Bellingham, WA 98225
U.S. Default Settings Sequence
Enter Setup
Reset Scanner
Enable Auto-Sense Mode ON
UPC-A Convert to EAN-13 OFF
UPC-E Lead Zero ON
Save Changes
Exit Setup without Changes
Table of Contents
Restore Default Settings.......................................................................................ii
Set Connection .................................................................................................... ..1
RF Auto Shutdown Duration...............................................................................1
Memory Mode Parameters............ ..................................... .................................2
List Setting................................................................................................ .............3
Buzzer Settings......................................................................................................3
Reading Redundancy Setting...................................................... .........................4
Scan Mode Setting........................................................................................ ........4
Auto-Sense Setting................................................................................................4
Scanner Time-out Duration.................................................................................5
Negative Barcode Setting.....................................................................................5
Delay between Reread..........................................................................................5
Keyboard Wedge Parameters..............................................................................6
Laptop Support.....................................................................................................8
RS-232 Parameters...............................................................................................9
Bluetooth Serial Port Parameters.......... ..................................... .......................11
Prefix / Postfix Settings.......................................................................................12
Character Substitution.................................................... ...................................12
Code ID Selection................................................................................................12
Code ID Setting...................................................................................................13
Length Code Setting (2 digits)...........................................................................14
Select Readable Codes........................................................................................17
Code39 Parameters.............................................................................................22
Italy Pharmacode Parameters ...........................................................................22
French Pharmacode Parameters.................................................................. .....23
Industrial 25 Parameters.................. ..................................................................23
Interleave 25 Parameters...................................................................................24
Matrix 25 Parameters.........................................................................................26
Codabar Parameters...........................................................................................27
Plessey Parameters............................................................ .................................28
Telepen Parameters............................................................................................28
MSI Parameters..................................................................................................29
MSI Parameters..................................................................................................29
EAN128 Parameters...........................................................................................30
EAN8 Parameters...............................................................................................31
UPCA Parameters.......................................................... .....................................31
UPCE Parameters...............................................................................................32
EAN13 Parameters.............................................................................................33
RSS Code ID Selection...................................................... .................................34
RSS14 Parameters.................................................. ............................................34
RSS Limited Parameters....................................................................................35
RSS Limited Parameters....................................................................................35
Activate Editing Formats...................................................................................36
Editing Format Parameters...............................................................................37
Decimal Digits.....................................................................................................49
Hexadecimal Digits.............................................................................................50
RS-232 Character Table....................................................................................51
1
Update
Set Connection
*
Programming Instructions : (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired 3660 Base Station within 5 seconds to complete this setting.
RF Auto Shutdown Duration
*
Programming Instructions : (1) Read the label. (2) Program the desi red auto shutdown duration (in minutes) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
2
Enter Setup
Memory Mode Parameters
Memory Mode
Enable
< Disable >
Clear Data
Clear
Confirm
Send Data
Memory Data Delay
< 0 >
2 sec
250 ms
3 sec
500 ms
5 sec
1 sec
8 sec
3
Update
List Setting
Page1
Page 6
Page 2
Page 7
Page 3
Page 8
Page 4
Page 9
Page 5
Page 10
Buzzer Settings
< Buzzer Enable>
Buzzer Disable
Buzzer Frequency
8 kHz
< 4 kHz >
2 kHz
1 kHz
4
Enter Setup
Reading Redundancy Setting
< No Redundancy >
2 Times
3 Times
4 Times
Scan Mode Setting
Auto Off Mode
< Continuous Mode >
Auto Power Off Mode
Alternate Mode
Momentary Mode
Repeat Mode
Laser Mode
Test Mode
Auto-Sense Setting
< Enable >
Disable
5
Update
Scanner Time-out Duration
*
Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Negative Barcode Setting
Enable
< Disable >
Delay between Reread
100 ms
1 sec
200ms
2 sec
< 400 ms >
3 sec
800 ms
5 sec
6
Enter Setup
Keyboard Wedge Parameters
Activate and Select Keyboard Type
*
Programming Instructions : (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
Keyboard Table
No. Keyboard Type
1 PCAT (US) 2 PCAT (French) 3 PCAT (German) 4 PCAT (Italy) 5 PCAT (Swedish) 6 PCAT (Norwegian) 7 PCAT (UK) 8 PCAT (Belgium)
9 PCAT (Spanish) 10 PCAT (Portuguese) 11 PS55 A01-1 12 PS55 A01-2 13 PS55 A01-3 14 PS55 001-1 15 PS55 001-81 16 PS55 001-2 17 PS55 001-82 18 PS55 001-3 19 PS55 001-8A 20 PS55 002-1, 003-1 21 PS55 002-81, 003-81 22 PS55 002-2, 003-2 23 PS55 002-82, 003-82 24 PS55 002-3, 003-3 25 PS55 002-8A, 003-8A 26 IBM 3477 (Japanese) 27 PS2-30 28 IBM 34XX/319X, Memorex Telex 122 Keys
7
Update
Keyboard Alphabets Layout
< Default Layout >
AZERTY
QWERTZ
Keyboard Digits Layout
< Default Layout >
Lower Row
Upper Row
Keyboard Capital Lock Type
< Default >
Shift Lock
Capital Lock
Capital Lock Setting
Capital Lock ON
< Capital Lock OFF >
Auto Detection
8
Enter Setup
Alphabet Transmission
< Case Sensitive >
Ignore Case
Digits Transmission
< Alphanumeric Key >
Numeric Key
Alt Composing
Yes
< No >
Inter-Character Delay
*
Programming Instructions : (1) Read the label. (2) Program the desired inter­character delay by reading Decimal Digits on page 49. (3) Read the “Val idate” label (also on page 49) to complete this setting.
Laptop Support
< Disable>
Enable
9
Update
RS-232 Parameters
Activate RS232 Interface
Baud Rate
115200
38400
19200
< 9600 >
4800
2400
1200
300
Parity
Even
Odd
< No Parity >
Data Bit
< 8 >
7
10
Enter Setup
Flow Control
< None >
Scanner Ready
Data Ready
INV. Data Ready
Inter-Character Delay
*
Programming Instructions : (1) Read the label. (2) Program the desired inter­character delay by reading Decimal Digits on page 49. (3) Read the “Val idate” label (also on page 49) to complete this setting.
11
Update
Bluetooth Serial Port Parameters
Activate BlueTooth Serial Port Interface
Device Name Broadcasting
< Yes >
No
Authentication
Yes
< No >
PIN Code
*
Programming Instructions : (1) Read the label. (2) Program the desi red character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting. (4) Max 6 characters for this PIN Code setting.
12
Enter Setup
Prefix / Postfix Settings
Prefix Code *
Postfix Code *
Character Substitution
Set 1 *
Set 2 *
Set 3 * Programming Instructions : (1) Read the label. (2) Program the desired character
string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
Code ID Selection
Clear All Code ID Settings
Select Code ID Set
Set 1
Set 2
Set 3
Set 4
Set 5
13
Update
Code ID Setting
Code 39 *
Italy Pharmacode *
French Pharmacode *
Industrial 25 *
Interleave 25 *
Matrix 25 *
Codabar *
UPCA *
UPCE *
EAN8 *
EAN13 *
Code 93 *
Code 128 *
MSI *
Plessey *
Telepen * Programming Instructions : (1) Read the label. (2) Program the desi red character
string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
14
Enter Setup
Length Code Setting (2 digits)
Code 39 Length Code
Enable
< Disable >
Italy Pharmacode Length Code
Enable
< Disable >
French Pharmacode Length Code
Enable
< Disable >
Industrial 25 Length Code
Enable
< Disable >
Interleave 25 Length Code
Enable
< Disable >