SETUP MANUAL
PROGRAMING
SCANNER
BAR CODE
MANUAL VER: MAR20020808
EZ One Shot
DefaultDefault
DEFAULT
Please shut down the Power of your P/C system before connecting the scanner. This process is critical prior protecting both scanner and your P/C system from serious damage
.
WARNING
We reserve the right to change the specifications and other info without prior notice, please contact us for the updated info.
We shall be not liable for the technical or editorial errors or emissions contained herein, nor for consequential or incidental damages resulting from performance abuse of this booklet.
This product is warranted for one year warranty from the date of purchase under proper using conditions, covering defects in material and workmanship. The warranty does not cover incidental or consequential damages incurred by customer misuse, or modification.
and Compliance : This device has been tested and found comply with the limits for a Class B digital pursuant to part 15 of the FCC Rules.
This device has been tested and found compliant with the following listed standards as required by the EMC Directive 89/336/EEC as amended by directives 92/EEC and 93/68/EEC: EN55022(1992); EN55024(1992); EN55082-1 (1998)
All rights are reserved, No part of this document may be photocopied, reproduced, or translated into other language without prior noticed from the owner.
CONTENTS
TABLE OF CONTENTS ----------------------------------------------------------------------- 1
CLONING MODE ----------------------------------------------------------------------------4~5 GETTING STARTED >>> HOW TO FIX THE SCANNER TO THE TERMINAL -----------------------6~7 >>> HOW TO CHANGE A CABLE -------------------------------------------------------- 7 >>> HOW TO SETUP THE PARAMETER.---------------------------------------------- 8
GROUP 1 >>>> INTERFACES SELECTION, COMPUTER TYPE, DEFAULT. ---------- 9 GROUP 2 >>>> READING MODE SETTING. -------------------------------------------- -------10 GROUP 3 >>>> CHECK VERSION, BEEP TONE, CAPLOCK MODE.-------------------- 11 GROUP 4 >>>> PREAMBLE AND POSTAMBLE.-----------------------------------------------12 GROUP 5 >>>> ACCURACY ADJUSTMENT.----------------------------------------------------13
INTRODUCTION, EZ TROUBLESHOOTING ----------------------- --- ----------- 2~3
GROUP 6 >>>> ENABLE AND DISABLE CODE ID.------------------------------------------- 14 GROUP 7 >>>> SYMBOLOGIES CODE ID IDENTIFIER., SET ID --------------- -------- 15 GROUP 8~9 >> CODE ID CONFIGURATION: SET CODE ID ----------------------- 16~17 GROUP 10 >>> DELAY BETWEEN BLOCK AND CHARACTER.-------------------------- 18 GROUP 11 >>> TERMINATOR AND KEYBOARD LAYOUT. -------------------------------- 19 GROUP 12 >>> RS232-BAUD RATE, DATA BITS & PARITY, STOP BITS.--------------- 20 GROUP 13 >>> HANDSHAKING, ------------------------------------------------------------------ 21 GROUP 14 >>> WAND EMULATION PARAMETER SETTING. --------------------------- 21 .
SYMBOLOGIES FORMATING (GROUP 15~ GROUP 31).
GROUP 15 >>> ENABLE AND DISABLE SYMBOLOGIES. -------------------------------- 22 GROUP 16 >>> ENABLE AND DISABLE SYMBOLOGIES. -------------------------------- 23 GROUP 17 >>> CHINA POST CODE ( TOSHIBA CODE), CODE 32.----------------- 24 APPEND 1 >>> NUMERIC TABLE, MIN/MAX LENGTHS SETTING -------------------- 25 GROUP 18 >>> UK PLESSEY CODE, MSI CODE. ----------------------------------------- 26 APPEND 1 >>> NUMERIC TABLE, MIN/MAX LENGTHS SETTING ------------------ 27 GROUP 19 >>> CODE IATA, CODE93.TELEPEN.-------------------------------------------- 28 APPEND 1 >>> NUMERIC TABLE, MIN/MAX LENGTHS SETTING -------------------- 29 GROUP 20 >>> INTERLEAVED 2 OF 5, CODE 11 .----------------------------------------- 30 APPEND 1 > >> NUMERIC TABLE, MIN/MAX LENGTHS SETTING ------------------- 31 GROUP 21 >>> CODABAR.------------------------------------------------------------------------- 32 APPEND 1 >>> NUMERIC TABLE, MIN/MAX LENGTHS SETTING---------------------- 33 GROUP 22 >>> ABC-CODABAR, CX CODE ----------------.--------------------------------- 34 GROUP 23 >>> CODABAR COUPLING, ------------------------------------------------------- 35 GROUP 24 >>> CODE 128, STANDARD CODE 39, FULL ASCII CODE 39.----------- 36 APPEND 1 >>> NUMERIC TABLE, MIN/MAX LENGTHS SETTING -------------------- 37 GROUP 25 >>> INDUSTRIAL 2 OF 5, MATRIX 2 OF 5.------------------------------------- 38 APPEND 1 >>> NUMERIC TABLE, MIN/MAX LENGTHS SETTING--------------------- 39 GROUP 26 >>> UPC-E. ----------------------------------------------------------------------------- 40 GROUP 27 >>> UPC-E(0), (1) ,UPC-E & UPC-A EXPAND ----------------------------- 41 GROUP 28 >>> UPC-A..----------------------------------------------------------------------------- 42 GROUP 29 >>> EAN 8. ------------------------------------------------------------------------------ 43 GROUP 30 >>> EAN 13 ----------------------------------------------------------------------------- 44 GROUP 31 >>> EAN/ UCC 128 -------------------------------------------------------------------- 45
GROUP 32 ~ 39 >>>> FULL ASCII TABLE ( CODE 39 --------------------- 46 ~53 GROUP 40 >>>>> NUMERIC ( CODE 39 ) TABLE. --------------------------- 54 GROUP 41~ 42 >>>> FUNCTION CODE ( CODE 39 ) FOR PC AT.----- 55~56 GROUP 43~ 46 >>>> TROUBLE SHOOTING --------------------------------- 57~60 Ms6262 CONTROL CODE LIST FOR Rs232. -------------------------------------------61
GENERAL
SETTING GROUP
1
GENERAL
INTRODUCTION
Machine-readable bar codes save human from senseless boredom and costly errors of data entry. Human use a keyboard or a mouse for data entry to a computer. Bar codes must be scanned in via some other means. Thus bar code Scanner is a high performance input devices which provide fast and accuracy for bar code encoding, and will improve your work efficiency. The bar Code scanner can be widely applied to Logistic, Hospital, Production, Libraries ,Office Management, Document Management, office Automation, Time & Attendance, Security, Retail and POS, and etc .
Bar Code Scanner looks very simple and easy to install. It seems that you can easily to fix it to your terminal/ computer easily as well as computer mouse and keyboard. In fact, it is a very complicate computer device, there are many technical difficulties in the software setting which need professional assistance.
If you are the FIRST TOUCH bar code scanner users who do not familiarly with a bar code, you are advised that do not set any parameter to the scanner, before you get an expert advisory with the System Integrator Services Provider, , Hardware or software engineers before you go further for setting.
VAR( value-added,
reseller, distributors
EZ TROUBLESHOOTING
To save your time, Before returning the scanner back, you can fix-up the trouble step by step with Easy Troubleshooting guides as follow.
if the troubles are caused by the wrong setting, It can be fixed up easily with the Easy Troubleshooting guide as follow,
Scanners may have a trouble, normally the trouble
attribute to a wrong setting,
1. Step: Unplug the Cable from Terminal.
2. Step: re plugs in the cable from the terminal.
3. Step: Set the scanner to Default ( Group 1)
4. Step: If you did the above steps for troubleshooting, but the troubles are still unsolved, Please finds the troubleshooting which provided at the Figure 2 at the next page.
5. Step: If you tested all the steps as Figure 2, and the scanner is still in problems, please find troubleshooting at Group 43~46 for further assistance.
. A001$
2
Ki
d
f Tr
oub
l
e
s
n
o
Co
m
u
te
r
T
y
e
p p
(
o
up
1)
G
r
n e ce S
l
e
t s
I
t
r
f
a
s
e c i
o
n
G
p
1)
(
r
o
u
S
tti
n
oe
ue
e
g P
rcd
r
h o
t c m
l
te
dav
e
n o
p e
(
e n
ee
Tr
p
e
S t
ti g
N d i l
ht c
a
ni ) S
o
s n
ng
--
-
- -
--
--
--
-
-
- - -
- --
- --
- -
p -
,5
,8
,
1
7 G
r
ou
4
,
9
,
8
1
,
2
0 2
3
,2 , 1
,
9 ,
2 ,
2 4
2
5 1,
3
Li
m
i
t
at
ion
o
e
th off
l n
g
th bar
cod
ee
S
mp
s
y
t
om
Sc
a
n
ne
r p
f
m
e l
as
u
s
, b h
er
s
n
o
y t
p
u
d
ata o
n
er o
r s w l
ual
u
t
t
e
i an
o
u t
of
t o
nit
o
h l s
n
i
he
m
r w
i e
can n
g.
Sc
a
nne
r
w
il
b
ee
p
a
s
und
hen
t
he L
ED
li
gh
t t
urn
of
,
no
won
d
er
how
l
o
t
f
man
y
t
i
mes
ha
t
y
pu
h
t
h
e
swi
t
ch b
ut
t
on
, t
h
e c
a
n
ne
r
st
i l
c
no
t
t o
u s
s
l
a
n
wo
r
k
rop
er
l
y
se
em
s
t
ha
t
t
ha
s
se
i
sly
da
m
a
ge
s
p
, i r ou
.
l
t i
y
e ot
e
t i u
t
he
m
Most y
,
a
l
l s
e
t ng
ne
e
d o
nl
o
n s
h
s
t n
g
, b f
e
w
of t n
ee
d
r pl
i r
s g.
e
st l ow
:T
i
e
scan
n
n
g f
o
et
t
in
T
h
ere
ar
li
ed a
s
f
o l
1
. e
a
m e b
lPr
b
l
, P
ostam
e
(
Gr
o
u
p
4)
.
A
d
j
m G
ou
p
.2
.
Ac
cu
r
a
cy u
s
t e
nt
(
r
5
,
C
u
s
t e
I
o
nf g
u
r
i r
3
. o
m r
D
C
i
a
t
on
(
G o
u
p
8,
9
)
.
i
ax
e
ngt
r
1 21
, 2
5
)
4.
M
n
/
M L
h
(
G
o
u
p
1
7, 8
,
19,
2
0,
22
,
2
4,
.
5.
a a b
et
A
B 23
)S
et A
D t
we
en
C
Coda
bar
( G
rou
p
2
2,
.
6
. be X
- C
o
d
ab
a
r
)
.
S
e
t
A
Data t
we
e
n
C r
(
G o
u
p
22
,
2
3
S t A
i Co
d
a
ba r 3
)7. e
Da
ta
bet
wee
n
Co
u
p
l
ng
r
(
G
ou
p
2
2,
2 .
Def n
e
r
8
. i
EAN12
8
(
G
ou
p
3
1) .
1. a
n
r s
o
a le
t
o re
ad
t
h
e
a
d
er
tain
l
e
g
h bar
ode.
Sc
n e
i
n t b
b r co e in
c n t c
.
i
agnos
e i
t
t y g
w
i
t
a
no
th
r
b
r c
o e
w i
ch shoul
d e
sam
s
mb
o ogi
es
2
D
r in h
e a
d
s
h
b
e
y
l
but i
n di
er
ent
lengt
h
f
f
.
3.
t
e
c
a
nne
r
h
s el
l
e d
to
th
s
i
f
f
r
n
l
e
g
h.
T
e
p o
l
eIf h s
a w r
a
o e
in d e
e t n t h
r
b m
ma
b
cu
e b
t
e n
t
o
M
I
n/
M
axL
n
t
h y e asd
yh
l
egh
f
e
g .
a
cd
b
r oe
s
23
o
R
2 P
r toc
o
l
C
o
m
u
nic
at
io
n
s
e
t
ting
rp
o
b
l
em
R
s
23
2
t
r
o
s l y
e n
ot
m
r
otoc
ol
co
mmu
c
a
t
o
n
o
u
bl
e
m
t
y c
a
used
b th
a
t
ch
of
p ni
i
e
c
an
n
e or m
a
l,
ha
ve
a
b f
or
scann
i
ng,
b
out
pu
ts
t
ti
n
g
.
S r
s
w k n
or eep
ut n
o
f
da
tao
o N
1
2
3
4
So ution
l s
1
. Unpl
ug
c e f
r
om
t
he
er
m
i
,
a
ab
l
T na
l
2
. R
e
pl
ug in t
c e.
h
e ab
l
3.
t
he
sca
t
o
ex
ac
p
u e
r
t pe
mm iat
e
l .
S
et
nn
er
t
C
o
m t
y i
ed
y
1.
Unp
l
c
e
f
r
om
t
e
r
mi ,
u
g
a a
b
l h
T
e n
a
l
2
. Repl
ug
n t
c
e
.
i
h
e a
b
l
3
.
h
e sca
o t
r g nt
e
r
f
ac
e
s
,
o
u
e Se
t
t
n
ner
t h
e
i
h
t
i
y
ar
re
mi
o h
e
ck i
t
h ca
b e s
e t
t
h
e nt
f
e
s
n
d t c
f
e
l
am o
I
e
r a
c
whi
h
ct
y
you w
a
nt
c ex
a
l
.
1
. Th
s
t
t
i
n
g
pr
oc
e
d
u es
a
r
e
be
e
n
de
s
c
i ed
c
l
r
ly
e
e r
r
b
ea
at
e
la
t
p
ag
s
.r
ed
e
or
ex
am
p
le
Cod
= d
e3
9
, Min
en
gt
=
6.
F e C
o L h
an
i
n L
e
ng
t
h (
G
r
o
p
2
) S
c M
u 4
Sc
n
0
"
,
"6"
f
om
Ap
p
en
dix
1
.
a
" r
S
c
M
i
n
e
ng
t an L h
(
G
r
o
u
p 2
4 )
2
.
a
n
ne
r
Be
e
"
Ti
",
"Ti
',
T
"
.
r
u
nco p
le
t
e
d e
t
t
i
g
.
Sc
p
I Fo
m
s
n
3.
S
c
n
ES
ET
t
o
e
t
u
on
ag
i
n
.a
R
s p
e
a
R
e
e t
h
Min
M
a
L
n
g
t
h o
f
th se
sy b
o
lo ie ,
s t
e / x e
o
m
g s
F g
ure
2
i
Set
c
om
m
u
n
icati
on
Pa
ram
et
er o
f
R
2
3
Pro o
c
l
s 2 t
o
:
Bau
d
R
a
te
,
Ha
ns
ha
k
i
n
g, S
t
op
Bi s
, D
a a
B
i
ts
an
P
a
r t
y t
t d
i
atch
be
t
w
e
e
n th
e s
c
a
n
ne
a
n
d
PC
.
m
r
5
3
CLONING MODE
WHAT IS CLONING MODE?
CLONING means duplicate a parameter's setup of a scanner to the other's scanners. It can save much time for lots scanner setting.
HOW SHOULD THE CLONING WORK?
Step 1 : Take a scanner, set all the parameters with this manual. Step 2 : Scan the CLONING MODE bar code shown at Figure 1. Step 3 : nce CLONING MODE is Scanned, all setup parameter will be converted into alphanumeric and throw it to the monitor. Step 4: Use your bar code printer, print out all the value ( data values are Into CODE 39 label. Step 5 : Scan the printed label form up to down sequentially with the scanner which is need to program.. .
O
shown on the monitor.)
. A016$
CLONING MODE
1. All strings are in upper cases.
2. All Cloning string which printed into labels should same to what are shown on the monitor sequentially from 1st row to the end.
3. The CLONING MODE can be work in the Word, Note Pad Only.
4. The bar code of cloning label is Code 39 (No CDV).
5. Never edit data at first row (.A017$). It is an enter gate for cloning.
6. You can adjust the cloning string's length by combined multiple strings into one or breaking one string to multiple strings starting
from Second Row after "....". , Note: the length must be in the
sequences of 4 ( FOUR); Such as 4,8,12,16,20(MAX).
7. Be aware of do not omit to print the dot which should same exactly as what are shown on the monitor.
.
REMARK:
. A018$
CLONING MODE ON- PC/AT
.A018$( Cloning Mode on PC/AT) - you can clone the settings to a PC/AT regardless what kind of device has been chosen on the scanner
Figure 1
* Format of Cloning : 1st rows >>> ".A017$" ( never edit any data of the first row )
2nd rows >>> "....XXXX" you can adjust the String's Length starting
from the dots"...." forward. The length of the string should
be in 4, 8,12,16 or 20 ( MAX )digits. 3rd rows~ so on >>> XXXX End rows- A dot "." Is an ending of cloning.
XXXX Stand for any String
FORMAT OF CLONINGFORMAT OF CLONING
4
Wrong Setting: The string's lengths of second and third rows do not match the length's requirement, because the length should be in the sequences of 4 digits
EXAMPLE :
1. Project Assignments :
1.1. Beep tone: BEEP LOW -- HIGH .
1.2. Capslock Mode: CAPSLOCK ON ( FIXED ).
1.3. Reading Mode: CONTINUOUS AUTO OFF.
2. Setting Procedure:
2.1. Scan BEEP LOW.--HIGH (GROUP 3).
2.2. Scan Scan
3.Scan CLONING MODE.(FIGURE 1). All parameter's will be converted
into alphanumeric, and throw to the monitor.
CAPSLOCK ON (FIXED).(GROUP 3).
2.3. CONTINUOUS AUTO OFF. (GROUP2).
4. Print the result of the monitor into bar codes with your printer. The Bar code should be printed into CODE39 format. The cloning string printed which into bar code will be the EZ cloning Manual.
.A017$
....0604
5A025F04 .
5. scan these labels with any one of the scanners that you would like to programme with same setting function as well as cloning, scan it from first row to second and so on one by one, you should scan it from up to down in sequences.
. A017$
. . . . 0604
5A025F04.
.A017$
....06045
A025F04
.
.A017$....
0604 5A02 5F04.
9 x 7 x . (Dot)
4 4 4+.(Dot)
The 0.A17$ is a FIXED parameter for setup entering. It is an unchangeable parameter. Never adds, delete or
rearrange data from the FIRST row.
X
Wrong Setting Because you add
" ...." After .A017$
RIGHT OF SETTING
WRONG OF SETTING
.A017$
....
0604 5A02 5F04 .
4 4 4 4 . (Dot)
.A017$
....06045A02
5F04.
8+.( Dot)
12
}}
.A017$
..0604 5A02 5F04 .
..
Wrong Setting: The "...." Consists
of 4 Dots, located at the beginning of
second rows, Do not break the "...." Into
multiple string.
string
5
KEYBOARD WEDGE
GETTING STARTED
HOW TO FIX THE SCANNER TO TERMINAL
1. Turn off power to the terminal / computer.
2.. Connect the appropriate RS232 cable to the scanner and Computer. 3 Connect an appropriate power adaptor to the power cord of the cable. 4 Turn on the terminal / computer, . 5 . Plug in the Power Adaptor's to scanner's Power Jack.
6. Scanner will beep a sound for the connection.
7. Set the scanner to RS232 interface with Group 1 (Interfaces Selection). .
8. Set Rs232 Protocol: Baud Rate, Stop Bits, Handshaking, Data Bits& parity.
9. Scan any bar code, check if any data show on monitor?
10.END
REMARK:
1.Before plugging the power adaptor to the scanner, Please check if
the Voltage, Power Consumption, Inner and outer DC Jack's Position of the Power Adaptor is right, otherwise, your carelessness will result in the serious damage for scanner / terminal / Computer
2.Please make sure the PROTOCOLcommunication setting of the scanner like Baud Rate, Data Bits, Parity, Hanshaking MUST match to terminal / Computer RS232 setting, otherwise, no any data will be transmitted..
Rs232 INTERFACES
1. Turn off the power of a terminal / computer / notebook..
2. Disconnected the cable from the terminal / computer
3. Connect an appropriate keyboard cable to the scanner and to the terminal.
4. Turn on the terminal / computer,
5. The scanner will beep a tone after connection. 6 Set the scanner to KEYBOARD interface by referring to GROUP 1 (Interfaces Selections).
7. Scanner beep a tone for complete setting.
8. Scan any bar codes to ensure, see if any data show on the monitor.
9. END.
TO PC COM PORT
Check the power adaptor If:
1.Input of AC current 110V/ 220V match to the power supply standard of your country.
2.Output of Power is 5V DC
3.The jack is inner +5V.
DC JACK
To Power Adaptor
TO PC KB PORT
TO KB
6
The USB Interfaces supported is compatible to Apple MAC series / later PCs and Window 98, Window 2000, Window Me, Window XP.
1. Turn off power to the terminal / computer
2. Disconnected the cable the terminal/ computer.
3. Connect an USB cable to the scanner and to the terminal/ Computer,
4. The scanner will beep a tone for the connection,
5. The Computer will detect the USB Driver automatically.
6. If you are the first USB user, please Installed USB driver step by step carefully by the Instructions of the systems ( 1st Installer)
7. Set Interfaces Selection to Keyboard/USB.
8. Scanner will beep a Tone after Interfaces selections.,
9. Scan any bar codes, check if any data are output to monitor.
10. END.
All scanners are designed at the convenience for Easy Interfaces Conversion, Most scanners' support for
change an interface of scanners from one to another, all you have to do is simply change a cable. Please follow the instruction as follow:
1.Insert a pin to the hole, 2.releases the cable simultaneously,
3.Plug in the new cable which required.
After changes to a new cable, you MUST reset the Interface Selections.
For the symptom, please refer to the trouble of EZ Troubleshooting.)
TTL, Wand Emulation, Keyboard, RS232, Macs ADD, USB interfaces. If you would like to
HOW TO CHANGE A CABLE
USB Interface
New Cable
Present cable
New Cable
Present cable
7
How do you program a scanner with this manual?
EZ One Shot Setting Procedure.
R
HOW TO SETUP THE PARAMETER
.
2. Most programming procedures need only One Shot Setting excepts : Preamble, Postamble, Min / Max Lenght, Accuracy Adjustment.
Set A Data ( Insert data between Two Codabar : CX-Codabar, ABC Codabar, Codabar Coupling) , Define EAN128. ( See related pages for detail instructions). The are shown as follow:
.
1. Aim the scanner directly to the bar code ( function/ parameter ) you want to set,
1.1. Then you will hear TWO beep sounds, mean the NEW parameter is defined or updated into the memory processor.
1.2. Thus, the whole set up procedure is over.
2.1.Preamble / Postamble
Scan CLR PRE/POSTAMBLE Scan PREAMBLE/ POSTAMBLE >>>> Scan any alphanumeric from Full ASCII Table from Group 32 ~Group40. >>>> Scan
2.2.Min Length / Max Length:
Scan
2.3.Accuracy Adjustment:
Scan ACCURACY ADJUSTMENT >>>> Scan One digit number from Numeric Table from APPENDIX 1 >>>>
( Max 16 digits ).
PREAMBLE or POSTAMBLE.
MIN LENGTH or MAX LENGTH >>>> Scan TWO digits number
from Appendix 1. ( next pages to the related setting pages ) >>>> Scan MIN LENGTH or MAX LENGTH.
Scan ACCURACY
ADJUSTMENT.
2.4.Customer configuration ID -- ( Example: Code 39 )
Scan Code39 Set ID from Group8 ~ Group9 >>>> Scan alphanumeric ( Max TWO digits ) of FULL ASCII ( Code 39 ) Table from Group32 ~ Group40. >>>> Scan Code39 Set ID from Group8.
2.5.Set A Data - ( CX-Codabar, ABC Codabar, Codabar Coupling).
Scan Set A Data. >>>> Scan any alphanumeric data ( Max ONE digit ) from FULL ASCII (Code 39) Table from Group32 ~ Group 40 >>>>> Scan Set A Data.
2.6 REMARK:
2.6.1. Most setting procedures of above-mentioned need TRIPLE setting.
2.6.2. Scanners will beep thrree rapid beeps"Ti", "Ti",Ti" to remind incomplete of Setting, please go on to complete the setting.
2.6.3. If you make a mistake, forget where the steps to exit, Scan Reset (. P023$) at below for resetting.
3. SYMBOL AND ABBREVIATION:
3.1. DEFAULT Setting: All Default's Parameters are indicated in bold type and underlined Characters. The Font of the Characters is ARIAL BLACK.
3.2. CD = Check Digits.
3.3. CDV = Check Digits Verification.
. A001$
DEFAULT
. P 0 23 $
RESET
Setting code
8
. A001$
COMPUTER TYPE
. C007$
NOTEBOOK*
. C005$
PC-XT
. C006$
MAC ADB
. C004$
PC- AT
-- GROUP 1 --
.
INTERFACES SELECTION,
COMPUTER TYPE, DEFAULT.
. C001$
KEYBOARD& USB
. C003$
WAND
. C008$
RS485
. C002$
RS232
INTERFACES SELECTION
DEFAULT
Scanners perform well as usual, but there is no any output show on the Computer's monitor while the scanner is reading a bar code.
1.Unplugged the cable from the computer,
2.Replug in the cable,set the scanner to the exact Type of Computer immediately.
SYMPTOMS
SOLUTION
Cautions: Please set to right Computer Type when you change a terminal
The scanner will sound a beep then the LED light turns off, no wonder how many time you push the switch button, the scanner still cannot work properly, LED light will not light, seems that it has been seriously damaged.
1.Please Unplugged the cable from the computer.
2.Replug in the cable, and set the scanner to the right interfaces with the manual immediately.
SOLUTIONSYMPTOMS
*Most scanners are designed with the flexibility for easy Interfaces changing. You can change an interface of a scanner from one to another just simply change a cable. Please do not forget to set the scanner to the interfaces that matched to the cable..
* If Notebook is On, scanner operate with No external keyboard
9
. F001$
FLASH MODE
* LED is always on if bar codes close to the scanner, and turns to flashing when there is no any bar code approaching after 60 sec. * Trigger is in function.
. F005$
CONTINUOUS MODE
* LED is always on. , * The trigger is functionless eternally if Continuous Mode on.
* LED will be switched off automatically when there is no bar Code approaching approximately after 60 Sec. .
* LED is always on when switch is pressed . ( Switch is no function when LED on ) .
. F006$
CONTINUOUS AUTO OFF
. F004$
* Factory Test Scanning
TEST MODE
. F003$
TOGGLE MODE
* This function works as well as trigger Mode, but "GOOD READ" beeps after encoding.
. F002$
TRIGGER MODE
* The LED will be switched on if
triggered. * The LED will be switched off when the switch button is released.
switch
button.is
-- GROUP 2 --
READING MODE SETTING
. F007$
* If Auto- Sensing ( Triggerless.) is on, LED will be turned off if the scanner does not detect for a bar codes.. * LED is lighted up automatically while a bar code is detected.
*AUTO SENSING MODE
. F008$
*ULTRAVIOLET MODE
* If an Ultraviolet Mode is on, Ultraviolet light will be lighted up ( Continuously.). * The Ultraviolet will be turned off if ONE push of a trigger, and back to the mode that you left last.
REMARK:
2 Be informed that only few models support for Auto-Sensing Mode or Ultraviolet Mode.
3.Please prints out the Ultraviolet Mode (.F004$) with A Bar code printers, put the Ultraviolet Setting code near the working station, Scan Ultra violet if you need it,
4.Ultraviolet Mode Converse - Press the trigger button, The reading mode will swift from Ultraviolet Mode to the Reading Mode that you left last.
* Autosensing Mode and Ultraviolet Mode are available only for certain Model.
.
1.For extends the scanner's life time, Please set the scanner into Trigger or Continuous Auto Of Mode.
10
BEEP TONE MODE
. F017$
BEEP LOW
. F015$
BEEP LOW--HIGH
. F013$
BEEP MEDIUM
. F012$
OFF
. F016$
BEEP HIGH--LOW
. F014$
BEEP HIGH
. A007$
CHECK VERSION
. A005$
CAPLOCK OFF
. A006$
CAPLOCK ON ( FIXED )
CAPLOCK ON
. A004$
REMARK
If CAPLOCK ON ( FIXED ) is on, The scanner will sent the Charactor in Capital only, but CODABAR are exeptional. If ABCD/ABCD, abcd/abcd, ABCD/TN*E, abcd/tn*e are on, they work independently according with their rules..
-- GROUP 3 --
CHECK VERSION, BEEP TONE ,CAPLOCK MODE
CAPITAL LOCK MODE
CHECK VERSION
11
. A012$
PREAMBLE (16 )
. A013$
POSTAMBLE
SETTING PROCEDURE
STEP 1 : Scan : CLEAR PRE/ POSTAMBLE. STEP 2 : Scan : PREAMBLE. STEP 3 : Scan : " # " from FULL ASCII Table. STEP 4 : Scan : PREAMBLE. STEP 5 : Scan : POSTAMBLE. STEP 6 : Scan : " $ " , "$ ", From FULL ASCII Table. STEP 7 : Scan : POSTAMBLE.
EXAMPLE:
PREAMBLE String is " # " POSTAMBLE String is " $$ "
. A011$
CLEAR PRE/ POSTAMBLE
PREAMBLE & POSTAMBLE ( PREFIX AND SUFFIX )
PREAMBLE & POSTAMBLE.
A. PREAMBLE ( PREFIX ).
A1. What is PREMABLE , Preamble means user can add any data*** in front of a bar code. A2. MAX input digit ( 16 digit ) . A3. Default Value : None
B. POSTAMBLE ( SUFFIX ).
B
= Barcode
1. What is POSTAMBLE , Postamble means user can add any data*** after a bar code, B2. MAX input digit ( 16 digit ) . B3. Default Value : None
*** The Data can be any alphanumerics data from Group 32 ~ Group 42. (Full ASCII Table ( Code 39 Table )).
C. FORMAT / STRUCTURE OF PREAMBLE & POSTAMBLE (xxxx + KKK + dddddddd + yyyy)
C.1.xxxx = Preamble ( string/ alphanumerics / Function code). C.2.KKK = Code ID C.3.yyyy = Postamble.( String/ alphanumerics / Function code). C.4.dddddddd
REMARK:
( 16 )( 16 )
-- GROUP 4 --
12
Accuracy Adjustment aims to assure for getting more reliable decoded output. The accurate decoded output can be adjusted by customer as follow. The higher the numbers is set mean more accurate output will be. The higher the number is set, .
. A010$
ACCURACY ADJUSTMENT
SETTING PROCEDURE
STEP 1 : Scan : ACCURACY ADJUSTMENT. STEP 2 : Scan : ONE digit Number ( 1--9 ) f rom bar code above. STEP 3 : Scan : ACCURACY ADJUSTMENT.
-- GROUP 5 --
ACCURACY ADJUSTMENT
01234
5
6
7
8
9
** Scanner beep " Ti"," Ti"," Ti", to remind setting incomplete. ** If you made a mistake, do not remember which step to be complished, Scan RESET for resetting.
. P023$
RESET
13
ENABLE CODE ID
-- GROUP 6 --
ENABLE AND DIABLE CODE ID
. A009$
AIM ID ON
. A014$
. A008$
FACTORY ID ON
SET ID -ON
. A015$
DISABLE CODE ID
4 5 6 3 9 8 7 1 2 3 4 5 3 11421
145287
Preamble 145287
CODE ID AIM ID : ]E0
BARCODE / DATA EAN 13 +5
]E0
EXAMPLE : 1.Preamble 145287,
2.Code ID: enable AIM ID,
3.Bar code symbologies : EAN 13+5
OUTPUT : 145287]E0456398712345312411
14
REMARK:
1.Among those Code ID, only ONE type code ID will be sent.
2.Code ID is located at the position before the bar code data and after the preamble, The Structures of data will be show as follow:
-- GROUP 7 --
SYMBOLOGIES CODE ID IDENTIFIER, SET ID
1.Set ID need TRIPLE scanning for setting: The procedures are Step 1: Scan Bar Code ( Set ID ) Step 2: Scan ( 1 OR 2 ) Digit of Full ASCII Table ( Group 32-40) Step 3: Scan: Bar Code ( Set ID ).
Example :Define the MSI Code ID = A, Code 93 = G9 MSI : Step1: Scan MSI Set ID (Group 9). Step2: "A" from Group 35. Step3: Scan MSI Set ID (Group 9). Code 93: Step1: Scan Code 93 Set ID (Group 9). Step2: "G" from Group 36, Scan "9" from Group 40.. Step3: Scan Code 93 Set ID (Group 9).
2. You can Set ( Code ) ID with alphanumeric data from FULL ASCII ( Code 39 ) Table ( GROUP32 ~ GROUP40.)
4. Length's of Set ID are limited to TWO digits. You can input either ONE digit or TWO digit as code ID, if one digit ID is set, the output Code ID of the bar code will be in one digit only, If TWO digits characters are set, The Code ID will be in TWO digits.
5. Only one type Code ID will be sent , you have to choose which type Code ID you wan the scanner to sendt.
SET ID - SETTING PROCEDURES
SYMBOLOGIES
FactoryIDAIM
ID
Factory ID
AIM
ID
MSI O ]M0 N ]F0 EAN 8 S ]E0 DELTA Code G UPC-E E ]E0 LABEL Code C UPC-A A ]E0 UK PLESSY P ]PO EAN 13 F ]E0 MATRIX 2 OF 5 Y ]X0 Code 93 L ]G0 FULL ASCII Code 39 D ]A0 Code 11 J ]H0 STANDARD Co de 39 M ]A0 TELEPEN U ]B0 IATA 2 of 5 R ]R0 EAN 128 T ]C1 V ]S0
Code 128 K ]C0 H ]X0
Code 32
B ]X0 I ]I0
( Code 39 PARAF)
INDUSTRIAL 2 OF 5 ( Code 2 of 5 )
China Post Code ( Toshiba Code )
INTERLEAVED 2 OF 5
SYMBOLOGIES
CODABAR
SYMBOLOGIES CODE ID IDENTIFIER
15
-- GROUP 8 --
. P001$
. P005$
. P007$
. P003$
. P004$
. P002$
Codabar Set ID
UPC E Set ID
UPC A Set ID
CODE 39 Set ID
EAN 13 Set ID
EAN 8- Set ID
. P022$
Telepen Set ID
. P010$
Code 128 Set ID
. P009$
Code 11 Set ID
. P021$
IATA Set ID
. P013$
Code 93 Set ID
. P016$
EAN128 Set ID
. P011$
Code 32 Set ID
CODE ID CONFIGURATION: SET ID
16
-- GROUP 9 --
.
. P015$
. P014$
. P012$
China Post Code [ TOSHIBA Code ] Set ID
MSI Code Set ID
UK Plessy Set ID
. P019$
Delta Code Set ID ( Reserved )
. P020$
LABEL Code Set ID ( Reserved )
. P017$
Matrix 2 of 5 Set ID
. P008$
Full ASCLL Code39 Set ID
. P006$
Interleaved 2 of 5 Set ID
. P018$
Industrial 2 of 5 Set ID
** All Set Code ID need TRIPLE scanning for setting. ** A beep " Ti", " Ti"," Ti" to remind of incomplete setting. ** If you make a mistake, forget where the steps to exit, Scan Reset (.P023$) at below for resetting.
. P023$
RESET
CODE ID CONFIGURATION: SET ID
17
. B002$
. B003$
. B004$
. B005$
. B006$
10mS
50mS
100mS
200mS
500mS
0mS
. B011$
. B012$
. B013$
. B014$
. B010$
500uS
1mS
4mS
16mS
140uS
INTERCHARACTER DELAY
. B001$
18
DELAY BETWEEN BLOCKS AND CHARACTERS
-- GROUP 10 --
INTERBLOCK DELAY
-- GROUP 11 --
. C011$
. C012$
. C010$
GERMAN
FRENCH
. C013$
SPANISH
. C014$
ITALIAN
. C015$
UNIVERSAL CODE
ENGLISH(USA)
KEYBOARD LAYOUT
. D012$
CR
. D013$
CR+LF
. D014$
TAB
. D01 5$
SPACE
. D010$
NONE
ESC
. D016$
. D011$
LF
REMARK : Default parameters of the Terminator.
1. The Terminator default parameter of Keyboard Interfaces is CR.
2. The Terminator default parameter of USB Interfaces is CR
3. The Terminator default parameter of RS232 Interfaces is CR+LF.
. C016$
SWISS
TERMINATOR AND KEYBOARD LAYOUT
19
. E010$
8 Bits ODD
. E011$
8 bits MARK
-- GROUP 12 --
. E015$
7 Bits MARK
7 Bits ODD
. E014$
. E012$
8 Bits SPACE
. E009$
8 Bits EVEN
. E013$
7 Bits EVEN
BAUD RATE
DATA BITS & PARITY
. E008$
8 Bits None
Rs232: BAUD RATE, STOP BITS, DATA BITS & PARITY
. E006$
. E001$
. E002$
600
. E003$
1200
. E004$
2400
. E005$
4800
9600
. E007$
19200
300
. E022$
38400
. E 021$
7 Bits SPACE
20
. E017$
2 STOP BITS
. E016$
STOP BITS
1 STOP BITS
. D005$
Bar High / Space Low
. D006$
Bar Low / Space High
. D004$
HIGH
. E018$
. E019$
. E020$
HANSHAKING
NONE
CTS/RTS
-- GROUP 13--
Rs232 : HANSHAKING
POLARITY OF IDLE CONDITION
. D007$
PEN TYPE
. D008$
FULL ASCII CODE 39
LEVEL DURATION OF MINI WIDTH
. D002$
600uS
. D003$
LOW
. D00 1$
200us
Xon / X off
-- GROUP 14 -­.
WAND EMULATION PARAMETER SETTING
OUTPUT OF WAND EMULATION
WAVE FORM
21
UK PLESSY CODE
. L010$
CODE 32
. K010$
CHINA POSTAL CODE
. K001$
INTERLEAVED 2 OF 5
. J001$
CODE 128
. J010$
CODABAR
. I 001$
ENABLE
. A002$
ENABLE ALL CODE
DISABLE
CHINA POSTALCODE
. K002$
CODE 128
. J011$
CODABAR
. I 002$
. J002$
INTERLEAVED 2 OF 5
CODE 32
. K011$
UK PLESSY CODE
. L011$
. A003$
DISABLE ALL CODE
-- GROUP 15 --
ENABLE and DISABLE SYMBOLOGIES
INDUSTRIAL 2 OF 5
MATRIX 2 OF 5
. N001$
. M01 0 $
INDUSTRIAL 2 OF 5
MATRIX 2 OF 5
. N002$
. M01 1 $
. L014$
. L015$
TELEPEN
TELEPEN
22
. H01 9 $
. H01 3 $
. H00 1 $
. H00 7 $
ENABLE
UPC-A
UPC-E
EAN -13
EAN -8
CODE 93
. I 010$
CODE 11
. G010$
DISABLE
. H02 0 $
. H01 4 $
. H00 2 $
. H00 8 $
UPC-A
UPC-E
EAN-13
EAN-8
CODE 11
CODE 93
. I 011$
. G011$
. M00 1 $
. M00 2 $
EAN-128
EAN -128
-- GROUP 16 --
ENABLE and DISABLE SYMBOLOGIES
MSI
. L001$
MSI
. L002$
. G009$
CODE 39
. G008$
CODE 39
. N017$
. N018$
IATA
IATA
23
-- GROUP 17 --
CHINA POSTAL CODE [ TOSHIBA CODE ]
. K002$
DISABLE
. K003$
DISABLE CDV
. K001$
ENABLE
. K004$
CDV & SEND CD
. K005$
CDV & NOT SEND CD
. K007$
MAX LENGTH ( 48 )
. K006$
MIN LENGTH ( 11)
. K015$
TAILING NOT SEND
. K014$
TAILING SEND
. K013$
LEADING NOT SEND
. K010$
CODE 32
ENABLE
. K011$
DISABLE
. K012$
LEADING SEND
SYMBOLOGIES FORMATTING:
CHINA POST CODE ( TOSHIBA CODE ), CODE 32
24
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
25
. P023$
RESET
-- GROUP 18 --
. L011$
DISABLE
. L010$
UK PLESSY CODE
ENABLE
. L004$
CDV & SEND CD
. L003$
CDV & NOT SEND CD
. L007$
CHECK DIGIT DOUBLE MOD 10
MSI
. L001$
ENABLE
. L002$
DISABLE
. L012$
CDV & SEND CD
. L013$
CDV & NOT SEND CD
. L008$
CHECK DIGIT DOUBLE 11 PLUS MOD 10
. L009$
CHECK DIGIT SINGLE MOD 10
. L006$
MAX LENGTH ( 48 )
. L005$
MIN LENGTH ( 6 )
SYMBOLOGIES : MSI CODE , UK PLESSY CODE
26
27
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
. P023$
RESET
SYMBOLOGIES FORMATTING:
CODE IATA , CODE 93, TELEPEN.
. N021$
CDV & NOT SEND CDV
. N023$
MAX LENGTH ( 48 )
. N022$
MIN LENGTH ( 6 )
-- GROUP 19 --
. G012$
MIN LENGTH ( 6 )
MAX LENGTH ( 48 )
. G013$
IATA
. N0 18 $
DISABLE
. N020$
CDV & SEND CD
. N017$
ENABLE
. N019$
DISABLE CDV
. G011$
DISABLE
. G010$
ENABLE
CODE 93
. L014$
. L015$
TELEPEN
ENABLE TELEPEN
DISABLE TELEPEN
. L021$
. L020$
TELEPEN ASCII
TELEPEN NUMBER
28
29
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
. P023$
RESET
-- GROUP 20 --
INTERLEAVE 2 OF 5
. J002$
DISABLE
. J005$
CDV & NOT SEND CDV
. J004$
CDV & SEND CD
. J007$
MAX LENGTH ( 48 )
. J001$
ENABLE
. J003$
DISABLE CDV
. J006$
MIN LENGTH ( 6 )
. I 014$
CDV & NOT SEND CD
CODE 11
MIN LENGTH ( 6 )
. I 015$
MAX LENGTH ( 32 )
. I 016$
. I 013$
CDV & SEND CD
ENABLE
DISABLE CDV
. I 012$
DISABLE
. I 011$
. I 010$
First Digit Suppressed
. J 008$
. J 009$
Last Digit Suppressed
SYMBOLOGIES FORMATTING:
INTERLEAVED 2 OF 5 , CODE 11.
. I 042$
CDV & SEND CD ( 1 DIGIT )
. I 043$
CDV & SEND CD ( 2 DIGITS )
30
31
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
. P023$
RESET
-- GROUP 21 --
SYMBOLOGIES FORMATTING: CODABAR
. I 008$
MIN LENGTH ( 6 )
. I 009$
MAX LENGTH ( 48 )
. I 002$
DISABLE
. I 006$
CDV & SEND CD
. I 007$
CDV & NOT SEND CD
. I 001$
CODABAR
ENABLE
. I 005$
DISABLE CDV
. I 004$
Not Sent START / STOP
. I 003$
SEND START /STOP
. I 031$
. I 032$
ST/SP: ABCD/TN*E
ST/SP:abc/tn*e
ST/SP: ABCD/ABCD
ST/SP: abcd/abcd
. I 029$
. I 030$
123456 Not Transmit ST/SP A123456B ST/SP: ABCD/ABCD a123456b ST/SP: abcd/abcd A123456N ST/SP: ABCD/TN*E a123456n ST/SP: abcd/tn*e
. I 027$
. I 028$
CLSI FORMAT OFF
CLSI FORMAT ON
CLSI- Enable library space insertion. If you enable the CLSI format, this option inserts spaces in position 2,7,13of the datastring for use in library systems
Example of ST ( Start ) / SP ( Stop )
START / STOP
CLSI FORMAT
32
33
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
. P023$
RESET
-- GROUP 22 --
SYMBOLOGIES FORMATTING:
ABC-CODABAR, CX- CODABAR
. I 039$
. I 036$
INSERT DATA- OFF
. I 017$
. I 018$
ON
OFF
ABC- CODABAR
REMARK: The CX-Code consists of two bar Codes which are decoded in one read cycle, the code is concatenated when the stop character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not transmitted.
CX CODE- CODABAR
. I 022$
ON
. I 023$
OFF
. I 040$
. I 038$
. I 037$
. I 035$
SET INSERT DATA*
INSERT DATA -ON
INSERT DATA -ON
INSERT DATA- OFF
SET INSERT DATA*
ABC-CODABAR (American Blood Commission.).The ABC Code is an acronym for American Blood Commission. This bar code is a variant of the CODABAR Code developed for the use in the blood bank. This Code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a "D ", these two D's are not transmitted.
REMARK:
*The data can be any alphanumerics of FULL ASCII Table ( GROUP 32- 40 )
*The data can be any alphanumerics of FULL ASCII Table ( GROUP 32- 40 )
34
-- GROUP 23--
SYMBOLOGIES FORMATING:
CODABAR COUPLING, ADJACENT MUST ON .
ON
. I 019$
. I 020$
OFF
REMARK:
1.You can enable both ABC-Codabar and CX-Codabar together except Codabar-Coupling.
2.If ABC-Codabar , CX-Codabar, Codabar-Coupling are on together, the scanner will read only Codabar Coupling, either ABC- Codabar or CX-Codabar will be considered as Coupling-Codabar format.
CODABAR COUPLING
. I 026$
. I 041$
. I 033$
ON
OFF
. I 034$
If CODABAR ADJACENT is set to on, the scanner read-only Couple ( TWO ) CODABAR. Codabar which is in " Singer" will not be able to read.
ADJACENT REQUIRED
. I 021$
INSERT DATA -ON
INSERT DATA- OFF
SET INSERT DATA*
ABC-CODABAR and CX-CODABAR code have certain rules of Stop Character of first bar code and the stop character of Second bar code while conjunction, but CODABAR COUPLING does not have any limitation of that, means that while CODABAR COUPLING is on, You can couple whatever TWO Codabar into one data set of data without any limitation between the Stop character of first bar code and the Start character of Second bar code. Both bar code's Start and stop will be sent.
SETTING PROCEDURE - SET INSERT DATA
Set Insert Data ".
Step 1- Scan " Set Insert Data ". Step 2- Scan any data from Full ASCII ( Code39 ) table. The data can be any characters or alphanumeric from Group 32-40) Step 3- Scan "
*The data can be any alphanumerics of FULL ASCII Table ( GROUP 32- 40 )
.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting OR Scan RESET for resetting.
35
. P0 2 3$
RESET
-- GROUP 24 - -
. J011$
DISABLE
CODE 128
. J010$
ENABLE
. J012$
MIN LENGTH ( 5 )
. J013$
MAX LENGTH ( 48 )
STANDARD CODE 39 & ASCII 39FULL
. G002$
FULL ASCII CODE 39 DISABLE
. G008$
ENABLE
REMARK:
The DEFAULT parameter of Code 39 is Standard Code 39 . If you enable Full ASCII Code 39, the Standard Code 39 is disabled automatically.
. G009$
DISABLE
. G014$
START / STOP - SEND
. G007$
MAX LENGTH ( 48 )
. G004$
CDV & SEND CD
. G005$
CDV & NOT SEND CD
. G006$
MIN LENGTH ( 1 )
. G003$
DISABLE CDV
. G015$
START / STOP Not SEND
. G001$
FULL ASCII CODE 39 ENABLE
SYMBOLOGIES FORMATTING:
STANDARD CODE39,FULL ASCII CODE 39.
CODE 128,
36
37
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
. P023$
RESET
. M01 3 $
CDV & SEND CD
. M01 4 $
CDV & NOT SEND CD
DISABLE CDV
. M01 2 $
DISABLE
. M01 1 $
MATRIX 2 OF 5
ENABLE
. M01 0 $
. M01 6 $
MAX LENGTH ( 48 )
. M01 5 $
MIN LENGTH ( 6 )
INDUSTRIAL 2 OF 5
. N001$
ENABLE
. N003$
DISABLE CDV
. N005$
CDV & NOT SEND CD
. N007$
MAX LENGTH ( 48 )
. N006$
MIN LENGTH ( 6 )
. N002$
DISABLE
. N004$
CDV & SEND CD
-- GROUP 25 - -
SYMBOLOGIES FORMATTING:
INDUSTRIAL 2 OF 5, MATRIX 2 OF 5
38
39
0123456
7
8
FULL ASCII ( Code 39 ) NUMERIC TABLE
9
SETTING PROCEDURE
STEP 1 - Scan: MIN / MAX LENGTH STEP 2 - Scan : " TWO DIGIT " Number from Appendix 1. STEP 3 - Scan: MIN / MAX LENGTH.
APPENDIX 1
1.Min Length & Max Lengths need Triple Setting.
2.If any setting steps are not accomplished as above mentioned setting procedure, the scanner will beep a long beep " Ti", "Ti", "Ti" to remind you. Please go on to complete the setting.
3.Suppose you made a mistake, or lose your place while setting, cans RESET (. P023$) at below for resetting.s
MIN / MAX LENGTH (Default Length)
Be noticed that the scanner will only read a bar code within the length's limit. Any bar codes which the length out of limitation range will not be read. The Default's lengths of symbologies are marked clearly at the column after Min/Max Length.
. P023$
RESET
. H01 0 $
LEAD DIGIT SEND
. H00 9 $
. H00 8 $
. H00 7 $
. H04 7 $
. H04 8 $
. H04 0 $
. H03 9 $
. H03 7 $
UPC-E
. H01 1 $
. H01 2 $
DISABLE
CHECK DIGIT NO SEND
. H05 5 $
. H05 6 $
ADD ON SUPPLEMENT
. H03 8 $
-- GROUP 26 - -
SYMBOLOGIES FORMATTING: UPC-E
ENABLE
LEAD DIGIT SEND
CHECK DIGIT SEND
+5 ON
+ 5 OFF
+2 ON
+ 2 OFF
ADD A SPACE ON
ADD A SPACE OFF
ADDENDA REQUIRED ON
ADDENDA REQUIRED OFF
REMARK: If ADDENDA REQUIRED is set to ON, The
scanner will only read UPC-E bar code which has addenda.
40
. H 0 5 3 $
. H 0 5 4 $
REMARK:
1.If UPC E EXPAND TO UPC A FORMAT set to on, The output of UPC-A
will be 12 digits.
2. The default output of UPC-A is 12 digits, if UPC-A EXPAND TO EAN13 is enabled, the output of UPC-A will be changed to 13digits as EAN 13 format.. A Zero will be added to in front of the bar code,
. H0 6 3 $
. H0 6 5 $
. H0 6 6 $
. H0 6 4 $
UPC EO
UPC-E EXPAND TO UPC-A
UPC E1
-- GROUP 27 - -
SYMBOLOGIES FORMATTING:
UPC-E, UPC-A & EAN 8 EXPAND.
UPC-E SYSTEM
NUMBER,
. H 0 6 7 $
. H 0 6 8 $
. H 0 7 0 $
. H 0 6 9 $
UPC-A EXPAND TO E EAN -13
ENABLE
REMARK:
MOST UPC Barcodes lead with 0 number systems, For these bar codes
use UPC E(0) Selection, If the barcodes lead with 1 number systems, use UPC(E1) selection.
ENABLE
E ( 0 ) ON
E ( 1 ) ON
E ( 1 ) OFF
E ( 0 ) OFF
DISABLE
DISABLE
RESERVED
RESERVED
RESERVED
41
. H03 6 $
. H03 5 $
. H03 4 $
. H03 3 $
ADD ON SUPPLEMENT
. H04 5 $
. H04 6 $
UPC- A
DISABLE
LEAD DIGIT SEND
ENABLE
. H00 3 $
. H00 2 $
. H00 1 $
. H00 4 $
. H00 5 $
. H00 6 $
LEAD DIGIT NO SEND
CHECK DIGIT SEND
CHECK DIGIT NO SEND
. H05 9 $
. H06 0 $
-- GROUP 28 - -
SYMBOLOGIES FORMATTING: UPC -A
ADD A SPACE ON
+5 ON
+ 5 OFF
ADD A SPACE OFF
+2 ON
+ 2 OFF
ADDENDA REQUIRED ON
ADDENDA REQUIRED OFF
REMARK: If ADDENDA REQUIRED is set to ON, The
scanner will only read UPC-A bar code which has addenda.
42
. H03 2 $
. H03 1 $
. H03 0 $
. H02 9 $
ADD ON SUPPLEMENT
. H04 3 $
. H04 4 $
DISABLE
. H02 0 $
LEAD DIGIT SEND
. H02 1 $
. H01 9 $
EAN-8
LEAD DIGIT NO SEND
. H022$
CHECK DIGIT NO SEND
. H02 4 $
CHECK DIGIT SEND
. H0 2 3 $
. H06 1 $
. H06 2 $
-- GROUP 29 - -
SYMBOLOGIES FORMATTING: EAN 8
+ 5 ON
+ 5 OFF
+ 2 ON
+ 2 OFF
ADDENDA REQUIRED ON
ADDENDA REQUIRED OFF
ADD A SPACE ON
ADD A SPACE OFF
ENABLE
REMARK: If ADDENDA REQUIRED is set to ON, The
scanner will only read EAN-8 bar code which has addenda.
43
EAN-13
DISABLE
. H01 4 $
ENABLE
. H01 3 $
LEAD DIGIT SEND
. H01 5 $
ADD ON SUPPLEMENT
. H01 8 $
. H01 6 $
LEAD DIGIT NO SEND
CHECK DIGIT NO SEND
. H01 7 $
CHECK DIGIT SEND
-- GROUP 30 --
SYMBOLOGIES FORMATTING: EAN13
. H02 5 $
+ 5 ON
. H02 6 $
+ 5 OFF
. H02 7 $
+ 2 ON
. H02 8 $
+ 2 OFF
. H04 1 $
. H04 2 $
. H05 7 $
. H05 8 $
ADD A SPACE ON
ADD A SPACE OFF
ADDENDA REQUIRED ON
ADDENDA REQUIRED OFF
REMARK
1.If ADDENDA REQUIRED is set to ON, the scanner will only read EAN-13 bar code which has addenda; the EAN-13 bar codes that without addenda will not be read by Scanner.
2.Either ISBN or ISBN will be considered as an extension of EAN-13, codes, thus if you need ISSN or ISBN to read with Addenda, you must enable EAN13, and Addenda Required ON / OFF..
44
-- GROUP 31 - -
SYMBOLOGIES FORMATTING: EAN/UCC-128
ISSN OFF
. H05 2 $
. H05 1 $
ISSN ON
ISBN ON
. H05 0 $
ISBN OFF
. H04 9 $
ISBN
. M00 5 $
. M00 6 $
. M00 7 $
FUNC 1CHEAR SEND
STEP 1:Scan DEFINE EAN128. >>> STEP 2: Scan ASCII Code from FULL ASCII Table. >>> STEP 3: Scan DEFINE EAN128.
FUNC 1 CHEAR NOT SEND
. M00 3 $
. M00 4 $
. M00 1 $
. M00 2 $
DISABLE
CODE ID ENABLE
CODE ID DISABLE
EAN/ UCC- 128
ENABLE
.
The first FNC1 character is translated to ]c1, and the second FNC1 character is translated to an ASCII <GS> character ( scan from Group 32- 40 ).
REMARK :DEFINE EAN 128
ISSN
DEFINE EAN 128
]C1 DATA CHARACTERS <GS> DATA CHARACTERS
String format :
Setting Procedure:
REMARK:
Both ISSN and ISBN are the extension code of EAN-13, If you want the scanner to read either ISSN or ISBN, you must Enable EAN13, otherwise the scanner will not able to read the ISSN or ISBN.
45
$F$H$J$D$L
$B
STX
EOT
ACK
BS
%U
NUL
LF
FF
SO
$N
$I
$K
$M
BEL
HT
ETX
$G
ENQ
$E
$C
VT
CR
$A
SOH
$O
SI
-- GROUP 32 - -
FULL ASCII TABLE ( CODE 39 )
46
DC1
$Q
$W
ETB
$Y
EM
%A
ESC
DC3
$S
NAK
$U
%C
GS
$T$V$X
DC4
SYN
CAN
$Z
SUB
DLE
$P
$R
DC2
RS
%D
FS
%B
-- GROUP 33 - -
FULL ASCII TABLE ( CODE 39 )
47
!
/ A
US
%E
#
/ C
%
%
SP
/ B
"
$
$
/ F
&
%F
;
%H
=
%J
?
%G
<
/ Z
:
%I
%V
>
@
-- GROUP 34 - -
FULL ASCII TABLE ( CODE 39 )
48
/ G
'
/ J
*
-_ .
.
A
A
C
C
E
E
/ I
)
/ H
(
++/ L
,
/
/
B
B
D
D
F
F
-- GROUP 35 --
FULL ASCII TABLE ( CODE 39 )
49
I
I
K
K
PRN
N
T
T
P
R
L
L
G
G
M
M
H HJ
J
O
Q
S
O
SQU
U
-- GROUP 36 - -
FULL ASCII TABLE ( CODE 39 )
50
X
X
Z
Z
%L
\
%N^%O%W
`
VV+B
b
Y
Y
%K
[
%M
]
%O
-
+A
a
W
W
+C
c
+D
d
-- GROUP 37 - -
FULL ASCII TABLE ( CODE 39 )
51
h
j
f
l
k
i
g
e
m
o
n
+F+G+H
+I+J+K+L+M
+N+O+P
p
+Q
q
+R
r
+S
s
+E
-- GROUP 38 - -
FULL ASCII TABLE ( CODE 39 )
52
}
v
x
z
+V+X+Z%R%T
%V/ F
y
w
u
{
|
+U
+W
+Y%P%Q
%S
~
DEL
ENTER
+T
t
-- GROUP 39 --
FULL ASCII TABLE ( CODE 39 )
53
0
0
2
2
4
4
6
6
8
8
1
1
3
3
5
5
7
7
9
9
-- GROUP 40 --
FULL ASCII ( CODE 39 ) NUMERIC TABLE
54
F10
F8
F6
F4
F12
F7
F9
F5
F3
F11
Home
F1
F2
End
$T B
$T A
$T C
$T D
$T E
$T F
$T G
$T H
$T I
$T J
$T K
$T L
$T M
$T N
-- GROUP 41 - -
FUNCTION CODE ( CODE 39 ) FOR PC AT
55
$T X
$T Z
Ins
Page Down
Back Tab
Down
$T V
$T T
$T R
Left
Enter
$T U
$T W
$T Y
Up
Page Up
Tab
Esc
$T S
$T Q
BS
$T %K
Right
Del
$T O
$T P
-- GROUP 42 --
FUNCTION CODE ( CODE 39 ) FOR PC AT
56
POOR BAR CODE SYMBOL QUALITY.
INCORRECT INTERFACES CONNECTION
INCORRECT CONFIGURATION SETUP
The Decoder CCD scanner is a simple device to install and use. Therefore, most of the problems can be attribute to these areas: The troubleshooting process may follow simple procedures as below:
TROUBLE SHOOTING
In general, Keyboard interface is trouble free, but there are some items to check if you are facing problems.
Most computers use XT/AT compatible keyboard. Therefore, Select the proper cable for your computer.
Do you have the correct cable?
3. If the scanner can" GOOD " read, then proceed to check the interfaces cabling connections.
.
if reading the bar code does not result in a " Good Read", then there was a problem with either the scanning technique or the interfaces configuration setting( Reset it to DEFAULT ).
.
2. Once the power is on, try to scan bar code samples at page: The scanner will " Good Read" Beep and "Good Read" Flash When the scanner is in default configuration.
1. First, make sure your scanner firmly connect with PC/ system and should emit one long beep afterward. When the trigger button is pressed, a flash red light should be visible.
-- GROUP 43 --
GENERAL PROCEDURES
KEYBOARD INTERFACES
PROBLEMS.
57
Since the key- in data from keyboard must pass through the decoder, the cabling connections are correct if the keyboard is functioning well.
Does the keyboard work.
Most notebook computers do not supply enough power to the scanner. The symthom is commonly visible by lower good read rate since there is no enough power to a support the scanning operation.
Does Keyboard port supply enough power ?
Computer's BIOS has a feature related to keyboard typing speed. Try to setup Intercharacter Delay' ( page ) to stimulate the effect of the keystroke speed.
Can your computer accept the data fast enough?
There are no industrial standareds for scanner interfaces cables, even if they look alike and have similar connector. For example: cables for keyboard & Wand Emulation are similar, but they cannot be interchanged each other due to different Pin assignments. Be sure your cable attaches correctly to the matching connector.
The cable seems to connect properly but the scanner
cannot send data to host computer.?
Check the configuration setting of the decoded scanner and make sure your decoder can accept the bar code format.
Are you using Wand Emulation mode with Code-39 output and is your decoder set up accordingly to accept Code-39 data?
INTERFACE PROBLEMS
TROUBLE SHOOTING
-- GROUP 44 --
58
1.Interface setting does not match with the right interface. For instance you select keyboard cable, but you had set it to Rs232 or Wand Emulation.
Are you setup to the Right Interfaces
Every bar code symbologies can be individually enabled and disabled. It is suggested to enable only those that will be used, thereby eliminating any misread by the scanning of other symbologies.
Is the proper symbology enabled?
The scanned data from each bar code symbology can be restricted to eliminate the scanning of undesired symbologies. The restrictions are individually set for each symbology.
Do the select the bar code symbology configuration match the bar code?
Symthom ---- ( The LED stuck ,and
no
lighting is
function at all, even triggered
the scanner )
2. Forget to set to right interface after cable changing.. For instance, you want to change Keyboard to RS232, you forget to set the interfaces to RS232 interface..
Solution ----- Set the Scanner to Default condition, and choose the right interfaces
CONFIGURATION SETUP
TROUBLE SHOOTING
-- GROUP 45 --
59
The third problem area has nothing to do with the unit, but rather the quality of the bar code and / or the scanning technique.
TOLERANCE OF BAR CODE
.
Bar codes may have a tolerance. Normally the tolerances are caused by Bar code software or of printer, a reputation high quality bar code software should be choose to generate bar codes. If the printed bar codes have varied bias distortion of printing, the scanners will not recognise these bar codes. . Users are very difficult to get Good Read" from a poor quality bar code with the unit unless they scan the symbol many times. As the quality of the symbol drops, the chances for the undetected error increase. A bar code (CDV) Check Digit Verification should br used to check the quality of the suspect symbols.
LABELS ( PAPER & COLOR& PRINTER MACHINE )
.
Mostly, The light source of a bar code reader is RED, there are some restrictions for label printing, you should be very careful when choosing bar code printing material especially colour ink and paper. Sometimes, as the combination between colour of a label and colour of the ink, it will cause blindness for the scanner, as optics physical phenomenon, some colours should be avoided as it will cause the blindness for the scanner. Regarding this restriction, please consults with the experts for the detail.
Morever, Bad quality of printing will also results in reading difficulties for the scanner, The bad printing may be caused by type of printer machines that you use. Please choose a professional and high quality bar code printer for label printing. For your advisory, please avoid printing the bar code with Dot Matrix and Inkjet printers which will result in the bad quality of printing.
Besides, the quality and condition of the Ink, Ribbon, Carbon, toners which are not very good condition will also result in the bad quality of bar code labels. Thus, please always check if the Ink, ribbon, Carbon toners of the printers are in good condition.
Finally, You should be very careful of choosing Bar code printing material. The printing material which with the shining surfaces will cause the reading difficulties for scanners, so please avoid using the shining material for bar code printing.
.
POOR BAR CODE QUALITY
TROUBLE SHOOTING
-- GROUP 46 --
60
1.The chart shown above is work for MT6262 Fixed Mount CCD bar code scanner setting only.
2.you can easy to set it through keyboard.
3.Setting procedure: for example MATRIX 2 OF 5 ENABLE , KEYBOARD = P,0 SETTING PROCEDURE: STEP 1: Press P of the keyboard.. STEP 2: Press 0
of the keyboard.
MT6262 CONTROL CODE LIST FOR RS232
NO FUNCTION KEYBOARD ASCII CODE
1
SYSTEM RESET
ESC KEY 1BH
2
SET TO DEFAULT(FLASH MODE)
A,0 KEYS 41H,30H
3
SETUP NONE HANDSHAKING
A,1 KEYS 41H,31H
4
SETUP CTS/RTS HANDSHAKING
B,0 KEYS 42H,30H
5
SETUP Xon/Xoff HANDSHAKING
B,1 KEYS 42H,31H
6
UPCA CODE ENABLE
C,0 KEYS 43H,30H
7
UPCA CODE DISABLE
C,1 KEYS 43H,31H
8
I 2 of 5 CODE ENABLE
D,0 KEYS 44H,30H
9
I 2 of 5 CODE DISABLE
D,1 KEYS 44H,31H
10
FULL ASCII CODE 39 ENABLE
E,0 KEYS 45H,30H
11
FULL ASCII CODE 39 DISABLE
E,1 KEYS 45H,31H
12
CODE 93 ENABLE
F,0 KEYS 46H,30H
13
CODE 93 DISABLE
F,1 KEYS 46H,31H
14
CODABAR ENABLE
G,0 KEYS 47H,30H
15
CODABAR DISABLE
G,1 KEYS 47H,31H
16
CODE 128 ENABLE
H,0 KEYS 48H,30H
17
CODE 128 DISABLE
H,1 KEYS 48H,31H
18
CODE 11 ENABLE
I,0 KEYS 49H,30H
19
CODE 11 DISABLE
I,1 KEYS 49H,31H
20
CODE 32 ENABLE
J,0 KEYS 4AH,30H
21
CODE 32 DISABLE
J,1 KEYS 4AH,31H
22
EAN13 ENABLE
K,0 KEYS 4BH,30H
23
EAN13 DISABLE
K,1 KEYS 4BH,31H
24
UPCE ENABLE
L,0 KEYS 4CH,30H
25
UPCE DISABLE
L,1 KEYS 4CH,31H
26
EAN8 ENABLE
M,0 KEYS 4DH,30H
27
EAN8 DISABLE
M,1 KEYS 4DH,31H
28
CODE 39 ENABLE
N,0 KEYS 4EH,30H
29
CODE 39 DISABLE
N,1 KEYS 4EH, 31H
30
INDUSTRIAL 25 ENABLE
O,0 KEYS 4FH,30H
31
INDUSTRIAL 25 DIABLE
O,1 KEYS 4FH,31H
32
MATRIX 2 OF 5 ENABLE
P,0 KEYS 50H,30H
33
MATRIX 2 OF 5 DISABLE
P,1 KEYS 50H, 31H
SETTING PROCEDURE
61
Loading...