Posey 2532A, 2551A Application Instructions

Posey® Limb Holders 2532A, 2551A
Application Instructions for Wrist and Ankle
DESCRIPTION OF PRODUCT: Limb holder for limiting limb movement. For bed and stretcher use only.
Indications for Use
Patients assessed to be at risk of disrupting life-saving treatments (e.g., pulling tubes or lines) or in danger of injury to themselves or to others.
Follow your hospital’s restraint policies and procedures which are in compliance with CMS guidelines and state laws.
Contraindications
Do not use this device with someone who has continued highly aggressive or combative behavior, self-destructive behavior, or deemed to be an immediate risk to others or to self.
Application Instructions
Follow these steps to apply device (repeat steps 1-7 on each side): 1a. Attach the female end of the quick-release
buckle (short strap) to the frame that
Fig. 1
moves with the patient (Fig. 1), out of the patient’s reach (do not attach to side rail or head/footboard). You may also wrap the connecting strap once around the frame to move the buckle out of the patient’s reach. Secure by feeding the female end through the loop in the strap.
1b. Insert the male end of the connecting strap into the female end
of the short strap. Listen for a “snapping” sound. Pull rmly on the
straps to ensure a good connection. Move the slide buckle next to the male end of the quick release buckle to prevent the strap
Fig. 2
Move Slide
Move Slide
Buckle next to
buckle next to Quick-Release
Quick-Release
buckle
Buckle
from loosening (Fig. 2).
2. Wrap the limb holder cu around the patient’s wrist/ankle so the buckle and connecting strap is on the ulnar side of the
Fig. 3
wrist or lateral malleolus of the ankle. (Fig 3).
3. Secure the hook-and-loop fastener. Slide
ONE nger (at) between the cu and the
inside of the patient’s wrist/ankle to ensure
proper t (Fig 4). The strap must be snug, but
Fig. 4
not compromise circulation.
4. Close the quick-release buckle on the cu.
Insert ONE nger (at) under the buckle and
pull the strap snug, but not so tight as to
Fig. 5
restrict circulation (Fig 5).
5. Release the quick-release buckle, twist buckle 180°, and reconnect (Fig 6). Listen for a “snapping” sound.
6. Attach the “hook” end of the cu strap to the
Fig. 6
“fuzzy” backing on the cu to keep the quick-
release buckle from sliding (Fig 7).
7. Adjust the strap to allow for desired freedom of movement, without compromising patient or caregiver safety.
Fig. 7
To remove cus: Unsnap quick-release buckles and release hook-and-loop fasteners. Quick-Release Anchor Strap: Remove Anchor
Strap from frame aer use. Do not reuse quick-
release buckles, and do not mix male and
female ends from dierent products.
Posey Limb Holders
REF
REF
To limit lower limb range of motion for legs:
1. Attach the cu that is secured to the bottom
right side of the frame to the le ankle.
2. Crisscross the straps and attach the cu secured to the bottom le side of the frame
to the right ankle.
3. Adjust connecting straps as necessary
Precautions
Avoid using on a patient with a dislocation or fracture on the restrained
limb, or if an IV or wound site could be compromised by the device.
Check the patient regularly to ensure that circulation is not impaired.
Serious injury may occur if the cuffs restricts circulation when the limb
holder is applied.
Before each use, check cuffs and straps for cracks, tears,
and/or excessive wear or stretch, broken buckles or locks, and/or that hook-and-loop adheres securely as these may allow patient to
remove cuff. Discard if device is damaged or if unable to lock.
needed (See Posey Catalog):
»
If the patient pulls violently against the bed straps.
»
To reduce the risk of the patient getting access to the line/
wound/tube site.
» To prevent the patient from ailing or bucking up and down and
causing self-injury.
Bed Safety
Refer to the Food and Drug Administration (FDA) for the most recent Hospital Bed Safety Guidelines as well as the Bed Manufacturer for their Instructions for Use.
2532A
2532A Quick-Release Limb Holders, single strap with
quick-release connecting strap
2551A Quick-Release Quilted Limb Holders, single strap with
quick-release connecting strap
Additional or different body or limb restraints may be
Rx ONLY
ADDITIONAL SAFETY AND LAUNDERING
INSTRUCTIONS ON OTHER SIDE
Posey Products, LLC • 5635 Peck Road, Arcadia, CA 91006-0020 USA Phone: 1.800.447.6739 • Fax: 1.800.767.3933 • www.posey.com
EC REP
MDSS GmbH
Schigraben 41 D-30175 Hannover, Germany
Safety Information for the use of Posey
®
Restraining Products
WARNING: ALWAYS Monitor patients per facility
policy. Improper application or use of any restraint may result in
rious injury or death.
se
RX ONLY. Federal law (USA) restricts this device to sale by or on order of a physician. For use in a licensed healthcare facility only.
STAFF TRAINING: Posey offers training aids at no charge. Contact Posey
online at www.posey.com or call toll-free at 1.800.447.6739.
BEFORE APPLYING ANY RESTRAINT:
Follow your hospital’s restraint policies and procedures which are in compliance with CMS guidelines and state laws.
ADDITIONAL WARNINGS:
1. ALWAYS monitor patient per facility policy. Be aware that constant monitoring may be required for:
Aggressive or agitated patients; and
Patients in a supine positon; ensure that being in this position would not cause any complications for those who are at risk of vomiting while being restrained.
2. NEVER alter or repair this product. ALWAYS Inspect before each use: Check for broken stitches or parts; torn, cut or frayed material; or locks, buckles, or hook-and-loop fasteners that do not hold securely. DO NOT use soiled or damaged products. Doing so may result in serious injury or death. Dispose of damaged products per facility policy for BIOHAZARDOUS material.
3. ALWAYS secure straps to a part of the frame
that moves with the patient (not foot/head board or siderails, out of the patients reach, using quick-release ties (see drawing below) or buckles. These allow easy release in the event of
an accident or re. Test to make sure straps cannot tighten, loosen, or slip and create excess slack. If this occurs, the patient may slide o the chair or bed, increasing the risk of serious injury or suocation. Restraint release is an important part of facility re and disaster drills. Straps can be cut with scissors in an emergency.
4. NEVER secure restraint strap to side rail or head/foot board.
5. NEVER use Posey products on toilets, or on any chair
or furniture that does not allow proper application as directed in the Application Instructions. DO NOT use at home.
6. NEVER expose this product to open ame, re, smoking materials, or high heat sources. Some products may melt or ignite and burn. The facility smoking/no smoking policy should be strictly enforced.
7. NEVER use a Posey product as a seat belt in a moving vehicle. Posey products are not designed to withstand the force of a crash or sudden stop.
8. Test Zippers or hook-and-loop fasteners before each use. DISCARD device if it does not fasten securely.
LAUNDERING INSTRUCTIONS (if applicable):
Fasten all buckles and locks to reduce risk of damage during wash and dry cycles. DO NOT put buckles or locks through extractors. For maximum life, launder in a laundry bag.
Before laundering, zip up and turn the product inside out to protect zipper.
Hook-and-loop fasteners may collect lint aer repeated use or laundering, reducing grip strength. Fasten the “hook” to the “loop” before laundering to help prevent lint buildup. As needed, use a sti-bristle brush to remove lint from the “hook” side.
These products, other than foam products, can be machine washed under CDC* guidelines for material soiled with blood or bodily uid.
For non-contaminated material, use lower temperature wash and dry cycles to extend product life.
For foam products:
BIOTHANE:
Sanitize by submerging the entire product in 70% isopropyl alcohol for 10 minutes; or
Apply an OSHA approved intermediate level disinfectant per manufacturer instructions. Aer cleaning, products MUST be rinsed with water to remove any residual chemicals.
Make sure products are completely dry before use.
Stainless Steel Locks: Posey recommends that locks be treated with a dry­lm lubricant (silicone) aer each cleaning. For best results, spray a small amount into the lock. Work the action of the lock with a key several times to ensure that all the surfaces are well lubricated.
STORAGE AND HANDLING:
This device is designed for use in normal indoor environments.
This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.
*www.cdc.gov
HOW TO TIE THE POSEY QUICK-RELEASE TIE
1 2 3 4 5
1. Wrap the strap once around a movable part of the bed frame leaving at least an 8" (20 cm) tail. Fold the loose end in half to create a loop and cross it over the other end.
2. Insert the folded strap where the straps cross over each other, as if tying a shoelace. Pull on the loop to tighten.
3. Fold the loose end in half to create a second loop.
4. Insert the second loop into the rst loop.
5. Pull on the loop to tighten. Test to make sure strap is secure and will not slide in any direction.
6. Repeat on other side. Practice quick-release ties to ensure the knot releases with one pull on the loose end of the strap.
Posey Products, LLC • 5635 Peck Road, Arcadia, CA 91006-0020 USA Phone: 1.800.447.6739 • Fax: 1.800.767.3933 • www.posey.com
EC REP
MDSS GmbH
Schigraben 41 D-30175 Hannover, Germany
I9200B REV D 120418© Posey Products, LLC. All rights reserved.