Intellimod™ Module
Application Specific IPM
50 Amperes/600 Volts
Description:
Powerex Application Specific IPMs
(ASIPMs) are inteligent power
modules that integrate power
devices, gate drive and protection
circuitry in a compact package for
use in small inverter applications
up to 20kHz. Use of application
specific HVICs allow the designer
to reduce inverter size and overall
design time.
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 3.74±0.04 95.0±1.0
B 2.91±0.04 74.0±1.0
C 0.32 8.0
D 3.35±0.01 85.0±0.3
E 0.73 18.5
F 1.25 31.65
G 0.97 24.5
H 1.65 42.0
J 0.08 2.0
K 0.24 6.0
L 0.71 18.0
M 12.7 SQ. 0.5 SQ.
N 0.59 15.0
P 0.35 9.0
Q 2.32±0.01 59.0±0.3
R 1.38 35.0
S 0.10 2.5
Dimensions Inches Millimeters
T 2.80 71.0
U 3.23 82.1
V 0.04 1.0
W 0.14 3.5
X 2.00±0.03 50.8±0.8
Y 0.12 3.0
Z 0.14 3.5
AA 0.80±0.04 20.4±1.0
BB 0.12 3.0
CC 0.93 23.5
DD 1.21±0.02 30.7±0.5
EE 0.181 DIA. 4.6 DIA.
FF 0.197 DIA. 5.0 DIA.
GG 0.31±0.02 8.0±0.5
HH 0.67±0.03 17.0±0.8
JJ 0.16 4.0
KK 2.45±0.03 62.35±0.8
Features:
□ Compact Packages
□ 3 Phase Converter Bridge
Built-in
□ Integrated HVICs
□ Direct Connection to DSP/CPU
Applications:
□ Small Motor Control
□ Small Servo Motors
□ General Purpose Inverters
□ Pump and HVAC Motor Control
Ordering Information:
PS11037 is a 600V, 50 Ampere
Application Specific
Intelligent Power Module.
1
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS11037
Intellimod™ Module
Application Specific IPM
50 Amperes/600 Volts
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Characteristics Symbol PS11037 Units
Power Device Junction Temperature* T
Storage Temperature T
Case Operating Temperature (See TC Measure Point Illustration) T
j
stg
C
-20 to 125 °C
-40 to 125 °C
-20 to 100 °C
Mounting Torque, M4 Mounting Screws — 13 in-lb
Module Weight (T ypical) — 108 Grams
Isolation Voltage** V
*The indicated values are specified considering the safe operation of all the parts within the ASIPM. The maximum rating for the ASIPM power chips (IGBT & FWDi) is Tj < 150.
**60 Hz sinusoidal AC applied between all terminals and the base plate for 1 minute.
ISO
2500 Volts
IGBT Inverter Sector
Supply Voltage (Applied between P - N) V
Supply Voltage, Surge (Applied between P - N, Surge-Value) V
Each IGBT Collector-Emitter Static Voltage (Applied between P-U.V.W, U.V.W-N) VP or V
Each IGBT Collector-Emitter Switching Voltage V
CC
CC(surge)
or V
P(S)
N
N(S)
(Applied between P-U.V.W, U.V.W-N (Pulse))
Each IGBT Collector Current, TC = 25°C, “( )” means IC Peak Value ±IC (±ICP) ±50 (±100) Amperes
450 Volts
500 Volts
600 Volts
600 Volts
Control Sector
Supply Voltage VD, V
Input Signal Voltage V
Fault Output Supply Voltage V
Fault Output Current I
DC-Link IGBT Current Signal Amp Output Current I
CIN
FO
AMP
FO
DB
-0.5 ~ 20 Volts
-0.5 ~ 7.5 Volts
-0.5 ~ 7.5 Volts
15 mA
1mA
2