Posey 3311, 3331, 3341 Product Instructions

Page 1
APPLICATION INSTRUCTION SHEET
ADDITIONAL S AFETY
INSTRUCTIONS ON
OTHER SIDE
POSEY® CRISS-CROSS VESTS
DESCRIPTION OF PRODUCT: A versatile vest with tie
ends. For bed or chair application.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE OR USE BY OR ON ORDER OF A PHYSICIAN.
INDICATIONS:
- Patients who are assessed to be at risk of a fall which could result in injury.
- Patients who require a positioning product to assist medical treatment.
CONTRAINDICATIONS:
Contraindications include, but are not limited to the following conditions:
- Aggressive, combative, agitated, or suicidal patients.
- Patients with ostomy, colostomy, G-Tubes, Hernias, severe Cardio Obstructive Pulmonary Disease (COPD), those with post-surgery incisions that might be compromised by the pressure from a restrictive product, or those with monitoring equipment, tubes or lines that might be compromised by rubbing against a restraint.
- Discontinue use immediately if the patient is able to slide forward or down underneath the device. ey could slide far enough under the device to become suspended, resulting in chest compression and suffocation. Posey products with a pelvic piece are designed to help prevent sliding. Products without a pelvic piece between the legs will not hinder sliding as effectively. See your Posey catalog for other more suitable products to help prevent sliding.
ADVERSE REACTIONS:
Severe emotional, psychological, and physical problems may occur if a patient’s movement is severely limited. e patient may become agitated if the device is uncomfortable or severely limits movement. Request assistance from a qualified medical authority to try to find a less restrictive alternative product or intervention.
Straps must always be snug, but not in­terfere with breathing. You should be able to slide your open hand (flat) between the device and the patient. Make sure straps do not slide in any direction, changing position of device.
All siderails MUST be in the up position when using restraints. If necessary, use a siderail cover, especially with split sid­erails, to prevent the patient’s body from going under, around, through or between the siderails.
After applying a restrictive product, always monitor appropriately per facility policy to make sure the patient is not able to slide down, or fall off the chair seat or mattress. Make sure straps are secured at a juncture of the frame and will not slide in any direction, changing position of device. If their body weight becomes suspended off the chair or the mattress, chest compression and suffocation could result. Restraints with pelvic pieces may be necessary to reduce sliding down or pulling the restraint off over their head.
Applicable Products:
REF
3311, 3331, 3341
APPLICATION INSTRUCTIONS: BED
Put the Vest on with the "V" neck in front only. Crisscross the straps, making sure to thread the left strap through the slot, and secure the ends to the movable part of the bed frame at waist level, out of the patient’s reach. e patient should be able to breath comfortably.
Straps should always be snug, but not interfere with breathing. You should be able to slide your open hand (flat) between the device and the patient. Make sure straps are secured at a juncture of the bed frame and will not slide in any direction, changing position of device. e Posey Quick-Release Tie (see reverse side) should be used to attach straps to the movable part of the bed frame.
is Vest does not allow the patient to turn over in bed. If turning is desired, check your Posey catalog for other products.
Always apply Vest with "V" neck in front. If the patient becomes suspended off the mattress, chest compression and suffocation could result. Restraints with pelvic pieces may be necessary to reduce sliding down.
LAUNDERINg INSTRUCTIONS:
is product was designed to be washed under CDC recommendations for linen soiled with blood or bodily fluids:
Lower temperature washing and drying cycle for non-contaminated linen will prolong product life.
© 2006 J.T. Posey Company. All rights reserved. (Ref: 97)
APPLICATION INSTRUCTIONS: CHAIR
Put the Vest on with the "V" neck in front only. Crisscross the straps, making sure to thread the left strap through the slot, and secure the straps over the hips at a 45 degree angle underneath the seat, out of the patient’s reach. “Snug up” tightness by pulling strap around back post, cross and twist before securing. e patient's hips should be against the back of the chair. Make sure straps are secured and will not slide in any direction, changing position of the device. e Posey Quick-Release Tie (see reverse side) should be used to attach straps to the chair.
Straps should always be snug, but not interfere with breathing. You should be able to slide your open hand (flat) between the device and the patient.
Always apply Vest with "V" neck in front. If the patient becomes suspended off the chair, chest compression and suffocation could result. Restraints with pelvic pieces may be necessary to reduce sliding down.
Posey Criss Cross Vests;
A patient in a supine position who cannot sit up requires extra vigilance. Should the patient vomit, he/she could aspirate his/her vomitus and suffocate. Monitor constantly and be prepared to intervene at the first sign of danger.
J.T. Posey Company •
5635 Peck Road, Arcadia, CA 91006-0020 USA
Small, Medium, Large
REF
3311, Breezeline Mesh
REF
3331, Cotton
REF
3341, Poly/Cotton
Phone: 800-447-6739 • Fax: 800-767-3933 • Web: www.posey.com
EC REP
Overall Size Strap Length
S 58” M 61” L 64”
MDSS Burckhardtstr. 1, D-30163, Hannover, Germany
I9203 032806
Page 2
Safety Information for the Use of Posey Torso and Limb Restrictive Products
45˚
WARNING: Monitor patients appropriately per
pelvic pieces may be necessary to reduce sliding down or pulling the restraint over their head.
your facility’s policy!
Inappropriate and/or incorrect usage of any restrictive product may result in serious injury or death.
e Posey Company recommends the following steps before any restrictive product is used:
•
Identify the patient’s symptoms.
•
Determine and remove, if possible, the cause of the symptoms. is may include catering to individual needs and customary routines; increased rehabilitation and restorative nursing; modifying the environment; and increased supervision.
•
If the cause cannot be determined and removed, attempt alternative treatments under proper medical supervision.
•
A restraint should be used only when practicable alternatives have failed. e least restrictive
device that will protect the patient and others should be selected and used for the shortest time while less restrictive alternatives are sought. It is critical that the appropriate restraint is selected.
•
Follow the directions on the Application Sheet accompanying each product.
#1 Posey restraints are labeled: Caution:
Federal law (USA) restricts this device to sale by or on order of a physician.
All staff should receive proper
inservice training so products are applied
of the movable part of the bed frame at waist level so the device will not tighten or loosen when any section of the bed is raised or lowered. Make sure the strap will
not slide in any direction, changing position
of the device. in accordance with the manufacturer’s instructions, state and federal regulations and the facility’s policies and procedures. Posters, Videos and Inservice materials are available free from the Posey Company.
side rails in the UP position. Side rail covers
#7 After applying a restraint or self-release product; always put all
and gap protectors, especially with split side
#2 Restrictive products should only be used within the carefully
rails, may be required to keep the patient on
top of the mattress, and avoid entrapment
zones.
defined and documented parameters of the patient’s Individualized Care Plan (ICP) which addresses (but is
not limited to) restorative nursing, patient release, and pressure sore prevention. The ICP is created after an assessment by an interdisciplinary team which may represent (but is not limited to) PT, OT, Nursing, the Physician, and Social Services.
If the patient’s body weight becomes suspended off the mattress by going under, around, over, through or between the side rails, chest compression and
suffocation could result. Restraints with #3 NEVER use a Posey product as a seat belt in a moving vehicle.
pelvic pieces may be necessary to reduce
sliding down or pulling the restraint over
their head.
Posey products are not
designed to withstand the force of a crash.
#8 Hips should be
held securely against #4 DO NOT expose any Posey Product to open fire, flame, or contact with smoking materials.
Components such as fabric, webbing, thread, etc. are susceptible to ignition and burning. The facility’s smoking/no smoking policy should be vigorously enforced. Flame retardant fabric is available on request.
be at 45 degrees over the hips and secured under the seat out of the patient’s reach. Make sure straps are secured at a juncture of the frame and will not slide in any direction, changing position of the device.
the back of the chair
whenever any type of
restrictive product is
used. The straps should
Use extreme caution with all cushions. If
#5 Never crisscross the
dislodged, patient injury could occur. (see #9).
straps of a Posey Vest/ Jacket in back of the patient unless there is
a positioning slot in the rear of the product. Any restraint applied incorrectly and/or worn backwards may cause strangulation or injury.
#9 Monitor to make
sure the patient is not
able to slide down, or
fall off a chair seat.
If their body weight
becomes suspended
#6 Secure straps of restrictive products out of the patient’s reach at a juncture
off the chair seat, chest compression and suffocation could result. Restraints with
#10 Straps must always be snug, but not interfere with breathing. You should be able
to slide your open hand (flat) between the device and the patient. Make sure straps do not slide in any direction, changing position of device.
#11 Always use quick-releasing ties (see drawings) or buckles to secure straps – they
allow easy release in the event of accident or fire. Restraint release should be an integral part of the facility’s fire/disaster evacuation drills. Straps can be cut with scissors in an emergency.
restless patients and/or those in danger of aspirating their vomit require constant monitoring and a systematic review and evaluation of both physical and psychological status.
products could fail, resulting in injury or death. Destroy and discard them. Straps must
be long enough to secure out of the patient’s reach. DO NOT alter products.
limb and torso restraints should NOT be used at home without constant supervision of a licensed healthcare provider, physician’s order and an Individualized Care Plan.
BINDING COLOR SIZE WEIGHT
White X-Small 60-90/27-41 28-34/71-86 Red Small 80-120/36-54 32-39/81-99 Green Medium 110-155/50-70 37-45/94-114 Yellow Large 145-190/66-86 43-49/109-124 Blue X-Large 180-230/82-104 47-52/119-132 Black XX-Large 220-275/110-125 50-56/127-142 Yel/Blk XXX-Large 265-305/120-139 54-60/137-152 Blu/Blk XXXX-Large 295-340/134-155 58-64/147-163
Posey Belts are not color-coded, but are also sized according to this table. Flame-retardant fabric is available on request.
Weight and size measurements give a general indication of the proper size. Individual physical characteristics should be taken into account before the medical authority determines the correct size. Refer to label on
product for specic sizing indications.
Just as patient behavior is not 100% predictable, no product is 100% foolproof under all circumstances. A restraint is not a substitute for good nursing care. Patient safety requires regular reassessment and appropriate monitoring per your facility’s policy. A product that worked successfully in the past may prove inappropriate as the patient’s mental and physical health status changes. Never apply any product you feel is unsafe and consult with the proper medical authority if you feel a product is inappropriate for the patient.
How to Tie the Posey
Quick Release Tie
#12 Patients in restrictive products require appropriate monitoring per your facility’s policy.
Aggressive, agitated,
#13 Inspect before use for broken stitches or parts; torn, cut or frayed straps or fabric; or hook and loop fastener or locks that do not hold securely. These
#14 Do not use Posey products on toilets, or on any type of furniture which does not allow application as directed in the product application sheet. Posey
Sizing Table for Posey Products
Always use the proper size product. Products that are too small or
large compromise patient comfort and safety and should not be used.
1. Wrap the attachment strap once around the movable part of the bed frame leaving at least an 8” tail. Fold the loose end in half to create a loop and cross it over the other end. Make sure straps are secured at a juncture of the frame and will not slide in any direction, changing position of device.
2. Insert the folded strap where the straps cross over each other, as if tying a shoe or making a tourniquet knot. Pull on the loop to tighten.
3. Fold the loose end in half to create a second loop.
4. Insert the second loop into the first loop.
5. Pull on the loop to tighten.
(lb./kg) CHEST (in./cm)
1
2
3
4
5
J.T. Posey Company •
Phone: 800-447-6739 • Fax: 800-767-3933 • Web: www.posey.com
© 2006 J.T. Posey Company. All rights reserved.97)
5635 Peck Road, Arcadia, CA 91006-0020 USA
Qua lity Pr oduct s since 1937
EC REP
MDSS Burckhardtstr. 1, D-30163, Hannover, Germany
I9200 021306
Loading...