POWEREX PM600HSA120 Datasheet

PM600HSA120
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
A B
E E
S
K
H
C
N
H
M
S
V - DIA. (4 TYP.)
SEE FIGURE A
JG
F
E
C
P
W
12345
T - M8 THD
L
Y - (4 TYP.)
0.64 MM SQ. PIN (5 TYP.)
R
U
V1
1. SR
2. C1
3. VC
4. FO
5.
AA
D
Z
- DIA.
X
FIGURE A
- DIA.
Q
- DIA.
Intellimod™ Module
Half Phase IGBT Inverter Output 600 Amperes/1200 Volts
Description:
V1
FO SR C1 VC
FO SR IN
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 5.24 133.0 B 4.33±0.01 110.0±0.25 C 3.98 101.0 D 3.23±0.01 82.0±0.25 E 2.16 55.0 F 1.97 50.0 G 1.42 +0.04/-0.02 36.0 +1.0/-0.5 H 1.42 36.0
J 1.33 33.7 K 1.25 31.7 L 1.02 26.0 M 0.80 20.3 N 0.79 20.0
VCC
GND
C
TEMP OUT1 OUT2 SENS SINK
E
Dimensions Inches Millimeters
P 0.71 18.0 Q 0.41 10.5 R 0.37 9.5 S 0.35 9.0 T M8 Metric M8 U 0.28 7.0 V 0.26 Dia. Dia. 6.5
W 0.02 5.0
X 0.02 Dia. Dia. 5.0 Y 0.100 2.54 Z 0.09 Dia. Dia. 2.3
AA 0.04 Dia. Dia. 1.0
Features:
Complete Output Power
Circuit
Gate Drive CircuitProtection Logic
– Short Circuit – Over Current – Over Temper ature – Under V oltage
Applications:
InvertersUPSMotion/Servo ControlPower Supplies
Ordering Information:
Example: Select the complete part number from the table below
-i.e. PM600HSA120 is a 1200V, 600 Ampere Intellimod™ Intelligent Power Module.
Type Current Rating V
Amperes Volts (x 10)
PM 600 120
CES
683
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM600HSA120 Intellimod™ Module Half Phase IGBT Inverter Output
600 Amperes/1200 Volts
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Characteristics Symbol PM600HSA120 Units
Power Device Junction Temperature T Storage Temperature T Case Operating Temperature T
j
stg
C
-20 to 150 °C
-40 to 125 °C
-20 to 100 °C Mounting Torque, M6 Mounting Screws 26 in-lb Mounting Torque, M8 Main Terminal Screws 95 in-lb Module Weight (T ypical) 1090 Grams Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V, Inverter Part) V Isolation Voltage, AC 1 minute, 60Hz Sinusoidal V
CC(prot.)
RMS
800 Volts
2500 Volts
Control Sector
Supply Voltage Applied between (V1-VC)V Input Voltage Applied between (C1-VC)V Fault Output Supply Voltage (Applied between Fo-Vc)V Fault Output Current I
D
CIN
FO
FO
20 Volts 10 Volts 20 Volts 20 mA
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, V Collector Current, ± I Peak Collector Current, ± I Collector Dissipation P
= 5V) V
CIN
CES
C
CP
C
1200 Volts
600 Amperes 1200 Amperes 3470 Watts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Control Sector
Over Current Trip Level Inverter Part OC -20°C Tj 125°C 740 1000 Amperes Short Circuit Trip Level Inverter Part SC -20°C Tj 125°C 1000 1400 Amperes Over Current Delay Time t
off(OC)
Over Temperature Protection OT T rip Level 100 110 120 °C
OT
R
Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
UV
R
Supply Voltage V Circuit Current I Input ON Threshold Voltage V Input OFF Threshold Voltage V PWM Input Frequency f Fault Output Current I
Minimum Fault Output Pulse Width t SXR T erminal Output Voltage V
D
D CIN(on) CIN(off)
PWM
FO(H)
I
FO(L)
FO
SXR
VD = 15V, V
VD = 15V 5 µS
Reset Level 85 95 105 °C
Reset Level 12.5 Volts
Applied between V1-V
= 5V, V1-V
CIN
Applied between C1-V Applied between C1-V
C
C C C
13.5 15 16.5 Volts —2330mA
1.2 1.5 1.8 Volts
1.7 2.0 2.3 Volts
3-B Sinusoidal 15 20 kHz VD = 15V, VFO = 15V 0.01 mA VD = 15V, VFO = 15V 10 15 mA
VD = 15V 1.0 1.8 mS
Tj 125°C, Rin = 6.8 k 4.5 5.1 5.6 Volts