code
125 13 0.7
ACROSS
.375-24
REfERENCE
(J1I8c)
flATS
UNf -2A
Recovery
Time
trr
Code
LS
MM
THO.
Case
00-8
Leads
Code
WA
R502
__
13/R503
__
13
Fast Recovery Rectifier
125 Amperes Average, 1400 Volts
Features:
D Fast Recovery Times
D Soft Recovery Characteristics
o Standard
Polarities
o
Flag
Terminals Available
and
Reverse
Lead and Stud Top
o High Surge Current Ratings
D High Rated Blocking Voltages
D Special Electrical Selection for
Parallel
D Glazed Ceramic Seal Gives
High Voltage Creepage
Strike Paths
Applications:
D Inverters
and
Series Operation
and
Leads
W A
o Choppers
D Transmitters
o Free Wheeling Diode
F-3
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Powerex, Europe, S.A.
R502
__
13/R503
__
13
428
Avenue
G.
Durand, BP107, 72003 Le Mans, France (43) 41.14.14
Fast Recovery Rectifier
125
Amperes Average,
1400
Volts
Absolute Maximum Ratings
Characteristics
RMS Forward Current
Average Forward Current
One-half Cycle Surge Current
2
t
1
(for Fusing), Times ~ 8.3 milliseconds
Temperature
Storage
Operating Temperature
Mounting Torque
Symbol
IF(rms)
IF(av)
IFSM
J2
t
T
stg
Tj
Electrical and Thermal Characteristics
Characteristics
Current -Conducting State Maximums
Forward Voltage Drop
Voltage - Blocking State Maximums
Repetitive Peak Reverse Voltage (Rated Limit) VRRM
Non-rep. Trans. Peak Rev. Voltage (Rated Limit) VRSM
Reverse Leakage Current, rnA peak IRRM
Symbol
Test
Conditions
V ~ 5.0msec
Tj at max.,
VRRM = Rated
__
13/R503
__
R502
195 Amperes
125 Amperes
2500 Amperes
26000 A2sec
-40 to +190
to +150
-40
120
__
13/R503
R502
13
__
13
2.5 Volts
1400 Volts
1600 Volts
45
Units
°C
°C
in-Ib
Units
rnA
Switching
Maximum Reverse Recovery Time
Thermal
Maximum Resistance, Junction to Case
Maximum Resistance, Case to
Sink (Lubricated)
Re(j-c)
Re(c-s)
IFM = 314A, tp = 40llsec,
diR/dt = 25A1llsec, T C = 25°C
0.7
0.28
0.12
J.lSec
°ClWatt
°ClWatt
F-4