Posey 3050, 3052, 3053, 3060, 3063 Product Instructions

...
Page 1
APPLICATION INSTRUCTION SHEET
ADDITIONAL S AFETY
INSTRUCTIONS ON
OTHER SIDE
POSEY® JACKETS & VESTS
DESCRIPTION OF PRODUCT: Versatile jackets and vests
with tie ends. For bed or chair application.
Applicable Products:
3050, 3052, 3053, 3060, 3063,
3070, 3350, 3353, 3360, 3370
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE OR USE BY OR ON ORDER OF A PHYSICIAN.
INDICATIONS:
- Patients who are assessed to be at risk of a fall which could result in injury.
- Patients who require a positioning product to assist medical treatment.
CONTRAINDICATIONS:
Contraindications include, but are not limited to the following conditions:
- Aggressive, combative, agitated, or suicidal patients.
- Patients with ostomy, colostomy, G-Tubes, Hernias, severe Cardio Obstructive Pulmonary Disease (COPD), those with post-surgery incisions that might be compromised by the pressure from a restrictive product, or those with monitoring equipment, tubes or lines that might be compromised by rubbing against a restraint.
- Discontinue use immediately if the patient is able to slide forward or down underneath the device. ey could slide far enough under the device to become suspended, resulting in chest compression and suffocation. Posey products with a pelvic piece are designed to help prevent sliding. Products without a pelvic piece between the legs will not hinder sliding as effectively. See your Posey catalog for other more suitable products to help prevent sliding.
ADVERSE REACTIONS:
Severe emotional, psychological, and physical problems may occur if a patient’s movement is severely limited. e patient may become agitated if the device is uncomfortable or severely limits movement. Request assistance from a qualified medical authority to try to find a less restrictive alternative product or intervention.
Straps must always be snug, but not interfere with breathing. You should be able to slide your open hand (flat) between the device and the patient. Make sure straps do not slide in any direction, changing position of device.
All siderails should be HBSW compliant and MUST be in the up position when using restraints. If necessary, use a siderail cover, especially with split siderails, to prevent the patient’s body from going under, around, through or between the siderails.
After applying a restrictive product, always monitor to make sure the patient is not able to slide down, or fall off the chair seat or mattress. Make sure straps are secured at a juncture of the
© 2007 J.T. Posey Company. All rights reserved. (Ref: 97)
frame and will not slide in any direction, changing position of device. If their body weight becomes suspended off the chair or the mattress, chest compression and suffocation could result. Restraints with pelvic pieces may be necessary to reduce sliding down or pulling the restraint off over their head.
APPLICATION INSTRUCTIONS: CHAIR
Put the Jacket on with the opening in the back, and close with the zipper, ties, or hook and loop closures. e side seams should be under the arms. Take the straps down the side of the chair, over the hips at a 45 degree angle, and secure underneath the seat out of the patient’s reach. “Snug up” tightness by pulling strap around back post, cross and twist before securing. e patient's hips should be against the back of the chair.
Straps should always be snug, but not interfere with breathing. You should be able to slide your open hand (flat) between the device and the patient.
APPLICATION INSTRUCTIONS: BED
Put the Jacket on with the opening in the back and
A patient in a supine position who cannot sit up requires extra vigilance. Should the patient vomit, he/she could aspirate his/her vomitus and suffocate. Monitor constantly and be prepared to intervene at the first sign of danger.
LAUNDERINg INSTRUCTIONS:
is product was designed to be washed under CDC recommendations for linen soiled with blood or bodily fluids:
close with the zipper, ties or hook and loop fastener. e side seams should be under the arms. Secure the straps with quick-release knots to the movable part of the bed frame at waist level out of the patient's reach.
Straps should always be snug, but not interfere with breathing. You should be able to slide your open hand (flat) between the device and the patient.
is Jacket does NOT allow the patient to turn over in bed. If turning is desired, check your Posey Catalog for more appropriate products.
NOTE: Agitated patients may pull aggressively against the device, breaking the quick-release buckle. With agitated patients, it may be necessary to
Close the hook and loop closure before washing to prevent lint buildup. Use stiff brush to remove lint buildup from normal use. Test for secure hold before each use.
Lower temperature washing and drying cycle for non-contaminated linen will prolong product life.
Zip up the product before laundering and turn inside out to protect zipper.
Fasten all buckles to minimize damage during wash and dry cycle.
Inspect buckles regularly and discard if cracked. Do not put buckles through extractors.
wrap the connecting strap (from the device) once around the movable part of the bed frame (as shown in fig. 1) before attaching the buckle. e strap will absorb the stress of the pulling, and will help protect the buckle from breakage.
SIZES: Small, Medium and Large in all fabrics. X-Small and X-Large avail­able in some fabrics.
ADULT JACkETS: (wITH SLEEvES) w/zIPPER w/ HOOk & LOOP
Cotton/poly print 3350 3370 Breezeline mesh 3353
(wITH SLEEvES) w/zIPPER & qUICk-RELEASE BUCkLE ON STRAPS
Cotton/poly print 3360
(wITHOUT SLEEvES) w/zIPPER w/HOOk & LOOP
Cotton/poly print 3050 3070 Flame retardant 3052 Breezeline mesh 3053
(wITHOUT SLEEvES) w/zIPPER & qUICk-RELEASE BUCkLE ON STRAPS
Cotton/poly print 3060 Breezeline mesh 3063
J.T. Posey Company •
5635 Peck Road, Arcadia, CA 91006-0020 USA
Phone: 800-447-6739 • Fax: 800-767-3933 • Web: www.posey.com
For clarity of application illustration, bed rails do not have the recommended HBSW compliant padding. See Posey catalog for more details.
Fig. 1
I9204 050307
Page 2
Safety Information for the Use of Posey Torso and Limb Restraining Products
Ý
WARNING: Monitor patients appropriately per your facility’s policy!
Inappropriate and/or incorrect usage of any restrictive product may result in serious injury or death. e Posey Company recommends the following steps before any restrictive product is used:
•
Identify the patient’s symptoms.
•
Determine and remove, if possible, the cause of the symptoms. is may include catering to individual needs and customary routines, increased rehabilitation and restorative nursing, modifying the environment and increased supervision.
•
If the cause cannot be determined and removed, attempt alternative treatments under proper medical supervision.
•
A restraint should be used only when practicable alternatives have failed. e least restrictive device that will protect the patient and others should be selected and used for the shortest time while less restrictive alternatives are sought. It is critical that the appropriate restraint is selected and sized properly (See sizing table).
•
Follow the directions on the Application Sheet accompanying each product.
#1 Posey restraints are labeled: Caution:
Federal law (USA) restricts this device to sale by or on order of a physician. All staff should receive proper
inservice training so products are applied in accordance with the manufacturer’s instructions, state and federal regulations and the facility’s policies and procedures. Posters, Videos and Inservice materials are available free from the Posey Company.
#2 Restrictive products
should only be used
within the carefully
defined and documented parameters of the patient’s Individualized Care Plan (ICP), which addresses (but is
not limited to) restorative nursing, patient release, and pressure sore prevention. The ICP is created after an assessment by an interdisciplinary team which may represent (but is not limited to) PT, OT, Nursing, the Physician, and Social Services.
#3 NEVER use a Posey
product as a seat belt
in a moving vehicle.
Posey products are not designed to withstand the force of a crash.
#4 DO NOT expose any Posey Product to open fire, flame, or contact with smoking materials.
Components such as fabric, webbing, thread, etc. are susceptible to ignition and burning. The facility’s smoking/no smoking policy should be vigorously enforced. Flame retardant fabric is available on request.
#5 Never crisscross the straps of a Posey Vest/ Jacket in back of the patient unless there is
a positioning slot in the rear of the product. Any restraint applied incorrectly and/or worn backwards may cause strangulation or injury.
#6 Secure straps of restrictive products out of the patient’s reach at a juncture
of the movable part of the bed frame at waist level so the device will not tighten or loosen when any section of the bed is raised or lowered. Make sure the strap will
not slide in any direction, changing position of the device.
#7 After applying a restraint or self-release product; always put all
side rails in the UP position. Side rail covers
and gap protectors, especially with split side rails, may be required to keep the patient on top of the mattress, and avoid entrapment zones. Use HBSW compliant side rails.
If the patient’s body weight becomes suspended off the mattress by going under, around, over, through or between the side rails, chest
compression and suffocation could result. Restraints with pelvic pieces may be necessary to reduce sliding down or pulling the restraint over their head.
#8 Hips should be held securely against the back of the chair whenever any type of restrictive product is used. The straps should
be at 45 degrees over the hips and secured under the seat out of the patient’s reach. Make sure straps are secured at a juncture of the frame and will not slide in any direction, changing position of the device. Use extreme caution with all cushions. If dislodged, patient injury could occur (see #9).
#9 Monitor to make sure the patient is not able to slide down, or fall off the chair seat. If their body weight
becomes suspended off the chair seat, chest compression and suffocation could result. Restraints with
pelvic pieces may be necessary to reduce sliding down or pulling the restraint over their head.
#10 Straps must always be snug, but not interfere with breathing. You should be able
to slide your open hand (flat) between the device and the patient. Make sure straps do not slide in any direction, changing position of device.
#11 Always use quick-releasing ties that do not slip or loosen (see drawings), or
Just as patient behavior is not 100% predictable, no product is 100% foolproof under all circumstances. Patient safety requires regular reassessment and appropriate monitoring per your facility’s policy. A product that worked successfully in the past may prove inappropriate as the patient’s mental and physical health status changes. Never apply any product you feel is unsafe and consult with the proper medical authority if you feel a product is inappropriate for the patient.
buckles to secure straps - they allow easy
release in the event of accident or fire. Test to make sure knots do not slip or loosen. If knots slip or loosen, patient may slide off chair or bed, possibly resulting in patient injury or suffocation. Restraint release should be an integral part of the facility’s fire/disaster evacuation drills. Straps can be cut with scissors in an emergency.
#12 Patients in restrictive products require appropriate monitoring per your facility’s policy.
Aggressive, agitated, restless patients and/or those in danger of aspirating their vomit require constant monitoring and a systematic review and evaluation of both physical and psychological status.
#13 Inspect before use for broken stitches or parts; torn, cut or frayed straps or fabric; or hook and loop
How to Tie the Posey
Quick Release Tie
1. Wrap the attachment strap once around the movable part of the bed frame leaving at least an 8” tail. Fold the loose end in half to create a loop and cross it over the other end. Make sure straps are secured at a juncture of the frame and will not slide in any direction, changing position of device.
2. Insert the folded strap where the straps cross over each other, as if tying a shoe or making a tourniquet knot. Pull on the loop to tighten.
3. Fold the loose end in half to create a second loop.
1
2
3
fastener or locks that do not hold securely. These products could fail, resulting in injury or death. Destroy and
discard them. Straps must be long enough to secure out of the patient’s reach. DO NOT alter products.
4. Insert the second loop into the first loop.
4
#14 Do not use Posey
products on toilets, or on
any type of furniture which
does not allow application
as directed in the product
5. Pull on the loop to tighten.
5
application sheet. Posey limb and torso restraints should NOT be used at home.
Sizing Table for Posey Products
Always use the proper size product. Products that are too small or
large compromise patient comfort and safety and should not be used.
BINDING COLOR SIZE WEIGHT (lb./kg) CHEST (in./cm)
White X-Small 60-90/27-41 28-34/71-86 Red Small 80-120/36-54 32-39/81-99 Green Medium 110-155/50-70 37-45/94-114 Yellow Large 145-190/66-86 43-49/109-124 Blue X-Large 180-230/82-104 47-52/119-132 Black XX-Large 220-275/110-125 50-56/127-142 Yel/Blk XXX-Large 265-305/120-139 54-60/137-152 Blu/Blk XXXX-Large 295-340/134-155 58-64/147-163
Posey Belts are not color-coded, but are sized according to this table. Flame-retardant fabric is available on request.
Weight and size measurements give a general indication of the proper size. Individual physical characteristics should be taken into account before the medical authority determines the correct size. Refer to label on product for specific sizing indications.
© 2007 J.T. Posey Company. All rights reserved.97)
J.T. Posey Company •
5635 Peck Road, Arcadia, CA 91006-0020 USA
Phone: 800-447-6739 • Fax: 800-767-3933 • Web: www.posey.com
Qua lity Pr oduct s since 1937