Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Fast Recovery
See Below For Alternatives
*
*Other lead code options available
Powerex, Europe, S.A. 428 Avenue
G.
Durand, BP107, 72003
Le
Mans, France (43) 41.14.14 Rectifier
1000 Amperes Average 1600 Volts
r DIA.
TYP.
DEEP
TYP.
\
MARKING
I---~--B
,\
I
±
:
I
I
CASE
NU
MBER
NOMINAL
R7S
DIMENSIONS
ADIA.
ADIA. C
DIA.
;:1::
DIA.
\
CATHODE
\
: ;
l
ANODE
STRIKE
DISTANCE, .38
CREEPAGE
I
.,
~
1:=
j
I
LD
INCH
/9.6
DISTANCE' .58
Iollol
INCH / 14.7
IolIN. Iollol
MIN.
1
Scale
R7S2
__
10
Recovery
Fast 1000 Amperes Average, 1600 Volts
Rectifier
=
2"
R7S2
Ordering Information:
Select the complete part number you desire from the following table:
Type
R7S2
Example: Type R7S2 rated at 1000A average with VRRM
R
eeoverv Time = 2.0 usee, order as:
R I 7
__
10 (Outline Drawing)
VRRM
(Volts)
400 04 1000 10 2.0 600
800 1000 10 1200 12 1400 14 1600 16
Type
S I 2
I
Voltage
Code
06 08
Voltage
1
I
Current
IF(av)
(A)
2
Code
Current
1
I 0
Recovery
Time
trr
(Ilsec)
= 1600V,
I
I
Code
ES R7S
trr
ES 0
Case
Leads
Leads
I 0
Code
00
Features:
D Fast Recovery Times D Soft Recovery Characteristics D High Surge Current Ratings D Special Selection of trr and
available
Orr
D Low Thermal Impedance D Low Profile Package
Applications:
D Inverters
D Choppers D Transmitters D Free Wheeling Diode
F-59
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A.
R7S2
__
10
428
Avenue
G.
Durand, BP107, 72003
Le
Mans, France (43) 41.14.14
Fast Recovery Rectifier
1000 Amperes Average, 1600 Volts
Absolute Maximum Ratings
Characteristics Symbol RMS Forward Current Average Forward Current One-half Cycle Surge Current
2
t (for Fusing), Times = 8.3 milliseconds
1
2
1
t Package (for Times = 8.3 milliseconds)
Max. Storage Temperature Operating Temperature Mounting Force
IF(rms)
IF(av)
IFSM
2
t
1
2
1
t
T
stg
Tj
Electrical and Thermal Characteristics
Characteristics
Symbol
Test
Conditions
R7S2
__
10 1550 Amperes 1000
11,000 Amperes
504000 A2sec
6
50 x 10
-40 to +190
-40 to +150
2000 to 2400 Ibs
R7S2
10
--
Units
Amperes
A2sec
°C °C
Units
Current -Conducting Forward Voltage Drop
Voltage -Blocking Repetitive Peak Reverse Voltage (Rated Limit) Non-rep. Trans. Peak Rev. Voltage (Rated Limit) Reverse Leakage Current, rnA peak
Switching Maximum Reverse Recovery Time
Thermal Maximum Resistance, Junction to Case Maximum Resistance, Case to Sink (Lubricated)
State
State
Maximums
Maximums
VFM
VRRM VRSM
IRRM
trr
RO(j-c)
RO(c-s)
Tj = 25°C,V IFM = 1500A
$ 5.0msec
t
Tj at max., VRRM = Rated
IFM =1500, tp = 190 IlSec,
diR/dt = 25A1llsec, T C = 25°C
1.65 Volts
1400 Volts 1600 Volts
50
2.0
0.035 °ClWatt
0.020 °ClWatt
rnA