PoolRite SQI 400, SQI 600, SQI 700, SQI 500 User Manual

Page 1
Troubleshooting
Warning
Safe Use and Care
Warranty
Your new POOLRITE Qu ietline SQI Series Pump is manufactu red to the h ighest possi ble standard s and most u p-to­date tec hnology. Acc ordingly the equipment c arries the f ollowing war ranty, shoul d a fault oc cur due to f aulty manufact ure or mater ials. In th e event of a fault cover ed by warran ty occurring , the purcha ser must, in the first instance , contact Po olrite Equip ment Pty Ltd or the clos est authoris ed distribut or.
1. The warr anty covers the Quietlin e SQI Series Pump and ex tends to the workmanship and materia ls used in t he manufact ure of the u nit only. P OOLRITE spec ifically dis claims any l iability for any consequ ential loss or
damage w hich may res ult from the use of the Quietline SQ I Series Pum p.
2. The Quie tline SQI Se ries Pump is warranted a gainst manuf acturing def ects only fo r a period o f 3 years f rom date of purch ase, in whic h event POOL RITE shall, as its sole operation, e ither repair or replace such damaged units delivere d to POOLRIT E or its aut horised dist ributor.
3. This war ranty extend s only to:
(i) within t he borders o f Australia and New Zeal and. (ii) A Quietl ine SQI Seri es Pump that is installe d and mainta ined strictl y in accorda nce with POOLRITE ’s instructi ons, and/or installed by agents duly authorised by POOLRITE without alte rations or modif ications of any nature w hatsoever. (iii) The Quie tline SQI Se ries Pump re turned to th e distributo r from which it was purc hased or to POOLRITE at the purc haser’s expe nse.
4. This war ranty exclud es:
(i) Damage a rising from abnormal use , lack of ca re, extreme exposure to the elements or chemical s or fact beyond t he control o f POOLRITE. (ii) The POOL RITE warrant y supersedes all other w arranties wh ether expres sed or impli ed.
POOLRITE accepts no responsibil ity for loss , damage or injury to pe rson or prop erty arising from warran ty failure o f equipmen t, or instal lation of th at equipment . Unless wi th the expre ss authority of POOLRITE any repair or replacem ent shall be provided on ly by POOLRI TE or its au thorised Dis tributors an d this warra nty shall no t extend to any expe nditure othe rwise incurr ed.
If the Pump and Motor runs but there is little or no wate r flow, th e followin g conditio ns may app ly:
Check to see if th e
Filter n eeds clean ing
or is bl ocked.
Pump is not primed . Air leaks in suction
lines .
Blockage s Water on ground und er
the Pump and Motor
usually indicates a
damaged Pump Shaft
Seal
Pump una ble to dra w
water fr om the poo l
Refer to
Filter I nstruction
Manual.
Re-prime as per
instruct ions in
“Startin g
Pump”.
Check fo r air bubb les
under Cl ear Lid an d
tighten.
Check St rainer Bas ket
and Pool Skimmer Basket a re free of
obstruct ion.
This sho uld be
repaired immediate ly
or furth er damage
may occu r.
Check St rainer Bas ket
and Pool Skimmer Basket a re free of
obstruct ion. If a
blockage is suspec ted
inside t he Pump or in the P ipework th e advice o f your poo l
ician sh ould
be sough t.
Check po wer point by pluggin g in a portable appliance to ensure power
is avail able. Also check Fus es and
Main Pow er Supply Switch
Poolrite Motors in corporate an
Internal Switch th at will re set automati cally afte r the Moto r
has cool ed.
If a Pum p or Pipew ork blocka ge is
suspecte d that is preventing the
motor fr om rotatin g, the adv ice of
your poo l service technician should
be sough t.
“Burning ” smell ev ident -
replacem ent
may be r equired.
The Pump Motor is an electrica l device a nd as such should no t be disass embled or serviced b y anyone o ther than an authoris ed Poolrit e Service Technician or qualif ied Elec-
tricial S ervice Com pany. This appliance is not int ended for use by you ng children or infirm persons u nless they have been adequately supervise d by a res ponsible p erson to
ensure th at they ca n use the a ppliance s afely.
Young chi ldren shou ld be super vised to e nsure that they do n ot play wi th the appl iance.
Also, any other pro blems that cannot be corrected by routine maintenan ce should b e attended to by an experience d Pool Ser vice Techni cian.
If the motor doe s not run, the probl em could b e that:
Power no t connecte d Overload tripped Blockage preventin g Pump fro m
rotating .
Motor fu sed or “bu rnt out”
union adapter
union adapter
strainer basket
strainer port
suction port
150mm (min)
pump body
discharge port
clear lid
20703
Page 2
Automatic Operating Switch Setting
Move the slide switch on the face of the Time Switch down to the position marked “AUTO”. The Filter pump and cell should now operate when the next ON cycle is detected by the Time Switch (if the Chlorine Control is correctly adjusted).
To manually turn the lter pump and cell off, move the slide switch to the centre “OFF” position.
OperationInstallation
Location Starting the Pump
Pipe Connection
Routine Maintenance
Water Leaks
Motor Noise
Large Air Bubbles Under Strainer Pot Lid
Chemical Balance Guide
Weather Protection
Power Connection
Install at a distance no more than 12 metres from the Pool or Spa and no more than 1 metre above water level or 1 metre below water level. If the pool is to be installed outside these parameters, seek the advice of your local Poolrite Distributor.
First prime the Pump by removing the Clear Lid by loosening the Clamp Knobs and allowing them to swing aside. Fill the Strainer Pot with water to the Suction Port. Replace the Lid ensuring that it is sealed on the Gasket properly. Do not overtighten the Clamp Knobs.
Before switching the pump ON check that all Pipework is properly sealed and that the pool water is at the recommended level (check with your Pool Builder).
The SQI Pump is completely Weatherproof and therefore no enclosure is necessary. However should it be desirable to install the Pump in an enclosure, the enclosure must have both a ventilation inlet and outlet opening to allow cooling airflow around the Pump Motor. Each opening should be at least 200 sq cm in area as close as practicable to the Pump.
The Quietline Pump is designed to be connected to a nominal 240 volt 50Hz power supply and is supplied with a 1.8 metre lead and 3 Pin Plug. A Weatherproof 3 Pin Power Point should be fitted by an electrician in a dry place, shielded from pool water splash over.
EXTENSION LEADS ARE NOT RECOMMENDED FOR USE WITH THIS EQUIPMENT BECAUSE THEY ARE UNSAFE IN AND AROUND THE POOL ZONE.
The Pump should be placed on a secure and level concrete or similar base 600 x 300mm in size (Pump only) and should be placed in a location that cannot be flooded by storm water or by accidental immersion.
Connect to power supply and switch ON.The rear of the Motor should be no closer than 150mm from a wall, fence or any other barrier to allow for adequate airflow to cool the
Motor.
Allow Pump to run discharging the water back to the pool.
If flow is not established within approximately 1 minute, switch off the Pump and repeat procedure. Continued failure to prime may indicate an air leak in the suction line which should be rectified.
The Suction and Discharge Ports are provided with Union Adaptors for quick disconnection. These connectors will accept either 40mm or 50mm PVC pipe and should be joined to the pipe with PVC Solvent Cement. Suction lines should be no smaller than as follows:-
Switch off Pump.
Water leaking from under the Pump and Motor should be attended to immediately as this would indicate a failure of the Pump Shaft Seal. If this seal is not immediately replaced damage may occur.
If the Pump Motor starts to get “noisy” the Motor should be checked by a Pool Technician to ascertain whether the Motor Bearings need replacement. This should be attended to immediately as Bearing failure may cause Motor burn out.
Check the Gasket under the Clear Lid and check the pipe connection to the Suction Port at the front of the Pump to make sure it is tight
- do not overtighten.
Your SQI Pump is designed to be used for swimming pool water, which needs to be balanced in accordance with Langlier Saturation Index, with a pH level of 7.0 to 7.8 and maintains the recommended levels of sanitizer. (i.e 2 - 3 ppm of free chlorine). Regular water analysis and advice on correct addition of chemicals and/or products to achieve suitable water quality and balance by a reputable professional pool shop will ensure bather health and comfort and extended equipment service life.
Pool water leaking onto the pump motor from associated plumbing should be attended to immediately before damage occurs.
Remove Clear Lid.
Remove Strainer Basket.
Empty accumulated rubbish and hose Strainer Basket clean.
Replace Strainer Basket.
If Strainer Pot has emptied of water, repeat steps in “Starting the Pump”.
The Strainer Basket should be inspected frequently through the Clear Lid and emptied as follows when a build-up of rubbish is evident.
Discharge pipe should be no smaller than 40mm for Pump sizes SQI 400, SQI 500 and SQI 600. Pump SQI 700 should use 50mm pipe.
When installed below water level, Shut-off Valves should be fitted to the Suction and Discharge Lines which should be free from air leaks. The discharge from the Pump Outlet should be connected to the Inlet of the Filter and the Suction Port connected to the Skimmer Box or Suction Outlet from the Pool or Spa.
please go to www.poolrite.com for full product manual
Pump
Model
Max Su ction
Line L ength
Min PV C pipe s ize
SQI 40 0 12m 50mm
SQI 50 0 12m 50mm
SQI 60 0 12m 50mm
SQI 00 12m 2 x 50mm
1
1
1
1
2
2
3
3
4
1
1
1
1
1
1
2
2
3
4
5
6
2
Loading...