IMPORTANT
Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations.
Model H451CS
PROFESSIONAL POWER TOOLS
Shown with optional portability kit
2 — ENG
This product is equipped with a spark arresting muffler. If the product will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of California. It is a violation of California statutes section 130050 and/or sections 4442 and 4443 of the Cal­ifornia Public Resources Code, unless the engine is equipped with a spark arrestor, as defined in section 4442, and maintained in effective working order. Spark arresters are also required on some U. S. Forest service land and may also be legally required under other statutes and ordinances.
This product may contain chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm. This warning is given in compliance with California Proposition 65, as detectable amounts of chemicals subject to proposition 65 may be contained in this product.
SPECIFICATION
MODEL H451CS
HORSE POWER 9.0 RATED/SURGE WATTS 4500/9000 VOLTAGE 120/240 AMPERAGE 37.5A/18.8A PHASE SINGLE FREQUENCY 60 Hz ENGINE SPEED 3600 RPM MAX. AMBIENT TEMP. 104° F FUEL CAPACITY 4 GALLONS RUN TIME @ 50%/100% 10.6/5.2 HRS
3 — ENG
WARRANTY
Porter-Cable Corporation
4825 Highway 45 North
P.O. Box 2468
Jackson, TN 38302-2468
1-888-559-8550
PORTER-CABLE CORPORATION warrants to the original purchaser that each new electric generator and service part is free from defects in material and workmanship, and agrees to repair or replace under this warranty any defective product or part as follows from the original date of purchase.
2 YEARS – Limited warranty on electric generator alternators and 1 year limited warranty on all other parts.
90 Days – Service parts
Engine warranties are the responsibility of the engine manufacturer. Warranties of merchandise sold by Porter-Cable which has been manufactured by and identified as the product of another company are the responsibility of the manufacturer of that product.
THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER
Products sold damaged or incomplete, sold “as is,” sold reconditioned, or used as rental equipment.
Delivery, installation, or normal adjustments explained in the owner’s manual.
Damage or liability caused by shipping, improper handling, improper installation, improper maintenance, improper mod-
ification, or the use of accessories and/or attachments not specifically recommended by PORTER-CABLE for the prod­uct.
Repairs necessary because of operator abuse or negligence, or the failure to install, operate, maintain, and store the
product according to the instructions in the owner’s manual.
Damage caused by cold, heat, rain, excessive humidity, corrosive environments and materials, or other contaminants.
Expendable items that become worn during normal use such as fuel filters, air cleaners, spark plugs, and engine oil.
Cosmetic defects that do not interfere with product functionality.
Freight costs from customer to Porter-Cable.
Repair and transportation costs of products or parts determined not to be defective.
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM
ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limita­tion of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limi­tations on how long an implied warranty lasts, so the above limitations may not apply to you.
WARRANTY SERVICE is available by delivering or shipping the defective product or part to any Porter-Cable authorized
warranty service location. To determine the nearest authorized warranty service location, call the toll free number, 1-888­559-8550, 24 hours a day, 7 days a week. Specific instructions regarding servicing arrangements and scheduling may vary depending on the type and size of the product and the availability of repair parts.
DO NOT return the defective product to the retailer.
Retain the original cash register sales receipt as proof of purchase for warranty work.
Purchasers should contact Porter-Cable directly if they do not receive satisfactory results from the authorized warranty
service center.
4 — ENG
Attempting to connect generator directly to the electrical system of any building structure.
Back feeding electricity through a building’s electrical system to the outside utility feed lines could endan­ger repair persons attempting to re­store service.
Attempting to connect to the incom­ing utility service could result in elec­trocution.
Restoration of electrical service while the generator is connected to the incoming utility could result in a fire or serious damage if an isolator switch is not installed.
Failure to use a double throw transfer switch when connecting to a struc­ture's electrical system can damage appliances and WILL VOID the man­ufacturer's warranty.
Never backfeed electricity through a structure's electrical system.
To connect to a structure's electri­cal system in a safe manner, always have a Double-Throw Transfer Switch installed by a quali­fied electrician and in compliance with local ordinances. (When in-
stalling a Double-Throw Transfer Switch, a minimum of 10 gauge wiring must be used.)
HAZARD
HOW TO PREVENT IT
WHAT COULD HAPPEN
RISK OF ELECTROCUTION AND FIRE
When using this product basic precautions should always be fol-
lowed including the following:
• SAVE THESE INSTRUCTIONS •
IMPORTANT SAFETY INSTRUCTIONS
SAFETY GUIDELINES - DEFINITIONS
URGENT SAFETY INFORMATION - A HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A HAZ­ARD THAT MIGHT CAUSE SERIOUS INJURY OR LOSS OF LIFE.
Information for preventing damage to
equipment.
Information that you should pay special attention to.
This manual contains information that is important for you to know and un­derstand. This information relates to protecting YOUR SAFETY and PRE-
VENTING EQUIPMENT PROB­LEMS. To help you recognize this
information, we use symbols to the right. Please read the manual and pay attention to these sections.
Improper storage of extension cord
Extension cord can come into contact with hot engine parts resulting in damage. Using a damaged extension cord can result in electrocution or death.
Never fold handle over hot engine with extension cord wrapped on storage bracket.
5 — ENG
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
Use of worn, damaged, under­sized or ungrounded extension cords.
Placing generator on or against highly conductive surface, such as a steel walkway or metal roof.
Improper connection of items to generator.
Operation of unit when damaged, or with guards or panels removed.
Contact with worn or damaged ex­tension cords could result in electro­cution.
Use of undersize extension cords could result in overheating of the wires or attached items, resulting in fire.
Use of ungrounded cordsets could prevent operation of circuit breakers and result in electrical shock.
Accidental leakage of electrical cur­rent could charge conductive sur­faces in contact with the generator.
Exceeding the load capacity of the generator by attaching too many items, or items with very high load ratings to it could result in overheat­ing of some items or their attachment wiring resulting in fire or electrical shock.
Attempting to use the unit when it has been damaged, or when it is not functioning normally could result in fire or electrocution.
Removal of guarding could expose electrically charged components and result in electrocution.
Inspect extension cords before use and replace with new cord if required.
Use proper size (wire gauge) cord­set for application see chart in the Assembly section of this manual.
Always use a cordset having a grounding wire with an appropri­ate grounding plug. DO NOT use an ungrounded plug.
Place generator on low conductiv­ity surface such as a concrete slab.
ALWAYS operate generator a min­imum of six feet from any conduc­tive surface.
Read the load rating chart and in­structions in the Wattage Calcula­tion section. Make sure that the summation of electrical loads for all attachments does not exceed the load rating of the generator.
Do not operate generator with me­chanical or electrical problem. Have unit repaired by an Autho­rized Service Center.
Do not operate generator with protective guarding removed.
RISK OF ELECTROCUTION AND FIRE (cont’d)
HAZARD
HOW TO PREVENT ITWHAT COULD HAPPEN
Operation of generator in rain, wet, icy, or flooded conditions.
Water is an excellent conductor of electricity! Water which comes in con­tact with electrically charged compo­nents can transmit electricity to the frame and other surfaces, resulting in electrical shock to anyone contacting them.
Operate generator in a clean, dry, well ventilated area. Make sure hands are dry before touching unit.
6 — ENG
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
RISK OF FIRE
Inadequate ventilation for generator
Use care in filling the tank to avoid spilling fuel. Make sure fuel cap is secured tightly and check engine for fuel leaks before starting engine. Move generator away from refueling area or any spillage before starting engine. Allow for fuel expansion. Keep maximum fuel level 1/2 inch below the tip of the fuel tank. Never refuel with the engine running.
Spilled fuel and its vapors can become ignited from hot surfaces or sparks.
HAZARD
HOW TO PREVENT ITWHAT COULD HAPPEN
Attempting to fill the fuel tank while the engine is running.
Sparks, fire, hot objects
Improper storage of fuel
Tampering with factory set engine speed settings.
Overfilling the fuel tank – fuel spillage.
Gasoline and gasoline vapors can become ignited by coming in contact with hot components such as the muffler, engine exhaust gases, or from an electrical spark.
Cigarettes, sparks, fires, or other hot objects can cause gasoline or gaso­line vapors to ignite.
Improperly stored fuel could lead to accidental ignition. Fuel improperly se­cured could get into the hands of chil­dren or other unqualified persons.
Materials placed against or near the generator or operating the generator in areas where the temperature exceeds 104° F. ambient (such as storage rooms or garages) can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings.
Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could re­sult in overheating of attachments and could cause a fire.
Turn engine off and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires.
Add fuel to tank in well ventilated area. Make sure there are no sourc­es of ignition near the generator.
Store fuel in a OSHA approved container designed to hold gaso­line. Store container in secure loca­tion to prevent use by others.
Operate generator in a clean, dry, well ventilated area a minimum of four feet from any building, object or wall. DO NOT OPERATE UNIT
INDOORS OR IN ANY CONFINED AREA.
Never attempt to “speed-up” the engine to obtain more perfor­mance. Both the output voltage and frequency will be thrown out of standard by this practice, endan­gering attachments and the user.