POS POWER FTPC15V12 Datasheet

ELECTRICAL SPECIFICATION
MODEL
FTPC15V12
OUTPUT
RATED VOLTAGE
12V
1.25A
POWER RANGE
1 ÷ 15W
RATED POWER
15W
LINE REGULATION
± 2%
LOAD REGULATION
± 2%
VOLTAGE TOLERANCE [3]
± 5%
RIPPLE & NOISE (max.) [2]
600mV
P-P
SETUP TIME [4]
2000ms
INPUT
VOLTAGE RANGE
180 ÷ 264VAC
FREQUENCY RANGE
47 ÷ 63Hz
EFFICIENCY (typ.)
75%
AC CURRENT (typ.)
0.25A/230VAC
INRUSH CURRENT (typ.)
50A / 230VAC(25°C)
NO LOAD POWER CONSUMPTION (typ.)
< 0.5W
PROTECTIONS
OVERLOAD
Range: 110 ÷ 130% rated output power
Type: hiccup mode, auto-recovery.
SHORT CIRCUIT
Type: hiccup mode, auto-recovery.
OVER TEMPERATURE
Range: 110°C ± 10°C
Type: shut down output voltage, auto recovery.
FTP15V12
s e r i e s
15W Constant Voltage Single Output LED Power Supply
F T P C 1 5 V 1 2 -s pe c- EN 05 . 0 8 . 2 0 1 4
Features:
• Protections: Short circuit / Over load / Over temperature
• Cooling by free air convection
• Isolation class II
• Compliance to worldwide safety regulations for lighting
ENVIRONMENT
WORKING TEMPERATURE
-20°C ÷ 45°C, tc = 85°C
WORKING HUMIDITY
45 ÷ 85% RH non-condensing
STORAGE TEMPERATURE AND HUMIDITY
-30°C ÷ 70°C, 10 ÷ 98% RH non-condensing
VIBRATION
10 ÷ 500Hz, 2G, 12min / cycle, period for 30min. each along X, Y, Z axes
IP PROTECTION
IP20
SAFETY & EMC REGULATIONS
SFAETY STANDARDS
Compliance to EN61347-1, EN61347-2-13
WITHSTAND VOLTAGE
I-P/O-P: 3.75kVAC/1min
ISOLATION RESISTANCE
I-P/O-P: 2MΩ/500VDC/25°C/70%
EMC EMISSION
Compliance to EN55015
EMC IMMUNITY
Compliande to EN61547;
EN61000-4-2, -3, -4, -5, -6, -8, -11
HARMONIC CURRENT
Compliance to EN61000-3-3; EN61000-3-2
OTHERS
DIMENSIONS
123 x 44 x 19.2mm
WEIGHT AND PACKING
0.069kg; 200pcs./box; box weight and dimensions: 16.7kg, 47 x 25.5 x 29cm
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF i 47μF parallel capacitor.
3. Tolerance incudes set up tolerance, line regulation and load regulation.
4. Setup is measured from 0 to 90% rated output voltage.
5. Power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment must be re-qualify to comply with EMC Directives.
MECHANICAL SPECIFICATION
Terminal Assignment
INPUT
1 AC/N: AC neutral
2 AC/L: AC line
OUTPUT
3 V-: DC OUTPUT -
4 V+: DC OUTPUT +
FTP15V12
s e r i e s
15W Constant Voltage Single Output LED Power Supply
F T P C 1 5 V 1 2- sp ec - E N 0 5 . 0 8 . 2 0 1 4
INPUT
1
2
3
4
OUTPUT
Loading...