PD - 2601 / 2602 Series
FCC Notes:
This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions manual,
may cause interference to radio communications. It has been tested and found to
comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC
Rules, which are designed to provide reasonable protection against interference when
operated in a commercial environment. Operation of this equipment in a residential area
is likely to cause interference in which case the user at his own expense will be required
to take whatever measures to correct the interference.
Warranty Limits:
Warranty terminates automatically when any person other than the authorized
technicians opens the machine. The user should consult his/her dealer for the problem
happened. Warranty voids if the user does not follow the instructions in application of
this merchandise. The manufacturer is by no means responsible for any damage or
hazard caused by improper application.
About This Manual:
Posiflex has made every effort for the accuracy of the content in this manual. However,
Posiflex will assume no liability for any technical inaccuracies or editorial or other
errors or omissions contained herein, nor for direct, indirect, incidental, consequential
or otherwise damages, including without limitation loss of data or profits, resulting
from the furnishing, performance, or use of this material.
This information is provided “as is” and Posiflex Inc. expressly disclaims any
warranties, expressed, implied or statutory, including without limitation implied
warranties of merchantability or fitness for particular purpose, good title and against
infringement.
The information in this manual contains only essential hardware concerns for general
user and is subject to change without notice. Posiflex reserves the right to alter product
designs, layouts or drivers without notification. The system integrator shall provide
applicative notices and arrangement for special options utilizing this product. The user
may find the most up to date information of the hardware from web sites:
http://www.posiflex.com or http://www.posiflex.com.tw
All data should be backed-up prior to the installation of any drive unit or storage
peripheral. Posiflex will not be responsible for any loss of data resulting from the use,
disuse or misuse of this or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced,
stored in a retrieval system, or transmitted in any form or by any means, electronic,
mechanical, photocopying, or otherwise, without prior express written consent from
Posiflex Inc. the publisher of this documentation.
© Copyright Posiflex Inc. 2006
All brand and product names and trademarks are the property of their respective holders.
User’s Manual
Rev. A0
P/N: 19460901120
Part 1
BRIEF INTRODUCTION
THE PRODUCT
The PD-2601 is a pole mount customer display option designed for
Posiflex HT series POS terminals and also the PB series discrete systems. The
PD-2602 is a pole mount customer display option designed for Posiflex KS or
TP series touch POS terminals. It is delivered in separate carton for HT / PB /
KS / TP series and shall be installed per instruction in this manual.
FEATURES
• Bright VFD (vacuum fluorescent display) with green or blue filter
• Rear mount Pole Display for Posiflex HT series hybrid terminals or
PB series discrete systems or KS series fanless touch POS terminals
or TP series touch POS terminals
• Two-line display with 20 characters per line
• Adequately large characters for easy viewing (9.03 mm by 5.25
mm)
• Long life and trouble free operation
• 15°, 30° and 45° adjustable viewing angles
• Total height 486 (or 386) mm (PD-2601 on HT and PB series)
• Total height 330 mm (PD-2602 on base of KS and TP series)
• Display frame can rotate horizontally 270° freely
• Various command emulation modes selectable by DIP switch
• Support 12 Code Pages of 128 characters each
• Support 12 international character sets of 12 characters each
• Simple installation
• Selectable between Serial (RS232) interface model and USB
interface model
• Supports UPOS 1.8 and is WEPOS ready
• Case color choices: ivory, charcoal for HT and TP terminals or
ivory, black for KS terminals
Part 2
INSTALLATION GUIDES
HOST SYSTEM PREPARAION
For serial interface (RS232) PD-2601or PD-2602 to be used in HT or
PB or KS or TP series, you have to adjust during power off the internal jumper
of the host system to supply 5 V DC to the COM port selected for the serial
interface pole display. This adjustment has to be done by a qualified electronic
technician following guide from relevant technical manual. The default
communication protocol should be set to 9600 bps, none parity, 8 data bits, 1
stop bit with hardware handshaking on CTS. The power for the USB interface
type pole display is supported through the USB connection.
INSTALLING PD-2601
Opening the back cover on system
For ease of PD-2601 installation operation, the HT
main unit or PB system has to be opened with sufficient
precautions. First push in the circled knobs on both sides as
in Pix. 1 to remove the back cover. Take out the arrow
pointed pole cover from it.
Opening the top cover of system
Prepare a piece of clean soft clothe of appropriate
size in front of the HT system to prevent damage. Turn the
display panel to straight up position. For both HT and PB
system, push in the rectangular marked spring button in Pix. 1 on both sides of
chassis and raise the rear edge of the top cover. The COM port DC support can
be set at this moment.
Find joining points on system
A
Refer to Pix. 2 that is a picture of the HT or PB chassis near the right
bottom corner (as you are facing the HT or PB system from its back) with
several portions enlarged around, please find 2 rectangular PD installation
holes A on the bottom chassis; 2 circular locating holes B on I/O plate; and 2
circular screw holes C on metal sidewall.
B B
C
Part 3