1. General Description
The POS-1L+ is devices designed for broadcasting parameter and control FM transmitter
system via Local Area Network or Internet
This device has LAN 10/100 Mbits/Sec . when connect it in your network. You can monitor
parameter of FM transmitter system and control it in real time s uch change power transmission, off
power, etc. on anywhere if your can connected on your network
2. Installation and use Description
This chapter contains the necessary information for installing and using the machine. In the
event any aspects are not completely clear, for example when using the machine for the first time,
we recommend you carefully read the entire description contained in this manual.
2.1 Preparation
Unpack the POS-1L+ and before doing any other operation, be sure it has not been
damaged during transport. In particular check that all the connectors are in perfect condition.
The main fuse can be accessed from the outside on the rear panel. Extract the fuse carrier
with a screwdriver to check its integrity or for replace ment, if necessary. The fuse to be used is this
type 30A @220VAC
Check that the POS-1L+ switches are in the "OFF" position. The POS-1L+ has one switch
for the mains power supply cable and completely interrupts the machine's mains power supply.
Connect the AC Output to Exciter and Amplifier.
Connect the RS-232 cable From Exciter to DATA IN 1.
Connect the RS-232 cable From Amplifier to DATA IN 2.
Connect the LAN cable.
Connect the AC Input cable.
2.2 Use
Check that the POS-1L+ switches are in the "OFF" position.
Check that the Exciter switches are in the "ON" position.
Check that the Amplifier switches are in the "ON" position.

POS-1L+
User manual V1.2 www.posbroadcast.com
4 of 10
2.3 Settings
POS-1L+ can be configuration via Internet Explorer. Before setup POS-1L+ please connect
POS-1L+ and Computer on same Network. Power on POS-1L+
Open Internet Explorer and enter http://
and follow with IP Address of POS-1L+ on address
bar
• Enter Username and Password for access. Default Username: “admin” no password.
• After you can access on page will display as picture below
Figure 1 Main Page

POS-1L+
User manual V1.2 www.posbroadcast.com
5 of 10
• Click on [ Login ] link and enter username / password
Figure 2 Login
• After enter, click on Login button if username / password are correct. Login button will go
to disabled stage and Logout button will go to enabled as picture below.
Figure 3 Login
• Click on main link for go to main page

POS-1L+
User manual V1.2 www.posbroadcast.com
6 of 10
• Click on [ IP Configuration ] link page will show as picture below
Figure 4 IP Configuration
• Enter IP address and network parameter, after complete click on Change button, devices
will save parameter and reboot please wait about 30 seconds.
• Setup Station Name by click [ Station Name Setup ] on main page , page will show as
picture below
• Enter station name ( Max. 50 Character ) and click on Save button

POS-1L+
User manual V1.2 www.posbroadcast.com
7 of 10
• Click on main link for go to main page and click [ AC Power Control ]
Figure 5 AC Power Control
• Click on Check box and click on Save & Apply for turn on AC power of Exciter and
Amplifier
• Click on main link for go to main page and click [ FM Exciter Setup ]
Figure 6 FM Exciter Setup
• Enter parameter for Exciter and click on Se t button, POS-1L+ will send setup parameter
to Exciter and user can see result on [ Monitor Station ] Page

POS-1L+
User manual V1.2 www.posbroadcast.com
8 of 10
• Click on main link for go to main page and click [ FM Amplifier Setup ]
Figure 7 FM Amplifier Setup
• Enter parameter for Amplifier and click on Set button, POS-1L+ will send setup
parameter to Amplifier and user can see result on [ Monitor Station ] Page
• For mon itor parameter of exciter and amplifier on line click [ Monitor Station ] on main
page
Figure 8 Monitor Status
*Parameter will automatic re fresh every 10 seconds but if you want to manual refresh click
on Refresh button

POS-1L+
User manual V1.2 www.posbroadcast.com
9 of 10
3. External Description
This chap ter reports the elements of the front and rear panels of the P OS-1L+ with a brief
description of each of them.
3.1 Front Panel
[1] AIR FLOW Gri d for the intake of the air flow of the forced ventilation
[2] POWER ON/OFF switch.
[3] ON Green LED, light when the POS-1L+ is working.
[4] LAN Green LED, light when the send or receive data via LAN.
[5] STATUS Green LED, light when the receive data from Exciter or
Amplifier.
[6] CONTROL Green LED, light when Exciter and Amplifier power on.
3.2 Rear Panel
[1] MAIN INPUT Mains supply terminal, 180 - 240V 50-60 Hz.
[2] FUSE Fuse holder. Use a screwdriver to access the fuse Contains
the general protection fuse rated 30 A.
[3] MAIN OUTPUT Output supply terminal for supply to Exciter and Amplifier.
[4] LAN RJ-45 LAN connecter use for monitor and control.
[5] DATA IN 1 RS-232, DB-9, for connect with Exciter.
[6] DATA IN 2 RS-232, DB-9, for connect with Amplifier.
[7] DATA OUT 1 RS-232, DB-9, for Maintenance.
[8] DATA OUT 2 RS-232, DB-9, reserve.

POS-1L+
User manual V1.2 www.posbroadcast.com
10 of 10
4. Technical Specifications
4.1 Physical specifications
Panel size 483 mm (19”) x 44 mm (1 3/4”) (1U)
Depth 240 mm (9 1/2”)
Weight 1.5 Kg
Working Temperature 0 °C - 50 °C
4.2 Electrical specifications
A.C. power supply ≅ 180 V - 240 V 50 – 60 Hz
A.C. output current Max. 30 A
LAN Connection 10/100 MBits/Sec.