SPECIFICATION
INPUT VOLTAGE RANGE : DC 10~15V (12V) // DC 20~30V (24V) INPUT FULL LOAD CURRENT : 110A (12V) // 55A (24V) STANDBY INPUT CURRENT : <1.3A (12V) // <1A (24V) EuP MODE INPUT CURRENT : <0.15A (12V) // <0.15A (24V) EuP MODE AC OUTPUT : DETECTING AC OUTPUT EVERY 4 SECOND OUTPUT VOLTAGE (AC) : 220V~240V OUTPUT WAVEFORM : PURE SINEWAVE OUTPUT FREQUENCY : 50Hz or 60Hz CONTINUE OUTPUT POWER : 1000W OUTPUT POWER : 1200W (10mini) PEAK OUTPUT POWER : 2000W EFFICIENCY : 85% BATTERY LOW ALARM : 10.5V
± 0.5V (12V) // 21 ± 1V (24V)
BATTERY LOW SHUTDOWN : 10V
± 0.5V (12V) // 20 ± 1V (24V)
THERMAL PROTECT : 60
± 5(MICROCONTROLLER )
AUTO-OPERATION FAN (TEMPERATURE OR LOAD) OVERLOAD PROTECT : YES (MICROCONTROLLER ) OUTPUT SHORT PROTECT : YES ( MICROCONTROLLER ) BATTERY EX. 12V / 24V PROTECT : YES ( MICROCONTROLLER ) FAN COOLING : CONTROL BY TEMPERATURE BATTERY POLARITY PROTECT : YES (BY FUSE ) FUSE : 25A*6PC (12V) // 15A*6PC (24V) DIMENTION ( L*W*H) mm : 360*195*80 WEIGHT : 4.1kg
TROUBLESHOOTING
IF THE INVERTER DOES NOT APPEAR TO BE FUNCTIONING PROPERLY, THERE ARE SEVERAL REASONS WHY THE INVERTER MAY NOT BE RESPONDING.
1) POOR CONTACT *CLEAN CONTACT PARTS THOROUGHLY.
2) RECEPTACVLE HAS NO POWER *CHECK FUSE, REPLACE DAMAGED FUSE. *CHECK RECEPTACLE WIRING. REPAIR IF NECESSARY
3) FUSE IS BLOWN *THE FUSE IS LOCATED INSIDE THE DC PLUG. REPLACE FUSE WITH A FUSE OF EQUIVALENT VALUE.
4) OVERLOAD CAUSED AC OUTPUT REDUCE *REDUCE THE WATTAGE OF YOUR LOAD TO LOWER THAN 1000 WATTS.
5) THERMAL CAUSED AC OUTPUT REDUCE *UNDER HEAVY LOADS FOR EXTENDED PERIODS OF TIME. THE AC INVERTER WILL REDUCE OUTPUT TO PREVENT DAMAGE TO EXCESS HEAT. IF THIS HAPPENS, PLASE PROCEED AS BELOW : (A) SWITCH OFF THE POWER SWITCH OF THIS INVERTER. (B) DECREASE LOAD OF THIS MACHINE I. E. DISCONNECT SOME OF THE
APPLIANCES OR WAIT UNTIL THIS INVERTER BECOME COOL.
(C) SWITCH ON THE POWER SWITCH OF THIS INVERTER.
6) LOW-BATTERY SHUTDOWN *RECHARGE YOUR BATTERY AND RESUME OPERATION.
CAUTION
ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS: (A) WELL VENTILATED (B) NOT EXPOSED TO DIRECT SUNLIGHT
OR HEAT SOURCE (C) OUT OF REACH FROM CHILDREN (D) AWAY FROM WATER/MOISTURE,
OIL OR GREASE (E) AWAY FROM ANY FLAMMABLE SUBSTANCE
FAN
TERMINA
L
(BLACK)
TERMINAL
(RED)
WARNING: DO NOT REVERSE INPUT
LOAD
BATTERY
0%
50%
100%
10
11
12
13
14
15
20
22
24
26
28
30
12V
24V
POWER SWITCH
ON
OFF
REMOTE CONTROL
AC OUTPUT
AC
OUTLET
OVER LOAD
OVER TEMP
NORMAL
LOAD
BATTERY
0%
50%
100%
10
11
12
13
14
15
20
22
24
26
28
3
CAUTION : DO NOT REVERSE INPUT. USE RED BATTERY CORD TO CONNECT (+) OF A DC BATTERY TO (+) TERMINAL. AND THEN, USE BLACK BATTERY CORD TO CONNECT (-) BATTERY TO (-) TERMINAL.
BATTERY
BLACK
RED
WARNING: DO NOT REVERSE INPUT
FAN
Optional accessory : Remote control
REMOTE CONTROL OPERATION : WHEN CONNECTED TO ANY APPLIANCE, BE SURE TO TURN ON INVERTER FIRST. AND THEN, CONNECT WITH THE REMOTE CONTROL WELL AND TURN ON THE SWITCH OF REMOTE CONTROL.
TURN ON/OFF
SECONDLY
TURN ON FIRSTLY
REMOTE CONTROL
POWER
ON/OFF
ON
OFF
REMOTE CONTROL
AC OUTPUT
AC
OUTLET
OVER LOAD
OVER TEMP
NORMAL
LOAD
BATTERY
0%
50%
100%
10
11
12
13
14
15
20
22
24
26
28
30
WARNING SIGNAL
Condition Warning signal cycle Shutdown signal cycle
Low battery alarm: BI BI BI (pause) BEE BEE BEE (pause) Over heating alarm: BI BI (pause) BEE BEE (pause) Over load alarm: BI BI BI BI BI BI Continuous tone Note: BI is a short beep, and BEE is a longer beep.
WHEN CONNECTED TO ANY APPLIANCE, BE SURE TO TURN ON INVERTER FIRST. AND THEN TURN ON THE POWER SWITCH OF THE APPLIANCE.
TURN ON SECONDLY
TURN ON FIRSTLY
ON
OFF
REMOTE CONTROL
OVER LOAD
OVER TEMP
NORMAL
LOAD
BATTERY
0%
50%
100%
10
11
12
13
14
15
20
22
24
26
28
30
CHASSIS EARTH:
THE CHASSIS EARTH LUG SHOULD BE CONNECTED TO AN EARTH POINT, WHICH WILL VARY DEPENDING ON WHER THE POWER INVERTER IS INSTALLED. IN A VEHICLE, CONNECT THE CHASSIS GROUND LUG TO THE CHASSIS OF THE VEHICLE. IN A BOAT, CONNECT TO THE BOAT’S GROUD SYSTEM. IN A FIXED LOCATION, CONNECT TO EARTH.
CHASSIS GROUND
LUG
WARNING: DO NOT REVERSE INPUT
FAN
IF THE TOTAL WATTS OF ELECTRICAL APPLIANCES EXCEEDS THE OUTPUT CAPACITY OF INVERTER. OR AFTER OPERATING FOR A PERIOD OF TIME. IF THE TEMPERATURE OF THE INVERTER REACHES 65, THE INVERTER SHALL BE REDUCED AC OUTPUT BY THE PROTECTION CIRCUIT.
0
65 C
Loading...