Porter Cable CTE300-1, BS600-W-1 Owner’s Manual

Instruction
manual
Generators
T525
CTE300
BSV800
To learn more about Porter-Cable
http://www.porter-cable.com
Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations
PORTER+(HBLE
PROFESSIONAL POWER TOOLS
BS600
IMPORTANT
The Model and SerEal No plate is located on the frame Record these numbers m the spaces below and retain for future reference
Model No
Type
Serial No
D21677-008-0Cooynght © 2000 PORTEP CABLE Corporation
SPECIFICATION
M O DEL CTE300 T525 BS600 BSV800 HORSE POWER 6.0 10 11 14
RATED/SURGE WATTS 3000/3750 5250/6500 6000/7250 8000/10000 VOLTAGE 120 120/240 120/240 120/240 AMPERAGE 25.0A 43.8/21.9A 50A/25A 66.6A/33.3A
PHASE SINGLE SINGLE SINGLE SINGLE
HERTZ 60 Hz 60 Hz 60 Hz 60 Hz
ENGINE SPEED 3600 RPM 3600 RPM 3600 RPM 3600 RPM
MAX. AMBIENT TEMR 104° F 104° F 104° F 104° F
FUEL CAPACITY 4 GALLON 7GALLON 7 GALLON 7 GALLON
RUN TIME @ 50%/100% 11.5/7.2HRS 10.4/7.0HRS 9.1/6.3 HRS 9.6/5.9 HRS
This product is not equipped with a spark arresting muffler. Ifthe product will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required inthe state of
California. It is aviolation of California statutes section 130050 and/or sections 4442 and 4443 of the Califor-
nia Public Resources Code, unless the engine is equipped with a spark arrestor, as defined in section 4442, and maintained in effective working order. Spark attesters are also required on some U. S. Forest service land and may also be legally required under other statutes and ordinances.
This product may contain chemicals known to the state of California to cause cancer, birLh defects, or other reproductive harm. This warning is given incompliance with California Proposition 65, as detectable amounts
of chemicals subject to proposition 65 may be contained inthis product.
2 -- ENG
WARRANTY
PORTER-CABLE CORPORATION warrants to the original purchaser that each new electric generator and service part is free from defects in material and workmanship, and agrees to repair or replace under this warranty any defective product or part as follows from the original date of purchase.
2 YEARS - Limited warranty on electric generator alternators and 1 year limited warranty on all other parts. 90 Days - Service parts
Engine warranties are the responsibility of the engine manufacturer. Warranties of merchandise sold by Porter-Cable
which has been manufactured by and identified as the product of another company are the responsibility of the manufac- turer of that product.
THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER
Products sold damaged or incomplete, sold "as is," sold reconditioned, or used as rental equipment.
Delivery, installation, or normal adjustments explained in the owner's manual.
Damage or liability caused by shipping, improper handling, improper installation, improper maintenance, improper modification, or the use of accessories and/or attachments not specifically recommended by PORTER-CABLE for the
product.
Repairs necessary because of operator abuse or negligence, or the failure to install, operate, maintain, and store the product according to the instructions in the owner's manual.
Damage caused by cold, heat, rain, excessive humidity, corrosive environments and materials, or other contaminants.
Expendable items that become worn during normal use such as fuel filters, air cleaners, spark plugs, and engine oil.
Cosmetic defects that do not interfere with product functionality.
Freight costs from customer to Porter-Cable.
Repair and transportation costs of products or parts determined not to be defective.
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- POSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
WARRANTY SERVICE is available by delivering or shipping the defective product or part to any Porter-Cable authorized warranty service location. To determine the nearest authorized warranty service location, call the toll free number, 1-888-
559-8550, 24 hours a day, 7 days a week. Specific instructions regarding servicing arrangements and scheduling may vary depending on the type and size of the product and the availability of repair parts.
DO NOT return the defective product to the retailer.
Retain the original cash register sales receipt as proof of purchase for warranty work.
Purchasers should contact Porter-Cable directly if they do not receive satisfactory results from the authorized warranty service center.
PORTER+(RBLL
Porter-Cable Corporation
4825 Highway 45 North
RO, Box 2468
Jackson, TN 38302-2468
1_888-559-8550
3 -- ENG
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and un-
derstand. This information relates to protecting YOUR SAFETY and PRE-
VENTING EQUIPMENT PROB- LEMS. TO help you recognize this
information, we use symbols to the right. Please read the manual and pay
attention to these sections.
IMPORTANT SAFETY INSTRUCTIONS
" SAVE THESE INSTRUCTIONS "
When using this product basic precautions should always be followed
I _ DANGER I
URGENT SAFETY INFORMATION - A HAZARD THAT WILL CAUSE SERIOUS INJURY OR
LOSS OF LIFE.
I _WARNING I
IMPORTANT SAFETY INFORMATION - A HAZARD THAT MIGHT CAUSE SERIOUS
INJURY OR LOSS OF LIFE.
including the following:
I _,CAUTION I
Information for preventing damage to equipment.
NOTE I
information that you should pay special attention to.
RISK OF ELECTROCUTION AND FIRE
HAZARD
_.ttempting to connect generator :flrectly to the electrical system of _ny building structure.
WHAT COULD HAPPEN
Back feeding electricity through a
building's electrical system to the outside utility feed lines could en- danger repair persons attempting to
restore service.
Attempting to connect to the incom-
ing utility service could result in electrocution.
Restoration of electrical service while the generator is connected to the
incoming utility could result in a fire or serious damage if an isolator switch is
not installed.
Failure to use a double throw transfer switch when connecting to a
structure's electrical system can damage appliances and WILL VOID the manufacturer's warranty.
HOW TO PREVENT IT
Never backfeed electricity through a structure's electrical system.
To connect to a structure's electri-
cal system in a safe manner, always have a Double-Throw
Transfer Switch installed by a
qualified electrician and in compli- ance with local ordinances. (When installing a Double-Throw
Transfer Switch, a minimum of
10 gauge wiring must be used.)
4 -- ENG
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
RISK OF ELECTROCUTION AND FIRE (cont'd)
HAZARD
Operation of generator in rain, wet, icy, or flooded conditions.
Use of worn, damaged, undersized
or ungrounded extension cords.
Placing generator on or against
highly conductive surface, such as a steel walkway or metal roof.
WHAT COULD HAPPEN
Water is an excellent conductor of electricity! Water which comes in
contact with electrically charged components can transmit electricity to the frame and other surfaces, resulting in electrical shock to anyone contact- ing them.
Contact with worn or damaged extension cords could result in
electrocution.
Use of undersize extension cords could result in overheating of the
wires or attached items, resulting in fire.
Use of ungrounded cordsets could
prevent operation of circuit breakers
and result in electrical shock.
Accidental leakage of electrical current could charge conductive surfaces in contact with the generator.
HOW TO PREVENT IT
Operate generator in a clean, dry, well ventilated area. Make sure
hands are dry before touching unit.
Inspect extension cords before use and replace with new cord if required.
Use proper size (wire gauge) cordset for application see chart in the Assembly section of this
manual.
Always use a cordset having a
grounding wire with an appropriate grounding plug. DO NOT use an ungrounded plug.
Place generator on low conductiv- ity surface such as a concrete
slab.
Improper connection of items to
generator.
Operation of unit when damaged, or with guards or panels removed.
Exceeding the load capacity of the generator by attaching too many items, or items with very high load ratings to it could result in overheating
of some items or their attachment wiring resulting in fire or electrical
shock.
Attempting to use the unit when it has been damaged, or when it is not functioning normally could result in
fire or electrocution.
Removal of guarding could expose electrically charged components and
result in electrocution.
5 -- ENG
ALWAYS operate generator a
minimum of six feet from any conductive surface.
Read the load rating chart and instructions in the Wattage Calcu-
lation section. Make sure that the summation of electrical loads for
all attachments does not exceed the load rating of the generator.
Do not operate generator with mechanical or electrical problem. Have unit repaired by an Autho-
rized Service Center.
Do not operate generator with protective guarding removed.
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
RISK OF FIRE
HAZARD
Attempting to fill the fuel tank while the engine is running.
Sparks, fire, hot objects
Improper storage of fuel
Inadequate ventilation for generator
WHAT COULD HAPPEN
Gasoline and gasoline vapors can become ignited by coming in contact
with hot components such as the muffler, engine exhaust gases, or from
an electrical spark.
Cigarettes, sparks, fires, or other hot objects can cause gasoline or gaso-
line vapors to ignite.
Improperly stored fuel could lead to ac- cidental ignition. Fuel improperly se-
cured could get into the hands of chil- dren or other unqualified persons.
Materials placed against or near the generator or operating the generator in
areas where the temperature exceeds 104 ° R ambient (such as storage rooms
or garages) can interfere with its proper ventilation features causing overheat-
ing and possible ignition of the materi- als or buildings.
HOW TO PREVENT IT
Turn engine off and allow it to cool
before adding fuel to the tank. Equip area of operation with a fire extin-
guisher certified to handle gasoline or fuel fires.
Add fuel to tank in well ventilated
area. Make sure there are no sources of ignition near the genera-
tor.
Store fuel in a OSHA approved con-
tainer designed to hold gasoline.
Store container in secure location to prevent use by others.
Operate generator in a clean, dry, well ventilated area a minimum of
four feet from any building, object
or wall. DO NOT OPERATE UNIT
INDOORS OR IN ANY CONFINED
AREA.
Tampering with factory set engine speed settings.
Overfilling the fuel tank - fuel spill- age.
Engine speed has been factory set to provide safe operation. Tampering with
the engine speed adjustment could re- sult in overheating of attachments and
could cause a fire.
Spilled fuel and its vapors can become
ignited from hot surfaces or sparks.
6 -- ENG
Never attempt to "speed-up" the engine to obtain more performance. Both the output voltage and fre- quency will be thrown out of stan- dard by this practice, endangering
attachments and the user.
Use care in filling the tank to avoid spilling fuel. Make sure fuel cap is secured tightly and check engine for fuel leaks before starting engine. Move generator away from refueling area or any spillage before starting engine. Allow for fuel expansion. Keep maximum fuel level inch below the tip of
the fuel tank. Never refuel with the engine running.