PS12032
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
A
F
H
K
L
Y
X
2435 67
EE
J
1520 19 18 1617 1314 1112
22 2128 25 23
10
Z
AA
CC
HH
9
8
JJ
GG
Z
FF
T
C
LABEL
T
C
KK
UU
"R" BB
"R" VV
RR (4
PLACES)
"R" AA
Q
PP
M
N
TERMINAL CODE
15 V
1 P2
16 UN
2 P1
17 WP
3 R
18 VP
4 S
19 UP
5 T
20 TH
6 N1
21 VD
7 N2
22 NC
8 U
23 CBW-
9 V
10 W
24 CBW+
25 CBV-
11 F
O
26 CBV+
AMP
12 V
13 GND
27 CBU-
14 WN
28 CBU+
C
N
B
N
"M" SQ PINS
P
R
Q
V
DED
G
X
S
U
T
1
W
LL
D
TT
SS
Intellimod™ Module
Application Specific IPM
5 Amperes/1200 Volts
Description:
Powerex Application Specific IPMs
(ASIPMs) are inteligent power
modules that integrate power
devices, gate drive and protection
circuitry in a compact package for
use in small inverter applications
up to 20kHz. Use of application
specific HVICs allow the designer
to reduce inverter size and overall
design time.
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 4.06 +0/-0.02 103.0+0/-0.4
B 2.87 +0/-0.02 73.0 +0/-0.4
C 0.35 9.0
D 0.10 2.5
E 3.11 79.0
F 3.74±0.01 95±0.2
G 1.32 33.5
H 0.95 24.0
J 0.87 22.0
K 0.08 2.0
L 0.24 6.0
M 0.02 Sq. 0.5 Sq.
N 2.72 69.0
P 2.13 54.0
Q 1.54±0.01 39.0±0.2
R 0.95 24.0
S 0.26 6.5
T 0.35 9.0
U 0.59 15.0
V 0.37 9.5
W 0.08 2.0
X 0.12 3.0
Dimensions Inches Millimeters
Y 1.81 46.0
Z 0.30 7.62
AA 0.08 Rad. 2.0 Rad.
BB 0.04 Rad. 1.0 Rad.
CC 0.14 3.5
DD 0.47 12.0
EE 1.20 30.48
FF 0.90 22.86
GG 0.30 7.62
HH 0.51 13.4
JJ 0.35 9.0
KK 0.34 8.5
LL 0.08 2.0
MM 0.12 3.0
NN 0.67 17.0
PP 0.49 12.5
QQ 0.80 20.4
RR 0.16 4.0
SS 0.06 1.4
TT 0.12 3.0
UU 0.04 1.0
VV 0.16 4.0
Features:
□ Rectifier Bridge for 3-phase
AC-to-DC Power Conversion
□ 3-phase IGBT Inverter Bridge
□ Integrated HVICs for Gate
Drive, Protection and
System Control Functions
□ Built-in Thermistor
□ Direct Connection to DSP/CPU
Applications:
□ Smart Motors
□ General Purpose Inverters
□ Small Motor Control
Ordering Information:
PS12032 is a 1200V, 5 Ampere
Application Specific Power Module.
71
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS12032
Intellimod™ Module
Application Specific IPM
5 Amperes/1200 Volts
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Characteristics Symbol PS12032 Units
Power Device Junction Temperature* T
Storage T emperature T
Case Operating Temperature (See TC Measure Point Illustration) T
j
stg
C
-20 to 125 °C
-40 to 125 °C
-20 to 100 °C
Mounting Torque, M3.5 Mounting Screws — 11.25 in-lb
Module Weight (Typical) — 127 Grams
Isolation Voltage** V
*The indicated values are specified considering the safe operation of all the parts within the ASIPM. The maximum rating for the ASIPM power chips (IGBT & FWDi) is Tj < 150.
**60 Hz sinusoidal AC applied between all terminals and the base plate for 1 minute.
ISO
2500 Volts
IGBT Inverter Sector
Supply Voltage (Applied between P2 - N2) V
Supply Voltage, Surge (Applied between P2 - N2, Surge-Value) V
Each IGBT Collector-Emitter Static Voltage (Applied between P2-U.V.W, U.V.W-N2) VP or V
Each IGBT Collector-Emitter Switching Voltage V
CC
CC(surge)
or V
P(S)
N
N(S)
(Applied between P2-U.V.W, U.V.W-N2 (Pulse))
Each IGBT Collector Current, TC = 25°C, “( )” means IC Peak Value ±IC (±ICP) ±5 (±10) Amperes
900 Volts
1000 Volts
1200 Volts
1200 Volts
Converter Sector
Repetitive Peak Reverse Voltage V
Recommended AC Input Voltage E
DC Output Current (3-phase Rectifying Circuit) I
Surge (Non-repetitive) Forward Current (1 Cycle at 60Hz, Peak Value Non-repetitive) I
RRM
a
O
FSM
I2t for Fusing (Value for One Cycle of Surge Current) I2t60A
1600 Volts
440 Vrms
12 A
120 A
2
s
Control Sector
Supply Voltage VD, V
Input Signal Voltage V
CIN
Fault Output Supply Voltage V
Fault Output Current I
DC-link IGBT Current Signal Amp Output Current I
FO
AMP
DB
FO
-0.5 ~ 20 Volts
-0.5 ~ 7.5 Volts
-0.5 ~ 7.5 Volts
15 mA
1mA
72
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS12032
Intellimod™ Module
Application Specific IPM
5 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage V
Diode Forward Voltage V
Converter Diode Voltage V
Converter Diode Reverse Current I
Switching Times t
FWDi Reverse Recovery Time t
CE(sat)
EC
FR
RRM
on
t
C(on)
t
off
t
C(off)
rr
Short-circuit Endurance (Output, Arm, and @VCC ≤ 800V, Input = 5V → 0V (One-shot), • No Destruction
Load Short-circuit Modes) -20°C ≤ T
Switching SOA @VCC ≤ 800V, Input = 5V → 0V, • No Destruction
IC = 5A, Tj = 25°C, VD = VDB = 15V, — — 3.6 Volts
Input = ON (Shunt Voltage Drop Not Included)
Tj = 25°C, -IC = 5A — — 3.5 Volts
Tj = 25°C, IFR = 5A — — 1.5 Volts
VR = V
, Tj = 125°C——8.0 mA
RRM
1/2 Bridge Inductive, Input = 5V ↔ 0V, 0.3 1.2 2.0 µS
VCC = 600V, IC = 5A, Tj = 125°C, — 0.5 1.4 µS
VD = 15V, VDB = 15V — 2.2 4.0 µS
Note: ton, t
include delay time of — 0.9 1.6 µS
off
the internal control circuit. — 0.2 — µS
≤ 125°C, • FO Output by Protection Operation
j(start)
13.5V ≤ VD = VDB ≤ 16.5V
Tj ≤ 150°C, IC < OC Trip Level, • No Protecting Operation
13.5V ≤ VD = VDB ≤ 16.5V • No FO Output
TC Measure Point
LABEL
T
C
T
C
73