Portal 724 MNBWS100 User Manual

1 /
BLUETOOTH BODY SCALE
Model: MN-BWS100
Instruction Manual
Version 1.0
please read through this instruction manual prior to using this scale.
2 /
◆Place your scale on a carpet or on a solid level surface, such as tile, wood, or laminate flooring.
◆Do not place your scale on a soft, wet or slippery floor.
◆Your scale contains delicate, high-precision parts. Avoid extrenes in temperature, humidity, direct sunlight, shock, moisture and dust.
◆Do not step on your scale with your feet wet. Be sure that your feet are dry to prevrnt slipping or serious injury.
◆Step on the center portion of your scale gently.
◆Do not step on the display window.
Indications for Use
This scale is designed for personal use.
Appearance introduction
Front
3 /
Back
Insert each battery with it´s positive (+) and negative (-) terminals properly aligned
Tempered glass
“ UNIT ”
Battery
Carpet feet
Handle
Bottom shell
Installing (or Replacing) Batteries
Caution
4 /
with the corresponding symbols in the battery compartment.
Improper installation of the batteries may cause battery leakage.
Replace the cover by sliding it into the compartment and gently pressing it into place.
Step on the scale gently, placing both feet on the center portion of the scale.
Replace all four batteries with new ones, when the “Lo” symbol is displayed.
Do not mix new and used batteries. It may cause damage to the scale or shorten battery
life.
The battery life is dependent upon the environmental temperature, battery type and
usage.
Remove the batteries from the battery compartment, when the scale is not to be used for
a long time. They may leak and damage the scale.
Steps for Installing (or Replacing) Batteries
Remove the battery compartment cover on the underside of the scale by gently pushing
the hook in the direction indicated by the arrow and lifting the cover backward.
If necessary, remove the old batteries in the order suggested below. Install four new
batteries with the positive (+) and negative (-) terminals properly aligned with the corresponding symbols in the battery compartment.
Measuring Your Weight
Place the scale on a solid level surface.
Tap the scale gently with one foot to turn it on and calibrate it to display “0.0 lb”. The scale must becalibrated to ensure accurate measurement.
5 /
“- - - -” Four ashing dashes will display until the measurement is taken.
Your weight is displayed.
Once the reading is taken you will hear 3 loud beeps.
Simultaneously, your weight will be displayed, all at once, in 3flashing instances.
Step o the scale.
The scale will automatically turn o after displaying your weight even if you are still
standing on it.
Display
Digital LED
Resolution
0.1 kg / 0.2 lb
Unit
Kg, lb, st
Boot Mode
Gravity boot, power on, boot button
Please stand still during the measurement.
Then your weight will be displayed for 5 seconds on the LCD.
Specifications
6 /
Measurement Range
11.2-551 lb / 5.1-250 kg
Accuracy
50kg±3D,100kg±4D,150kg±5D,200kg±6D,250kg±7D
Weigh the Weight
11.2 lb / 5.1 kg
Zero Range
0.22 lb / 100 g
Overloading Tips
Reach to Max+11 1b/Max+5kg, it will be displayed “EEEE”
Turn off Mode
Automatic Turn off
Low Voltage Detection
Battery Voltage is 4±0.2 V, it will turn off after display“Lo” for
1 second.
Power source
Four type “ AA ” batteries ( R6P or LR6, 1.5 Volt ×4 )
Volume
≥70dB(Test Distance:30cm)
wireless communication
Bluetooth 4.0
Bluetooth Transmission
Distance
10 Meters(Unobstructed Transmission Distance)
Equipment Requirement
Android 4.4 or above operating system and a blue version of 4.0 mobile
terminal equipment;
iOS7.0 or above operating system and a blue version of 4.0 mobile
terminal equipment.
Size
≈ L380 × W320 ×H41 mm
System function description
◆the scale has an automatic power-on and off function.
Operation Environment
Operation temperature: +10 - +40℃
◆Automatic turn off:
●When the battery is installed, the LED will turn off automatically after about 2 seconds.
●The battery voltage drops to the preset warning value, and it will turn off automatically after
the LED display “Lo” about 1 second.
●Steady display of weight about 6 seconds after the automatic turn off.
◆Unit defaults to “lb”, short press the machine “UNIT”button in the “lb”, “st”, “kg” between the switch back and forth, each time to play a “beep” warning sound.
◆It can automatically weighing when people stand on the scale in the turnoff state.
◆When the weight is not locked, “---” is displayed on the LED and flashed twice.
◆After the weight is locked, the value will flash 3 times and a “beep” beep will be
played once every flashing.
◆During the use of the Bluetooth is not connected to the “ ” flashing state, it will be
in a steady state after connection successfully.
Operating and Storage Environments
7 /
Humidity: ≤ 90% RH
Storage Environment
Temperature: -10 - +50℃ Humidity: ≤ 90% RH
Compliance with European Directives
★Note: For Indoor use only. The displayed value may be adversely a ected under extreme
electromagnetic influences.
Compliance with FCC Rules
The scale complies with part 15 of the FCC rules and contains the FCC ID: XXXXXXXXXXXX.
Clean the scale with a soft dry cloth or a cloth moistened with water and a mild
detergent. Never use alcohol or other harsh chemicals to clean the scale.
Remove the batteries from the battery compartment, when the scale is not going to be
used for a long time.
Cause/Problem
Corrective Action
Nothing is displayed by stepping on the scale.
Check the battery installation. Replace with rour new batteries.
There is a large difference between estimated weight and data measurement.
Remove any foreign objects that might be touching the bottom of the scale.
The scale complies with the statutory Electromagnetic Compatibility (EMC) Directive 2014/30/EU.
Maintaining the Scale
How the Wireless Connection Works
At the end of the measurement, your weight will be sent automatically to your tablet. You do not need to do anything.
Before Requesting Service
If you cannot locate and fix the problem, contact your supplier.
8 /
Component List
BLUETOOTH BODY SCALE Instruction Manual “ AA ” batteries x4
x1
x1
Manufacturer
Manufacturer: Portal 724, LLC
ADD: 275 Hartz Way, Suite 105, Secaucus, NJ 07094 U.S.A
FCC STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1.This device may not cause harmful interference, and
2.This device must accept any interference received, including interference that may
cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Loading...