Popp IP44 Instruction Manual

Wall Plug Switch Schuko for Outdoor Use (IP44)
Manual
009105
Wall Plug Switch Schuko (IP44) – Manual
Quick Start ........................................................................................................................................................................... 2
Product Description ............................................................................................................................................................. 2
Before Installation ................................................................................................................................................................ 2
Installation Guidelines ......................................................................................................................................................... 3
Behavior within the Z-Wave Network .................................................................................................................................. 3
Operating the Device........................................................................................................................................................... 3
Child Protection ................................................................................................................................................................... 4
Association .......................................................................................................................................................................... 4
Configuration Parameters ................................................................................................................................................... 4
Command Classes .............................................................................................................................................................. 5
Technical Data .................................................................................................................................................................... 6
Explanation of Z-Wave specific Terms ............................................................................................................................... 6
Support ................................................................................................................................................................................ 7
Quick Start
This is a Z-Wave actuator. Inclusion and Exclusion are confirmed by a tripple click of the button. Fast blinking LED indicates the factory reset state.
Please refer to the chapters below for detailed information about all aspects of the products usage.
Product Description
This is a plug switch that can be placed between a wall outlet for Schuko plugs (plug type F) and electric devices, plugged in by cord. It can switch all loads up to 3500 W. The device is IP 44 rated and can therefore be used both in dry environments as well as humid environments and outdoor. Switching is controlled wirelessly using Z-Wave or locally applying a button. A multi color LED indicates the switching status and the assignment of the colors to the switching status can be defined by the user. The device will report any change of the switching status to a central gateway regardless the origin of the switch (local or wireless). A built in virtual power meter will report the power consumption of the load attached. However the user must configure the assumed constant power draw of the load. The local button can control the local load but can also be used to control other functions in a Z-Wave network. The device is certified and tested against all important European Safety Regulations and fully complies with the Z-Wave Plus standard. The device supports secure communication and the firmware can be upgraded over the air (OTA).
Before Installation
Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure an error-free functioning.
ATTENTION: Only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with 230 Volt mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching. The product is permitted only for proper use as specified in the user manual. Any kind of guarantee claim has to be forfeited if changes, modifications or painting are undertaken. The product must be checked for damages immediately after unpacking. In the case of damages, the product must not be operated in any case. If a danger-free operation of the equipment cannot be assured, the voltage supply has to be interrupted immediately and the equipment has to be protected from unintended operation.
Installation Guidelines
The plug can be plugged into every wall outlet for Plug-Type Schuko. It is IP44 rated and can therefore be used both in dry environments as well as humid environments and outdoor. Do not locate the device facing direct sunlight or dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C. Plugs must not be stacked and operated.
Configuration Menu
Keeping the button pressed for 5 seconds will enter the configuration menu. A blinking blue LED indicates that this menu was entered. Short click of the button will change the configuration option and a long (min. 2 seconds) click confirms the selection.
The following options are supported:
• Blue: Confirm firmware update
• Red: Local
Behavior within the Z-Wave Network
On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network – i.e. being excluded – sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to be reset first.
Inclusion and Exclusion are confirmed by a tripple click on the button.
Operating the Device
The device is able to switch electric loads up to 3500 W and can be switched wirelessly or using the local button.