Powerex R602 __ 22, R603 __ 22 Data Sheet

R602
See Below For Alternatives
*
*Other lead code options available
R603
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Fast Recovery
Powerex, Europe, S.A.
428
Avenue
Durand, BP107, 72003
Le
Mans, France (43) 41.14.14 Rectifier
__ __
22/ 22
220 Amperes Average 1600 Volts
H
DIA.
HOLE
F
MARKING
R602
__
221R603
CASE
NUMBER
NOMINAL
__
R60
DIMENSIONS
ALL
22 (Outline Drawing)
STRIKE CREEPAGE
DIMENSIONS
'--H--+---1.245
DISTANCE' .48
DISTANCE' .48
ARE
REFERENCE
ACROSS
.750-16
INCH
INCH
/31.62
FLATS
UNF -2A
112.2
MM
112.2
MM
MM
MIN.
THO.
MIN.
Ordering Information:
Select the complete part number you desire from the following table:
Voltage
Type
R602 400 04 220 22 (Standard Polarity)
R603 1200 12 (Reverse Polarity) 1600 16
VRRM (Volls)
Code
600 06 800 08
1000 10
1400 14
'F(av)
(A)
Current
Code
Recovery
Time
Irr
(nsec)
500
Code
PS
Leads
Case
00-9
Code
VA
Scate.Z"
R602
__
22/R603
__
22
Fast Recovery Rectifier
220 Amperes Average, 1600 Volts
Features:
o Fast Recovery Times o Soft Recovery Characteristics o Standard and Reverse
Polarities
o Flag Lead and Stud Top
Terminals Available
o High Surge Current Ratings
o High Rated Blocking Voltages o Special Electrical Selection for
Parallel and Series Operation
o Glazed Ceramic Seal Gives
High
Voltage Creepage and
Strike Paths
o Special Selection
Characteristics
of
Recovery
Available
Applications:
o Inverters
Example: Type R602 rated at 220A average with VRRM = 1600V,
Recove Time
R 6 0 PS
= 500nsec, order as:
A
o Choppers
o Transmitters o Free Wheeling Diode
~
....
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A.
R602
__
221R603
__
22
428
Avenue
Durand, BP107, 72003
Le
Mans, France (43) 41.14.14
Fast Recovery Rectifier
220 Amperes
Average,
1600
Volts
Absolute Maximum Ratings
Characteristics
RMS Forward Current Average Forward Current One-half Cycle Surge Current 3
Cycle Surge Current
10 Cycle Surge Current
2
1
t (for Fusing), Times;::: 8.3 milliseconds Storage Temperature Operating Temperature Mounting Torque (Lubricated)
Symbol
IF(rms)
IF(av)
Electrical and Thermal Characteristics
Characteristics
Current - Conducting State Maximums
Forward Voltage Drop
Voltage - Blocking State Maximums
Repetitive Peak Reverse Voltage (Rated Limit) Non-rep. Trans. Peak Rev. Voltage (Rated Limit) Reverse Leakage Current,
mA
peak
Symbol
VRRM VRSM
IRRM
T
at max.,
j
Test
Conditions
t ~ 5.0msec
VRRM
= Rated
345 Amperes
220 3500 Amperes 2700
2100
51000
-40
to +190
-40
to
+150
360
2.75 Volts
1600
1800
50
Amperes
Amperes Amperes
Units
in-Ib
Units
Volts Volts
mA
Switching
Maximum Reverse Recovery Time
Maximum Reverse Recovery
Time
Thermal
Maximum Resistance, Junction to Case Maximum Resistance, Case to Sink (Lubricated)
Reverse Recovery Wave Form
t.+lb
ORR
=
di (HEel = I
dt tb
)
-2
- x I
(
RMIRECI
RMIRECI
R
(j-c)
9
R9(C-S)
IFM = 785A,
diR/dt = 25A1Jlsec, T C = 25°C
IFM = 785A,
diR/dt = 25A1Jlsec, T C = 150°C
t::
~
"-
u
o
C
.>l
N
~
II)
u
g
c
.g
u
C
:3
-,
Q)
g
"i
iO
E
~
..c
~
0
tp
tp
001
= 100Jlsec,
= 100Jlsec,
Transient
005
01
500
1.1
0.17
0.10
Thermal Impedance Vs. Time
"
~
~
,
I
,.
I.-
l".,.1li
....
05
1 5 1
Time,
1.
Seconds
~
~
nsec
Jlsec
°ClWatt °ClWatt
-
5 10
F-12
Loading...