WATER COOLED A.C. SWITCH 2-2WI-600
Repetitive voltage up to V
Maximum continuous RMS current 730 A
Surge current 5.6 kA
FINAL SPECIFICATION
giu 02 - ISSUE : 01
Symbol Characteristic Conditions
Tj
[°C]
Value Unit
BLOCKING
VDRM/VRRM
Repetitive peak voltage 125 1600 V
V
DSM/VRSM
Non-repetitive peak voltage 125 1700 V
I
DRM/IRRM
Repetitive peak current 125 30 mA
CONDUCTING
I T(RMS) Maximum continuous RMS current 50 Hz, Q = 4 l/min, water temperature = 40°C 730 A
I
TSM Surge on-state current 125 5.6 kA
I² t I² t 157 x1E3 A²s
V
TM Max peak on-state voltage
ITM = 1032 A
125 1.70 V
V
T(TO) Threshold voltage 125 1.00 V
r
T On-state slope resistance 125 0.680
mΩ
SWITCHING
di/dt Critical rate of rise of on-state current, min.
From 75% VDRM up to 1650 A, gate 10 V - 5 Ω
125 200 A/µs
dv/dt Critical rate of rise of off-state voltage, min. Linear ramp up to 70% of VDRM 125 500 V/µs
GATE
V GT Gate trigger voltage VD=5 V 25 3.5 V
I
GT Gate trigger current VD=5 V 25 200 mA
P
GM Max peak gate power Pulse width 100 µs 25 75 W
MECHANICAL
R th(j-w) Thermal impedence, DC Junction to water (double side cooled) 0.25 °C/W
V
ins(RMS) Insulation voltage rms 1 min 25 2.5 kV
Press Max water pressure 10 bar
Tj
max Max operating junction temperature 125 °C
Weight 5050 g
Thermal switch open 63°C, cloused 50°C. 10 A - 250 V
OUTLINE
W0 DEVICES TYPE: AT505
A98
B70
ORDERING INFORMATION : 2-2WI-600 S 16
standard s