This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions manual, may cause interference
to radio communications. It has been tested and found to comply with limits for a Class
A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to
provide reasonable protection against interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference in which case the user at his own expense will be required to take whatever
measures to correct the interference.
Warranty Limits:
Warranty terminates automatically when any person other than the authorized
technicians opens the machine. The user should consult his/her dealer for the problem
happened. Warranty voids if the user does not follow the instructions in application of
this merchandise. The manufacturer is by no means responsible for any damage or
hazard caused by improper application.
Please always read thoroughly all the instructions and documents
delivered with the product before you do anything about it. Don’t
take any premature action before you have a full understanding of
the consequences.
This product contains inside a Lithium battery. Please always
follow local environmental protection laws / regulations for
disposal of used batteries and always replace only with battery of
same type.
If you have an UPS battery installed in the product:
Temperature above 40°C must be strictly avoided as it
could cause termination of battery life and unexpected result
even if the battery is not in work.
Do not power off the system just by shutting off the AC
power leaving the battery supporting the whole system till
completely exhausted. Repeatedly using it up or improper maintenance reduces the battery life dramatically.
Always fully recharge the UPS battery at least once every 3
months if the battery is not connected.
Always disconnect the UPS battery from the system if the
system is to be left OFF for more than 72 hours to prevent
possible damage. Only connect the UPS battery back right
before you are going to re-power on the system.
Replace the UPS battery as soon as the monitoring software
indicates the battery is out of service. Attempt to recharge a
dead battery is dangerous!
A separate battery monitor is not required for this series.
DAILY MAINTENANCE GUIDE
For regular cleaning of the XT system, please use only soft haired brush or dry
soft cloth. You may use moist soft cloth to remove stains when necessary.
Apply only proper amount of mild neutral detergent for obstinate stains. Please
note that never use Acryl dissolving solvent or Polycarbonate dissolving
solvent. You may apply ammonia-based glass cleaner only on the screen
surface.
Risk of Explosion If Battery Is Replaced By An Incorrect Type
Dispose Of Used Batteries According To Local Regulations
CAUTION
Part 2
9
INTRODUCTION
PRODUCT PICTURES FOR Gen 7 BASE STAND
Gen 7 Base
Front View Rear View
4
Control Panel
8
1
2
3
5
7
6
10
Side View
11
Part 3
15
Base Stand and Bottom View
Gen 7 Base
14
13
12
PARTS IDENTIFICATION
1. Main Unit
2. LCD touch panel
3. Power indicator
4. Gen 7 base stand
5. Hinge for LCD terminal
6. HDD cover
7. Touch power switch
8. Brightness adjust touch button “+”
9. Brightness adjust touch button “-”
10. I/O plate cover
11. Peripheral side mount cover
12. Cable exit
13. Base stand
14. Compression lock for base stand cover
15. Bottom plate
16. Rubber feet with bottom plate fixing screw
17. 2nd HDD cover
17
16
Part 4
B
E
G H I
I/O Plate View
D
F
A) COM1 (DB9) port
B) COM2 (DB9) port
C) COM3 (DB9) port
D) COM4 (RJ45) port
E) USB0~3 port
F) LAN1~2 port
G) VGA port
H) CR port
I) UPS BAT port
J) 1 x DC IN power connector