Potterton Performa System HE User Manual

User’s Guide
Performa
System HE
This is a Wall Mounted Powered Flue Condensing Boiler Gas Fired Central Heating Unit.
The boiler meets the requirements of Statutory Instrument “ The Boiler (Efficiency) Regulations 1993 No3083” and is deemed to meet the requirements of Directive 92/42/EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels:-
Type test for purpose of Regulation 5 certified by: Notified Body 0051.
Product/Production certified by: Notified Body 0051.
For use in GB/IE only.
2
Publication No. 5111818
Natural Gas
Potterton Performa System 12 HE
G.C.No41 591 24
Potterton Performa System 18 HE
G.C.No41 591 25
Potterton Performa System 24 HE
G.C.No41 591 26
Potterton Performa System 28 HE
G.C.No41 591 27
IMPORTANT - Installation, Commissioning, Service & Repair
This appliance must be installed in accordance with the manufacturers instructions and the regulations in force. Read the instructions fully before installing or using the appliance.
In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations.
Definition of competence: A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules, is deemed competent.
In IE, this must be carried out by a competent person as stated in I.S. 813 Domestic Gas Installations”.
Lifting - This product should be lifted and handled by two people. Stooping should be avoided and protective equipment worn where necessary. Carrying & lifting equipment should be used as required, e.g. when installing in a loft space.
The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations.
Warning - Check the information on the data plate is compatible with local supply conditions.
Benchmark Commissioning Checklist
Please ensure that your installer hands you the boiler Installation & Service Instructions with the Benchmark Commissioning Checklist sections completed. The details in the Checklist will be required in the event of any warranty work. Keep the instructions in a safe place and ensure that the Service Interval Record at the back is completed at each service visit.
CORGI
All CORGI registered installers carry a CORGI identification card and have a registration number. You can check your installer is registered by telephoning 0870 4012300 or writing to:-
1 Elmwood,
Chineham Business Park,
Crockford Lane,
Basingstoke. RG24 8WG
or check online at www.corgi-gas-safety.com
This product has an energy rating (B) on a scale of A to G.
For more information see www.boilers.org.uk. This is a certification mark.
3
Publication No. 5111818
In an Emergency
If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows;
1. Turn off the electrical supply and turn the selector switch on the facia box to the Off position.
2. Using a suitable open ended spanner or screwdriver turn the square on the gas tap to the left to isolate the gas supply at the boiler (Fig. 1).
3. The isolating valves are positioned under the boiler and can be closed by turning their taps to the right towards the wall (Fig. 2).
4. Call your Installer or Service Engineer as soon as possible.
In case of gas leaks
1. If a gas leak is found or suspected, turn off the gas supply at the meter immediately and at the isolating valve on the boiler if possible. Contact your Gas Supplier immediately.
Servicing your Appliance
1. For reasons of safety and economy your appliance should be serviced annually. Servicing must be performed by a competent person. Your Installer or Service Engineer will be able to advise you.
2. Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction.
Electricity Supply
1. THIS APPLIANCE MUST BE EARTHED.
2. A standard 230V ~ 50Hz supply is required. The appliance must be protected by a 3 amp fuse.
Never Hang Flammable Items Over The Appliance
Gas Tap
Heating Flow and
Heating Return
Isolating Valves
Fig. 1
Fig. 2
4
Publication No. 5111818
Introduction
1. Your Potterton Performa System HE is a gas fired, room sealed, powered flue boiler, providing central heating and hot water for your home. It is fully automatic and does not have a pilot light.
2. Due to the high efficiency and resultant low flue gas temperature when in condensing mode a white plume of condensate will be emitted from the terminal. This will be particularly evident during periods of low outside temperature.
Facia Panel
1. The facia panel is behind the hinged lower door panel. As well as the On/Off/Reset selector switch, temperature control knob and pressure gauge, the facia incorporates nine neon indicator lights.
2. Neons 10, 11 & 12 indicate the operational status of the boiler. Neons 4 to 9 have a dual function, indicating the temperature of the central heating water when constantly illuminated. If a fault develops the appropriate neon will begin to flash.
2
1
0
4
3
bar
30° 40° 50° 60° 70° 80°
Reset
Fig. 3
30° 40° 50° 60° 70° 80°
1. On/Off/Reset Selector Switch
2. Temperature Control
3. Central Heating System Pressure Gauge
Neon Indicators
4. Flame Failure or Blocked Condensate Drain
5. Safety Thermostat Activated (Boiler or Flue)
6. Fault on Fan or Flue
7. Fault on Pump or Low System Pressure
8. Fault on Temperature Sensor
9. Fault on Temperature Sensor
10. Power On
11. Boiler On
12. Burner On
When neons 4 to 9 are constantly illuminated, they indicate the temperature of the central heating water.
213
456 7 9
10 12
8
11
KEY TO FACIA PANEL (Fig. 3)