PD-300 SERIES
FCC Notes:
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions manual, may cause
interference to radio communications. It has been tested
and found to comply with limits for a Class A digital
device pursuant to subpart J of Part 15 of FCC Rules,
which are designed to provide reasonable protection
against interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause interference in
which case the user at his own expense will be required to take whatever measures to correct the
interference.
Warranty Limits:
Warranty terminates automatically when any person other than the authorized technicians opens
the machine. The user should consult his/her dealer for the problem happened. Warranty voids if
the user does not follow the instructions in application of this merchandise. The manufacturer is by
no means responsible for any damage or hazard caused by improper application.
About This Manual:
Posiflex has made every effort for the accuracy of the content in this manual. However, Posiflex
will assume no liability for any technical inaccuracies or editorial or other errors or omissions
contained herein, nor for direct, indirect, incidental, consequential or otherwise damages, including
without limitation loss of data or profits, resulting from the furnishing, performance, or use of this
material.
This information is provided “as is” and Posiflex Technology, Inc. expressly disclaims any
warranties, expressed, implied or statutory, including without limitation implied warranties of
merchantability or fitness for particular purpose, good title and against infringement.
The information in this manual contains only essential hardware concerns for general user and is
subject to change without notice. Posiflex Technology, Inc. reserves the right to alter product
designs, layouts or drivers without notification. The system integrator shall provide applicative
notices and arrangement for special options utilizing this product. The user may find the most up
to date information of the hardware from web sites: http://www.posiflex.com or
http://www.posiflex.com.tw
All data should be backed-up prior to the installation of any drive unit or storage peripheral.
Posiflex will not be responsible for any loss of data resulting from the use, disuse or misuse of this
or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced, stored in a
retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying,
or otherwise, without prior express written consent from Posiflex Technology, Inc. the publisher of
this documentation.
© Copyright Posiflex Technology, Inc. 2011
All brand and product names and trademarks are the property of their respective holders.
2 X 20 LCD
CUSTOMER DISPLAY
Rev. D0
Part 1
FEATURES
Two - line LCD display with 20 characters per line.
Dark blue character with yellow green back-light
Easy viewing characters (6.0 mm by 9.66 mm)
Display area 143 mm by 21 mm
Euro dollar sign supported in USA/European font table
Selectable command emulation modes including PST and EPSON
command emulation modes
Long life, trouble free and user friendly operation
Composed of several members in the family for versatile
applications as tabulated below
MODEL NUMBERS
INSTALLATION GUIDE
POWER PREPARATION
FOR PD-300, PD-300U:
For these models of customer display it need to be powered by a separate
power adaptor. Therefore there is no need for any operation in the POS host
system. The power adaptor for PD-300 supplies 12VAC, the power adaptor for
PD-300U can either be the 12V AC one or the + 24V DC power adaptor for
Posiflex POS printer and to support the printer through use of on option
cable.(P/N: 21863250900)
FOR PD-302, PD-305, PD-306, PD-307, PD-308:
For these models of customer displays to be used in Posiflex touch terminal
systems, the internal jumpers of the touch system should be modified to
provide + 5 V DC power to the customer display through the specific
Part 3
Part 2
interface cable to support the operation of the customer display. For PD-302,
please separate the main unit of host system (TP series) from the base and
open the service window on back of main unit as described in User’s Manual
of the system. Have a qualified electronic technician to adjust during power off
the internal jumper in service window to supply 5 V DC to the COM port
selected for the customer display following guide from relevant technical
manual. For PD-305 and PD-306, same operation as for PD-302 is required for
the host system (KS or TP series). For PD-307, a qualified electronic
technician will be required to open the top cover of the base (main) unit of HT
or PB series host system during power off to adjust the internal jumper to
supply 5 V DC to the COM port selected for the customer display following
guide from relevant technical manual. For PD-308, a qualified electronic
technician will be required to open the base unit of FT series host system
during power off to adjust the internal jumper to supply 5 V DC to the COM
port selected for the customer display following guide from relevant technical
manual.
FOR PD-303:
There are 2 cables from the PD-303 for application in a host computer system
as shown in the right picture. The cable with a DB9 female connector is for
connection to the COM port of the system for data transmission. Plug the
male/female connector pair of the other cable in between PS/2 KB and KB port
of the host computer system for power support.
FOR PD-306U, PD-307U, PD-308U:
The power for the USB interface type pole display is supported through the
USB connection. Therefore there is no need for any operation in the FT series
host system. However, should these customer displays are to be connected
through an USB HUB instead of a direct USB port of the system, the HUB
must be powered by a separate power adaptor otherwise there could be the
power shortage problem.
PHYSICAL INSTALLATION
PD-300, PD-300U:
In base of stand alone models, looking from rear side of the bottom, the
connector area will look like below:
For PD-300 model:
The RJ45 type modular connector is for internal use and is already
Part 3