POWEREX CT25AS-8 Datasheet

MITSUBISHI INSULATED GATE BIPOLAR TRANSISTOR
CT25AS-8
STROBE FLASHER USE
¡VCES ................................................................................400V
¡I
CM ....................................................................................150A
OUTLINE DRAWING Dimensions in mm
0.9MAX.
2.3
q
5.0 ± 0.2
4
1.0MAX.
2.3
1
6.5
10MAX.
5.5 ± 0.2
1.0
2.3MIN. 1.5 ± 0.2
2.3
2
3
wr
q GATE w COLLECTOR e EMITTER r COLLECTOR
e
0.5 ± 0.1
0.5 ± 0.2
0.8
MP-3
APPLICATION
Strobe Flasher.
MAXIMUM RATINGS (Tc = 25°C)
Parameter ConditionsSymbol Ratings Unit VCES VGES VGEM ICM Tj Tstg
Collector-emitter voltage Gate-emitter voltage Peak gate-emitter voltage Collector current (Pulsed) Junction temperature Storage temperature
ELECTRICAL CHARACTERISTICS (Tj = 25°C)
Symbol UnitParameter Test conditions
V(BR)CES ICES IGES VGE(th)
Collector-emitter breakdown voltage Collector-emitter leakage current Gate-emitter leakage current Gate-emitter threshold voltage
VGE = 0V VCE = 0V, See notice 4 VCE = 0V, tw = 0.5s See figure 1
IC = 1mA, VGE = 0V VCE = 400V, VGE = 0V VGE = ±40V , VCE = 0V VCE = 10V, IC = 1mA
400
±30 ±40
150 –40 ~ +150 –40 ~ +150
Limits
Min. Typ. Max.
450
— — —
— — — —
— 10
±0.1
7.0
V V V A
°C °C
V
µA µA
V
Feb.1999
PERFORMANCE CURVES
MAXIMUM PULSE COLLECTOR CURRENT
200
(A)
CM
160
<
T
C
120
80
40
0
PULSE COLLECTOR CURRENT I
=
GATE-EMITTER VOLTAGE V
50°C
CM = 400µF
<
T
C
70°C
=
GE
MITSUBISHI INSULATED GATE BIPOLAR TRANSISTOR
CT25AS-8
STROBE FLASHER USE
504030100 20
(V)
APPLICATION EXAMPLE
IXe
R
G
V
G
IGBT
RECOMMEND CONDITION
CM
= 330V
V
P
= 130A
I
M
= 300µF
C
GE
= 28V
V
V
Figure 1
Vtrig
CE
MAXIMUM CONDITION 350V
150A 400µF
TRIGGER SIGNAL
C
M
+
V
CM
IGBT GATE VOLTAGE
Xe TUBE
Vtrig
V
Ixe
G
CURRENT
Notice 1. Gate drive voltage during on-period must be applied to satisfy the rating of maximum pulse collector current.
And reverse gate current during turn-off must be kept less than 1A. (In general, it is satisfied if RG 30Ω)
Notice 2. IGBT has MOS structure and its gate is insulated by thin silicon oxide.
So please handle carefully not to suffer from electrostatic charge.
Notice 3. The operation life should be endured 5,000 shots under the charge current
(Ixe 150A : full luminescence condition) of main condenser (CM=400µF). Repetition period under full luminescence condition is over 3 seconds.
Notice 4. Total operation hours must be applied within 5,000 hours.