Porter-Cable A16759 User Manual

Instruction
manual
Model
C3551
ESPAÑOL: PÁGINA 27 FRANÇAIS: PAGE 53
Direct Drive Oil Lube Portable Air Compressor
To learn more about Porter-Cable
visit our website at:
http://www.porter-cable.com
®
Copyright © 2006 Porter-Cable
IMPORTANT
Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations.
The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference.
Model No. Type Serial No.
Part No. A16759-062-0
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
Indicates an
imminently hazardous situation which, if not avoided, will result in death or serious injury.
which, if not avoided, may result in minor
or moderate injury.
Indicates a potentially hazardous situation
Indicates a potentially
hazardous situation which, if not avoided, could result in
death or serious injury.
indicates a potentially hazardous situation which, if not avoided, may result in
property damage.
Used without the safety alert symbol
IMPORTANT SAFETY INSTRUCTIONS
Some dust created by power sanding, sawing, grinding,
chemicals known (to the State of California) to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
lead from lead-based paints
crystalline silica from bricks and cement and other masonry products
arsenic and chromium from chemically-treated lumber Your risk from these exposures varies, depending on how often you do
this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, al ways wear MSHA/NIOSH approved, properly fit ting face mask or res pi ra tor when us ing such tools.
When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury.
drilling, and other construction activities contains
A16759
2- ENG
IMPORTANT SAFETY INSTRUCTIONS
Save these instructions
Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
HAZARD
WARNING: Risk of explosion or fire
What Could Happen
It is normal for electrical contacts within the motor and pressure switch to spark.
If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.
Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.
Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.
How To Prevent It
Always operate the compressor in a well ventilated area free of combustible
materials, gasoline, or solvent vapors.
If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose
may be required.
Store flammable materials in a secure location away from compressor.
Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that
would restrict the flow of fresh air to the ventilation openings.
Operate compressor in a clean, dry well ventilated area. Do not operate unit
indoors or in any confined area. Always remain in attendance with the
product when it is operating.
Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.
3 - ENG
A16759
HAZARD
WARNING: Risk of Bursting
Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury.
What Could Happen
Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
Modifications or attempted repairs to the tank.
Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure.
Excessive vibration can weaken the air tank and cause rupture or explosion
ATTACHMENTS & ACCESSORIES:
Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires, and other inflatables can cause them to explode or fly apart,
and could result in serious injury.
TIRES:
Over inflation of tires could result in serous injury and property damage.
Drain tank daily or after each use.
If tank develops a leak, replace it immediately with a new tank or replace the entire compressor.
Never drill into, weld, or make any modifications to the tank or its
attachments.
The tank is designed to withstand specific operating pressures. Never make
adjustments or parts substitutions to alter the factory set operating pressures.
For essential control of air pressure,
you must install a pressure regulator and pressure gauge to the air outlet (if not equipped) of your compressor.
Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use compressor
to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
Use a tire pressure gauge to check the tires pressure before each use and while inflating tires; see the tire sidewall for the correct tire pressure.
NOTE: Air tanks, compressors and similar equipment used to inflate tires can fill small tires similar to these very rapidly. Adjust pressure regulator on air supply to no more than the rating of the tire pressure. Add air in small increments and frequently use the tire gauge to prevent over inflation.
How To Prevent It
A16759
4- ENG
HAZARD
WARNING: Risk from Flying Objects
What Could Happen
The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or
personal injury.
HAZARD
WARNING: Risk of Electrical Shock
What Could Happen
Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock.
Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
How To Prevent It
Always wear ANSI Z87.1 approved safety glasses with side shields when
using the compressor.
Never point any nozzle or sprayer toward any part of the body or at other people or animals.
Always turn the compressor off and bleed pressure from the air hose and
tank before attempting maintenance, attaching tools or accessories.
How To Prevent It
Never operate the compressor outdoors when it is raining or in wet conditions.
Never operate compressor with protective covers removed or damaged.
Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electrical codes.
Electrical Grounding: Failure to provide
adequate grounding to this product could result in serious injury or death from electrocution.
See grounding instructions.
Make certain that the electrical circuit
to which the compressor is connected
provides proper electrical grounding, correct voltage and adequate fuse protection.
5 - ENG
A16759
HAZARD
WARNING: Risk to Breathing
What Could Happen
The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon
monoxide, toxic vapors, or solid particles from the tank. Breathing these contaminants can cause serious injury or death.
Sprayed materials such as paint, paint
solvents, paint remover, insecticides, weed killers, may contain harmful
vapors and poisons.
HAZARD
WARNING: Risk of Burns
What Could Happen
Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
How To Prevent It
Air obtained directly from the compressor should never be used to supply air for human consumption. In order to use air
produced by this compressor for breathing, suitable filters and in-line safety equipment must be properly installed. In-line filters and safety equipment used in conjunction with the compressor
must be capable of treating air to all applicable local and federal codes prior to human consumption.
Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Use a NIOSH/ MSHA approved respirator designed for use with
your specific application.
How To Prevent It
Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
HAZARD
WARNING: Risk from Moving Parts
What Could Happen
Moving parts such as the pulley, flywheel,
and belt can cause serious injury if they come into contact with you or your clothing.
Attempting to operate compressor with damaged or missing parts or attempting
to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious
injury.
A16759
How To Prevent It
Never operate the compressor with guards or covers which are damaged or removed.
Any repairs required on this product should be performed by authorized service center personnel.
6- ENG
HAZARD
WARNING: Risk of Falling
What Could Happen
A portable compressor can fall from a table, workbench, or roof causing
damage to the compressor and could result in serious injury or death to the operator.
Always operate compressor in a stable secure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use additional air hose to reach high locations.
How To Prevent It
HAZARD
WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor
(Fire, Inhalation, Damage to Vehicle Surfaces)
What Could Happen
Oil can leak or spill and could result
in fire or breathing hazard; serious injury or death can result. oil leaks will damage carpet, paint or other surfaces in vehicles or trailers.
Always place COMPRESSOR on a protective mat when transporting to protect against damage to vehicle from leaks. Remove COMPRESSOR from vehicle immediately upon arrival at your destination.
How To Prevent It
HAZARD
WARNING: Risk of Unsafe Operation
What Could Happen
How To Prevent It
Unsafe op er a tion of your air compressor could lead to se ri ous in ju ry or death to you or others.
Review and understand all instructions and warnings in this manual.
Be come fa mil iar with the op er a tion and con trols of the air compressor.
Keep operating area clear of all persons,
pets, and obstacles. Keep chil dren away from the air
compressor at all times.
Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times.
Never defeat the safety fea tures of this
prod uct.
Equip area of operation with a fire extinguisher.
Do not op er ate machine with missing, broken, or un au tho rized parts.
SAVE THESE INSTRUCTIONS
7 - ENG
A16759
GLOSSARY
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL,
CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety. Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
DUTY CYCLE
This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.
SPECIFICATIONS
Model No. C3551
Running Horsepower 1.3 Bore 2.363" Stroke 0.890 * Voltage-Single Phase 120 * * Minimum Branch Circuit Requirement 15 amps * Fuse Type Time Delay Air Tank Capacity (Gallon) 4.5 ASME Approximate Cut-in Pressure 120 PSIG Approximate Cut-out Pressure 150PSIG SCFM @ 40 PSIG 5.7 SCFM @ 90 PSIG 4.4
ACCESSORIES
Accessories for this unit are available at the store the unit was purchased.
A16759
8- ENG
ASSEMBLY
To Add Oil To Pump
DO NOT ATTEMPT TO OPERATE THIS AIR COMPRESSOR
WITHOUT FIRST ADDING OIL TO THE CRANKCASE. Serious damage can result from even limited operation unless filled with oil and broken in correctly. Make sure to closely follow initial start-up procedures.
COMPRESSORS ARE SHIPPED WITHOUT OIL. A small
amount of oil may be present in the pump upon receipt of the air compressor. This is due to plant testing and does not mean the pump contains oil.
Multi-Viscosity motor oils, like 10W30, should not be
used in an air compressor. They leave carbon deposits on critical components, thus reducing performance and compressor life. Use air compressor oil only. NOTE: Use an oil specifically formulated for use in an air compressor, such as
Porter-Cable PAS1 air compressor oil. Oil may be found at the store where the air compressor was purchased.
1. Place unit on a level surface.
Drain tank to release air pressure before removing the
dipstick.
Make sure air vent (B)
in dipstick is free from debris. If air vent is blocked pressure can build in crankcase causing damage to air compressor and possible personal injury.
2. Remove dipstick (A) and slowly fill
crankcase with oil. Crankcase capacity is 6 fluid ounces (177.4 ml). Oil level should be at the + (full) mark on the dipstick.
NOTE: If the oil is added too quickly, it will overflow and appear to be full.
3. Replace dipstick.
+ full
- add
B
A
+
-
9 - ENG
A16759
INSTALLATION
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
Locate the air compressor in a clean, dry, and well ventilated area.
The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
The air filter must be kept clear of obstructions which could reduce air flow to the air compressor.
The air compressor requires fresh air flow for proper cooling. DO NOT ALLOW THE COMPRESSOR TO GET WET.
GROUNDING INSTRUCTIONS
RISK OF ELECTRICAL SHOCK. In the event of a short
circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).
1. The cord set and plug with this unit contains a grounding pin. This plug
MUST be used with a grounded outlet.
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.
2. Make sure the outlet being used
has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.
3. Inspect the plug and cord before each
use. Do not use if there are signs of damage.
4. If these grounding instructions are
not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
IMPROPER GROUNDING CAN RESULT IN ELECTRICAL
SHOCK. Do not modify the plug provided. If it does not fit the available outlet, a
correct outlet should be installed by a qualified electrician. Repairs to the cord set or plug MUST be made by a qualified electrician.
Plug
Grounded Outlets
Grounding Pin
A16759
10- ENG
Extension Cords
Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating.
Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot
receptacle that will accept the plug on the product
• in good condition
no longer than 50 feet
12 gauge (AWG) or larger. (Wire size increases as gauge number
decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)
Voltage and Circuit Protection
Refer to the specification chart for the voltage and minimum branch circuit requirements.
Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.
1. Voltage supply through branch circuit is 15 amps.
2. Circuit is not used to supply any other electrical needs (lights, appliances,
etc.).
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay
fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.
11 - ENG
A16759
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.
Description of Operation
Become familiar with these controls before operating the unit. On/Auto/Off Switch (A): Turn this
switch "ON/AUTO" to provide automatic power to the pressure switch and "OFF" to remove power at the end of each use.
Pressure Switch (B): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.
Safety Valve (C): If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).
Outlet Pressure Gauge(D): The outlet pressure gauge
H
indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.
Tank Pressure Gauge(E): The tank pressure gauge indicates the reserve air pressure in the tank.
Regulator (F): Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.
Universal Quick-Connect Body (G): The universal quick-connect body accepts the three most popular styles of quick-connect plugs- Industrial, automotive (Tru-flate), and ARO. One hand push-to-connect operation makes connections simple and easy. The two quick connect bodies allow the use of two tools at the same time.
Remote Console (H): Permits remote air regulation and control closer to work area, includes two high-flow industrial/automotive style compatible quick­connects, outlet pressure gauge, and a high-flow regulator.
A
G
F
B
C
E
D
A16759
12- ENG
Drain Valve (I): The drain valve is located at the base of the air tank and is
I
used to drain condensation at the end of each use.
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air over the pump head, cylinder sleeve, and crankcase. You know the cooling system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Dipstick (J): Indicates the amount of oil in the pump, the + mark indicates full and the - mark indicates oil needs to be added. See Oil paragraphs in the Maintenance section for instructions.
Motor Thermal Overload Protector (not shown): The motor has an automatic reset thermal overload protector.
J
If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.
Air Intake Filter (K): This filter is designed to clean air coming into the pump. This filter must always be clean
L
and ventilation openings free from obstructions. See "Maintenance".
Check Valve (L): When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air
K
compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.
Pressure Release Valve (M): The pressure release valve located on the side of the pressure switch, is
M
designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches "cut-out" pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches "cut-out" pressure.
13 - ENG
A16759
How to Use Your Unit
How to Stop:
1. Set the On/Auto/Off lever to "OFF".
Before Starting
Break-in Procedure
Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Auto/Off lever is in the "OFF" position.
2. Check oil level in pump. See "Oil" paragraph in the "Maintenance" section
for instructions.
3.
Plug the power cord into the correct branch circuit receptacle. Voltage and Circuit Protection paragraph in the Installation section of this manual.)
4. Open the drain valve fully (counter-clockwise) to permit air to escape and
prevent air pressure build up in the air tank during the break-in period.
5. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will
start.
6. Run the compressor for 20 minutes. Make sure the drain valve is open and
there is minimal air pressure build-up in tank.
7. After 20 minutes,
to "cut-out" pressure and the motor will stop.
The compressor is now ready for use.
the tire sidewall for the correct tire pressure. NOTE: Air tanks, compressors and similar equipment used to infl ate tires can fi ll
small tires similar to these very rapidly. Adjust pressure regulator on air supply to no more than the rating of the tire pressure. Add air in small increments and frequently use the tire gauge to prevent over infl ation.
close the drain valve (clockwise). The air receiver will fill
Risk of bursting. tires pressure before each use and while infl ating tires; see
Use a tire pressure gauge to check the
(Refer to
Before Each Start-Up:
1. Place On/Auto/Off lever to "OFF".
2. Pull regulator knob out, turn counter-clockwise until it stops. Push knob in
to lock in place.
3. Attach hose and accessories. NOTE: The hose or accessory will require
a quick connect plug. To use remote console, see "How to Use Remote Console" paragraph in this section.
Too much air pressure causes a hazardous risk of
bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
A16759
14- ENG
How to Start:
1. Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2. Pull the regulator knob out and turn clockwise to increase pressure.
When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.
NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.
How to Use Remote Console:
When needed the remote console allows remote air regulation and control closer to the work area.
Reduce air pressure in tank to 60 psi maximum before connecting hose to tank quick-connect coupler.
1. Turn knobs counter clockwise to loosen knobs securing control panel.
2. Slide console up and away from frame, disconnect air hose from quick connect (a),
and remove console.
removing or connecting portable control panel and when
a
3. Connect air hose (sold separately) to quick connect plug (b) and quick connect
(a). The console can then be brought closer to the work site to rest on the console brackets (d) or be temporarily mounted using the mounting hole (c).
c
a
b
d
Can cause serious injury or death. Tank may contain
150 PSI of air pressure. Never connect accessories to unregulated air. Never operate tools or accessories above marked maximum pressure.
15 - ENG
A16759
How to transport unit
The unit has a handle (a) for carrying and a handle (b) for pulling.
1. Grasp carrying handle (a) to lift unit.
a
b
2. Slide handle (b) out until it locks into place.
a
b
3. Pull unit as shown, do not push unit. NOTE: When transporting do not lift
the unit to the point where it would tip over backwards.
IMPORTANT: Only use pulling handle to pull unit, use the carrying handle to lift and carry unit.
A16759
16- ENG
MAINTENANCE
Customer Responsibilities
Before each use
Check Safety Valve Drain Tank
Oil Leaks Check Oil
Daily or after each use
Every 8 hours
Every 40 hours
Change Oil
1
Air Filter
1- more frequent in dusty or humid conditions
Unit cycles automatically when power is on. When
performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.
NOTE: See "Operation" section for the location of controls.
Every 160 hours
Every 100 hours
To Check Safety Valve
If the safety valve does not work properly, over pressurization may occur, causing air tank rupture or an
explosion.
1. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
To Drain Tank
1. Set the On/Auto/Off lever to "OFF".
2. Pull the regulator knob out and turn counter clockwise to set the outlet pressure to zero.
3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.
17 - ENG
A16759
5. Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. NOTE: Tilt tank to drain tank completely.
Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air
tank rupture.
6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.
NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.
Oil
Drain tank to release air pressure before removing the dipstick or oil drain plug.
Compressor head and cylinder sleeve are very hot. Do not touch.
Checking
1. Set the On/Auto/Off lever to "OFF".
2. Remove dipstick (A) and check oil on dipstick for visual signs of contaminants (water, dirt, etc).
Make sure air vent (C) in dipstick is free from
C
debris. If air vent is blocked pressure can build in crankcase causing damage
A
to air compressor and possible personal injury.
3. Wipe oil from dipstick.
4. Replace dipstick and allow oil to collect on dipstick.
5. Remove dipstick and check oil level
+
on dipstick, + mark indicates full and the - mark indicates add oil. If oil level is below - mark, slowly add oil
B
(+)Full (-)Add
-
until it reaches the + (full) mark on the dipstick.
NOTE: Use an oil specifically formulated for use in an air compressor, such as Porter-Cable PAS1 air compressor oil. Oil may be found at the store where the air compressor was purchased.
6. Replace dipstick (A).
Changing
1. Set the On/Auto/Off lever to "OFF".
2. Remove the dipstick (A).
3. Remove the oil drain plug (B) and drain oil into a suitable container.
A16759
18- ENG
Air Filter - Inspection and Replacement
Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor
to cool prior to servicing.
A dirty air filter will not allow the compressor to operate at full capacity. Keep the air filter clean at all times.
1. Remove the air filter cover.
2. Remove the air filter from filter cover. IMPORTANT: Do not operate the compressor with the air filter removed.
3. Place new air filter into filter cover. Refer to the "Repair Parts" for the correct part number.
4. Replace air filter cover and lock into place.
Motor
The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.
If the overload protector shuts the motor off frequently, check for a possible voltage problem. Low voltage can also be suspected when:
1. The motor does not get up to full power or speed.
2. Fuses blow out when starting the motor; lights dim and remain dim when motor is started and is running.
19 - ENG
A16759
SERVICE AND ADJUSTMENTS
Unit cycles automatically when power is on. When doing
compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.
Unplug or disconnect electrical supply to the air compressor.
Bleed tank of pressure.
Allow the air compressor to cool.
To Replace or Clean Check Valve
1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.
2. Unplug outfit.
NOTE: If needed the top panel may be removed to make parts accessible.
3. Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve.
4. Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve.
5. Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the orientation for reassembly.
6. Unscrew elbow fitting from the check valve (turn counterclockwise) using an adjustable wrench. Note the orientation of the elbow fitting for reassembly.
7. Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position. If not, the check valve needs to be cleaned or replaced.
8. Clean or replace the check valve. A solvent, such as paint or varnish remover can be used to clean the check valve.
9. Apply sealant to the check valve threads. Reinstall the check valve and elbow fitting (turn clockwise).
10. Replace the pressure release tube. Tighten nut.
11. Replace the outlet tube and tighten nut.
12. Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.
A16759
Maintenance, you may be exposed to voltage sources,
Before servicing:
Pressure Relief Tube
In open position nothing is visible.
20- ENG
Elbow Fitting
Check Valve
Screwdriver
Nuts
Outlet Tube
In closed position disc is visible.
STORAGE
Before you store the air compressor, make sure you do the following:
1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.
2. Set the On/Auto/Off lever to "OFF".
3. Turn the regulator counterclockwise and set the outlet pressure to zero.
4. Remove the air tool or accessory.
5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.
6. Drain water from air tank by opening drain valve on bottom of tank.
Water will condense in the air tank. If not drained, water
tank rupture.
7. After the water has been drained, close the drain or drain valve.
NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.
8. Wrap electrical cord onto the cord wrap as shown.
9. Protect the air hose from damage (such as being stepped on or run over).
10. Push pulling handle into place for storage.
11. Store the air compressor in a clean and dry location.
IMPORTANT: Only use pulling handle to pull unit, use the carrying handle to lift and carry unit.
will corrode and weaken the air tank causing a risk of air
21 - ENG
A16759
TROUBLESHOOTING
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure.
PROBLEM
Excessive tank pressure
- safety valve pops off.
Air leaks at fittings.
Air leaks at or inside check valve
CAUSE
Pressure switch does not shut off motor when compressor reaches "cut­out" pressure.
Pressure switch "cut-out" too high.
Tube fittings are not tight enough.
Check valve seat damaged.
CORRECTION
Move On/Auto/Off lever to the "OFF" position, if the outfit does not shut off contact a Trained Service Technician. Contact a Trained Service Technician.
Tighten fittings where air can be heard escaping. Check fittings with soapy water solution. DO NOT OVERTIGHTEN.
A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off. Replace check valve. Refer the "To Replace or Clean Check Valve" in the "Service and Adjustment" section.
Air leaks at pressure switch release valve. (if equipped)
Air leaks in air tank or at air tank welds.
Air leaks between head and valve plate.
A16759
Defective pressure switch release valve.
Defective air tank.
Leaking seal.
22- ENG
Contact a Trained Service Technician.
Air tank must be replaced.
Do not repair
the leak. Do not drill into,
weld or otherwise modify air tank or it will weaken. The tank can rupture or explode.
Contact a Trained Service Technician.
PROBLEM
Pressure reading on the regulated pressure gauge (if equipped) drops when an accessory is used.
Air leak from safety valve.
CAUSE
It is normal for "some" pressure drop to occur.
Possible defect in safety valve.
CORRECTION
If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator as instructed in the Operation section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used).
Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced.
Compressor is not supplying enough air to operate accessories.
Restricted air intake
Regulator knob has continuous air leak.
Prolonged excessive use
Decrease amount of air usage.
of air. Compressor is not large enough for air requirement.
Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor.
Hole in hose. Check valve restricted. Air leaks. Restricted air intake filter
Check and replace if required. Remove and clean, or replace. Tighten fittings. Clean or replace air intake
filter. Do not operate the air compressor with the filter removed. Refer to the "Air Filter" paragraph in the "Maintenance" section.
Dirty air filter.
Clean or replace. See "Air Filter" paragraph in the "Maintenance" section.
Damaged regulator Have checked by a Trained
Service Technician.
Regulator will not shut off air outlet.
Damaged regulator
23 - ENG
Have checked by a Trained Service Technician.
A16759
PROBLEM
Motor will not run.
CAUSE
Motor overload protection switch has tripped
CORRECTION
Let motor cool off and overload switch will automatically reset.
Tank pressure exceeds pressure switch "cut-in" pressure.
Check valve stuck open. Loose electrical
connections.
Possible defective motor or starting capacitor.
Paint spray on internal motor parts.
Pressure release valve on pressure switch has not unloaded head pressure.
Fuse blown, circuit breaker tripped.
Motor will start automatically when tank pressure drops below "cut-in" pressure of pressure switch.
Remove and clean, or replace.
Check wiring connection inside pressure switch and terminal box area.
Have checked by a Trained Service Technician.
Have checked by a Trained Service Technician. Do not operate the compressor in the paint spray area. See flammable vapor warning.
Bleed the line by pushing the lever on the pressure switch to the "OFF" position; if the valve does not open, replace switch.
1. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit.
A16759
24- ENG