Popp 004407 User Manual

1
Quick Start
This device is a Z-Wave sensor reporting Carbon Monoxide Danger. Pressing the 'Z-Wave button' for one second adds (includes) and removes (excludes) the device from/to the Z-Wave network.
Please refer to the chapters below for detailed information about all aspects of the product.
Manual
004407
2
Product Description
This product combines a certified carbon monoxide detector with a plug-in Z-Wave module to form a wirelessly reporting carbon monoxide sensor. The carbon monoxide detector is certified according to EN 50270:1999, EN 60335-1:1994 as well as EN 50291:2001 and satisfies all contemporary legal requirements.
The high-end carbon monoxide detector offers a test button conveniently accessible – e.g. with a broom stick – when mounted on the ceiling. Three colored LEDs on the device indicate Alarm, Error and Battery Level. The Alarm conditions as well as the actual CO level – measured in ppm – are reported wirelessly using Z-Wave. Additionally, a group of actuators can be controlled using the BASIC command class in case the CO alarm triggers. Two configuration parameters define what command to be sent in this case.
The device is a secure Z-Wave Plus device and can be used in one wireless Z-Wave network with other certified devices regardless of origin and brand. It supports secure communication if the central controller supports secure communication as well. Even if included securely the device is able to communicate unsecured with devices included unsecure using the association group 2. Beside the Carbon monoxide danger alarm the device will also report a tamper alarm if the sensor is removed from the mounting base.
Installation Guidelines
Please refer to the installation guide of the carbon sensor attached for information about how and where the carbon monoxide sensor should be installed. Please note that the carbon monoxide sensor will also work stand-alone even if no Z­Wave network is present.
The first step is to mount the mounting base on the desired place in the home using screws.
Remove the battery isolation strip from the wireless module. The red LED will start blinking.
Include the sensor into your existing Z-Wave based smart home network using the Z-Wave button.
Place the detector on the mounting base and turn clockwise. Now the detector is armed.
Battery change: The battery of the wireless module will be empty much earlier than the 10 years soldered in battery of the sensor. To replace the battery, deactivate the tamper alarm via central controller, remove the detector and pull off the wireless module from the carbon sensor. Then you can replace the 1/2 AA battery and re-plug the wireless module.
Behavior within the Z-Wave Network
On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is called Exclusion. The primary controller of the Z-Wave network initiates both processes. This controller will be turned into exclusion respective inclusion mode. Please refer to your primary controller’s manual on how to turn your controller into inclusion or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network - i.e. being excluded - sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to be reset first. Pressing the Z-Wave button for one second includes the device. If the button is pressed for at least 2 seconds, the inclusion will be done without the Security Command Class. A single click on the button will exclude the device.
Operating the Device
There is no defined level of carbon monoxide that will result in an alarm. The danger of CO is a result of the total level of CO in the air plus the duration of exposure. A Z-Wave alarm will be sent out when one of the following conditions were met:
CO level above 43 ppm for a duration of 60 minutes
CO level above 80 ppm for a duration of 10 minutes
CO level above 150 ppm for a duration of 2 minutes
Loading...