Porter-Cable D21679-008-0 User Manual

Instruction
manual
Model BS500
ESPAÑOL: PÁGINA 21 FRANÇAISE: PAGE 41
Generator
To learn more about Porter-Cable
visit our website at:
http://www.porter-cable.com
PROFESSIONAL POWER TOOLS
Copyright © 2000 PORTER-CABLE Corporation
IMPORTANT
Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations.
Model No.
Type
Serial No.
Part No. D21679-008-0
SPECIFICATION
MODEL BS500
HORSE POWER 10.0 RATED/SURGE WATTS 5000/6250 VOLTAGE 120/240 AMPERAGE 41.6/20.8A PHASE SINGLE HERTZ 60 Hz ENGINE SPEED 3600 RPM MAX. AMBIENT TEMP. 104° F FUEL CAPACITY 7 GALLON RUN TIME @ 50%/100% 10.8/7.2 HRS
This product is not equipped with a spark arresting muffler. If the product will be used around
flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of California. It is a violation of California statutes section 130050 and/or sections 4442 and 4443 of the California Public Resources Code, unless the engine is equipped with a spark arrestor, as defined in section 4442, and maintained in effective working order. Spark arresters are also required on some U. S. Forest service land and may also be legally required under other statutes and ordinances.
This product may contain chemicals known to the state of California to cause cancer, birth defects, or other
reproductive harm. This warning is given in compliance with California Proposition 65, as detectable amounts of chemicals subject to proposition 65 may be contained in this product.
2 — ENG
WARRANTY
PORTER-CABLE CORPORATION warrants to the original purchaser that each new electric generator and service part is free from defects in material and workmanship, and agrees to repair or replace under this warranty any defective product or part as follows from the original date of purchase.
2 YEARS – Limited warranty on electric generator alternators and 1 year limited warranty on all other parts. 90 Days – Service parts
Engine warranties are the responsibility of the engine manufacturer. Warranties of merchandise sold by Porter-Cable which has been manufactured by and identified as the product of another company are the responsibility of the manufac­turer of that product.
THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER
Products sold damaged or incomplete, sold “as is,” sold reconditioned, or used as rental equipment.
Delivery, installation, or normal adjustments explained in the owner’s manual.
Damage or liability caused by shipping, improper handling, improper installation, improper maintenance, improper modification, or the use of accessories and/or attachments not specifically recommended by PORTER-CABLE for the product.
Repairs necessary because of operator abuse or negligence, or the failure to install, operate, maintain, and store the product according to the instructions in the owner’s manual.
Damage caused by cold, heat, rain, excessive humidity, corrosive environments and materials, or other contaminants.
Expendable items that become worn during normal use such as fuel filters, air cleaners, spark plugs, and engine oil.
Cosmetic defects that do not interfere with product functionality.
Freight costs from customer to Porter-Cable.
Repair and transportation costs of products or parts determined not to be defective.
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- POSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
WARRANTY SERVICE is available by delivering or shipping the defective product or part to any Porter-Cable authorized
warranty service location. To determine the nearest authorized warranty service location, call the toll free number, 1-888­559-8550, 24 hours a day, 7 days a week. Specific instructions regarding servicing arrangements and scheduling may vary depending on the type and size of the product and the availability of repair parts.
DO NOT return the defective product to the retailer.
Retain the original cash register sales receipt as proof of purchase for warranty work.
Purchasers should contact Porter-Cable directly if they do not receive satisfactory results from the authorized warranty service center.
Porter-Cable Corporation
4825 Highway 45 North
P.O. Box 2468
Jackson, TN 38302-2468
1-888-559-8550
3 — ENG
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and un­derstand. This information relates to protecting YOUR SAFETY and PRE- VENTING EQUIPMENT PROBLEMS. To help you recognize this informa­tion, we use symbols to the right. Please read the manual and pay at­tention to these sections.
IMPORTANT SAFETY INSTRUCTIONS
• SAVE THESE INSTRUCTIONS •
When using this product basic precautions should always be followed
URGENT SAFETY INFORMATION - A HAZ­ARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A HAZARD THAT MIGHT CAUSE SERIOUS INJURY OR LOSS OF LIFE.
including the following:
Information for preventing damage to equipment.
Information that you should pay special attention to.
RISK OF ELECTROCUTION AND FIRE
HAZARD
Attempting to connect generator directly to the electrical system of any building structure.
WHAT COULD HAPPEN
Back feeding electricity through a building’s electrical system to the outside utility feed lines could en­danger repair persons attempting to restore service.
Attempting to connect to the incoming utility service could result in electrocu­tion.
Restoration of electrical service while the generator is connected to the incoming utility could result in a fire or serious damage if an isolator switch is not installed.
Failure to use a double throw transfer switch when connecting to a structure's electrical system can damage appliances and WILL VOID the manufacturer's warranty.
HOW TO PREVENT IT
Never backfeed electricity through a structure's electrical system.
To connect to a structure's electri­cal system in a safe manner, always have a Double-Throw Transfer Switch installed by a qualified electrician and in compli­ance with local ordinances. (When
installing a Double-Throw Trans­fer Switch, a minimum of 10 gauge wiring must be used.)
4 — ENG
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
RISK OF ELECTROCUTION AND FIRE (cont’d)
HAZARD
Operation of generator in rain, wet, icy, or flooded conditions.
Use of worn, damaged, undersized or ungrounded extension cords.
Placing generator on or against highly conductive surface, such as a steel walkway or metal roof.
Water is an excellent conductor of electricity! Water which comes in contact with electrically charged components can transmit electricity to the frame and other surfaces, resulting in electrical shock to anyone contacting them.
Contact with worn or damaged exten­sion cords could result in electrocu­tion.
Use of undersize extension cords could result in overheating of the wires or attached items, resulting in fire.
Use of ungrounded cordsets could prevent operation of circuit breakers and result in electrical shock.
Accidental leakage of electrical current could charge conductive surfaces in contact with the generator.
HOW TO PREVENT ITWHAT COULD HAPPEN
Operate generator in a clean, dry, well ventilated area. Make sure hands are dry before touching unit.
Inspect extension cords before use and replace with new cord if required.
Use proper size (wire gauge) cordset for application see chart in the Assembly section of this manual.
Always use a cordset having a grounding wire with an appropriate grounding plug. DO NOT use an ungrounded plug.
Place generator on low conductivity surface such as a concrete slab.
ALWAYS operate generator a minimum of six feet from any conductive surface.
Improper connection of items to generator.
Operation of unit when damaged, or with guards or panels removed.
Exceeding the load capacity of the generator by attaching too many items, or items with very high load ratings to it could result in overheating of some items or their attachment wiring resulting in fire or electrical shock.
Attempting to use the unit when it has been damaged, or when it is not functioning normally could result in fire or electrocution.
Removal of guarding could expose electrically charged components and result in electrocution.
5 — ENG
Read the load rating chart and instructions in the Wattage Calcula­tion section. Make sure that the summation of electrical loads for all attachments does not exceed the load rating of the generator.
Do not operate generator with mechanical or electrical problem. Have unit repaired by an Autho­rized Service Center.
Do not operate generator with protective guarding removed.
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
RISK OF FIRE
HAZARD
Attempting to fill the fuel tank while the engine is running.
Sparks, fire, hot objects
Improper storage of fuel
Inadequate ventilation for generator
Gasoline and gasoline vapors can become ignited by coming in contact with hot components such as the muffler, engine exhaust gases, or from an electrical spark.
Cigarettes, sparks, fires, or other hot objects can cause gasoline or gasoline vapors to ignite.
Improperly stored fuel could lead to ac­cidental ignition. Fuel improperly secured could get into the hands of children or other unqualified persons.
Materials placed against or near the gen­erator or operating the generator in ar­eas where the temperature exceeds 104° F. ambient (such as storage rooms or ga­rages) can interfere with its proper ven­tilation features causing overheating and possible ignition of the materials or buildings.
HOW TO PREVENT ITWHAT COULD HAPPEN
Turn engine off and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extin­guisher certified to handle gasoline or fuel fires.
Add fuel to tank in well ventilated area. Make sure there are no sources of ignition near the generator.
Store fuel in a OSHA approved con­tainer designed to hold gasoline. Store container in secure location to pre­vent use by others.
Operate generator in a clean, dry, well ventilated area a minimum of four feet from any building, object or wall.
DO NOT OPERATE UNIT IN­DOORS OR IN ANY CONFINED AREA.
Tampering with factory set engine speed settings.
Overfilling the fuel tank – fuel spill­age.
Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could re­sult in overheating of attachments and could cause a fire.
Spilled fuel and its vapors can become ignited from hot surfaces or sparks.
6 — ENG
Never attempt to “speed-up” the en- gine to obtain more performance. Both the output voltage and fre­quency will be thrown out of stan­dard by this practice, endangering attachments and the user.
Use care in filling the tank to avoid spilling fuel. Make sure fuel cap is secured tightly and check engine for fuel leaks before starting engine. Move generator away from refueling area or any spillage before starting engine. Allow for fuel expansion. Keep maximum fuel level 1/2 inch below the tip of the fuel tank. Never refuel with the engine running.
Loading...