SUGGESTED AIRE CURTAIN SPECIFICATIONS
MODEL CED
All aire curtains furnished are complete factory assembled units as manufactured by Powered Aire Inc. Greenville, PA. Each unit consists of a stainless steel casing, centrifugal fans, raised stainless steel inlet screen, discharge nozzle, motor(s), and an optional 1/2 inch recleanable filter. The aire curtain unit provides a specific CFM and a uniform velocity across the entire length of the discharge area.
Units shall be furnished in single increments of sufficient structural strength to be supported from both ends without intermediate support. Multiple units shall not be permitted. Unit casing shall be a minimum of 18 gauge 304 stainless steel in a number three finish.
Motors at 1/2 H.P. 1075 rpm each shall be heavy duty type equipped with permanently lubricated, shielded ball bearings of equal size at each end and double extended shafts requiring no outboard bearings. Primary motor voltage shall be 115/208/230/480/575 volts 50/60 Hz single phase.
Galvanized fans shall be forward curved centrifugal type, double inlet design, with zinc plated hubs. Tangential type blowers and coupling connection shall not be permitted. Inlet screen shall be perforated stainless steel with mill grain finish.
Discharge nozzle shall be high efficiency discharge plenum, designed so that the air leaves on a 6 degree plane. Aire curtain creates a positive air seal with directional air foil vane. The vane shall facilitate deflection of air stream + from maximum spee d.
Unit(s) shall be provided with a factory mounted electric heating element (capacities as shown on data sheet). The heater shall consist of a factory wired heating coil, with automatic reset thermal overloads. Heating elements shall be mounted inside the plenum, on the discharge side of the blowers (where heat can’t affect motor life). Protective screening will not be required on discharge nozzle. A remote or factory mounted heat on/off switch and thermostat available, please specify.
For steam or hot water heated aire curtains see Hot Water / Steam Heated section of catalog.
Consult factory for optional top air intake.
Aire Curtain unit shall be ETL or UL listed. Unheated units shall have a 24 month warranty on all parts. Heated units shall have an 18 month warranty on all parts.
20 degrees. Unit shall have multiple speed motor(s) to control air volume down
Electric Heat Option
Steam / Hot Water Coil
October, 2013
www.poweredaire.com)
Control Options for Model CED
Unheated
* Recommended
*Built-in Time Delay Relay -- Provides a delay for shutting off the air curtain after the door is shut. This is
useful for doors that see a lot of foot traffic, so the unit is not constantly turning on and off during the day. To be used in conjunction with a door switch.
*Door Switch/Magnetic -- A non-mechanical door switch that turns the air curtain on when the door is opened.
*High/Off/Low Selector Switch (Remote or Unit Mounted) -- Switches between the high and low speeds or turns the air curtain off.
Electrically Heated Options
* Recommended
*Built-in Time Delay Relay -- Provides a delay for shutting off the air curtain after the door is shut. This is
useful for doors that see a lot of foot traffic, so the unit is not constantly turning on and off during the day. To be used in conjunction with a door switch.
*Door Switch/Magnetic -- A non-mechanical door switch that turns the air curtain on when the door is opened.
*High/Off/Low Selector Switch (Remote or Unit Mounted) -- Switches between the high and low speeds or turns the air curtain off.
*Heat On/Off Selector Switch (Remote or Unit Mounted) -- Turns the electric heat on and off while the fans are running, or when used in conjunction with a thermostat can disable the heat.
*Thermostat (Remote or Unit Mounted) -- Turns the electric heat in the unit on and off while the fans are running based on the room temperature.
*Single Point Power Connection -- For units that would typically require more than one power source due to high amp draws according to the National Electric Code, branch fusing can be added so that the unit can be run from a single power source.
Other Options
Cruise Control Programmable Switch -- Digital logic controller with an LCD display that takes the place
of several individual control components including a Built-in Time Delay Relay, On/Off/Auto Switch, Heat On/Off Switch, High/Low Switch.
Disconnect-Fused -- A switch that will disconnect all power from the unit so that the unit can be serviced or inspected and includes fuses for circuit protection (single point power connection may be required).
Disconnect-Non Fused -- A switch that will disconnect all power from the unit so that the unit can be serviced or inspected (single point power connection may be required).
Door Switch/Roller-Plunger -- A mechanical door switch that turns the air curtain on when the door is opened.
Hand/Off/Auto Selector Switch (Remote or Unit Mounted) -- Switches between the unit running constantly in the hand position, off, and auto, which only runs when the door switch is activated.
Motion Detector -- Turns the air curtain on when the sensors detect motion so that the air curtain turns on before the door is opened.
On/Off Selector Switch (R emote or Unit Mounted) -- Switches the air curtain on and off.
Programmable Digital Thermostat -- A thermostat that is programmable with a digital display (7-day,
1/2 hour increments, specify up to 4 time periods per day).