Ponovo PCT Auto-Test Box User Manual

PONOVO POWER CO., LTD
Office
E-Mail
Info@relaytest.com
Website
www.relaytest.com / www.ponovo.com.cn
PCT Auto-Test Box User Manual
No. 139 Jinghai Third Road, BDA, Beijing, China, 100176
VERSION: AUTO-TEST BOX -AE-1.0 DATE: JAN 2018
This manual is the publication of PONOVO POWER CO., LTD. Any form of copy should obtain the consent of it.
This manual represents the technical status for the moment of publishing. The product information, description and specifications mentioned in the manual do not have any contact binding force and PONOVO POWER CO., LTD remains the right to make modifications to the technical specifications and configurations without prior notice. PONOVO POWER PONOVO explicitly exonerates itself from all liability for mistakes in this manual
PCT Auto-Test Box User Manual
Content
1. Preface ............................................................................................................................ 3
2. Introduction and application ......................................................................................... 5
3. Hardware ......................................................................................................................... 6
4. Testing and wiring .......................................................................................................... 8
2
PCT Auto-Test Box User Manual

1. Preface

Notes:
The PCT box is specially designed for the CTs with multi-ratios. The wiring change or connection during testing is prohibited.
Safety rules
Please read the instructions carefully before operating the PCT auto-test box. If you don’t understand some safety rules, please contact PON OVO POWER CO., LTD before operation. The PCT auto-test box is specially designed for use with PCT200i or PCT200Ai. Therefore, follow the safety rules both in this user manual and PCT200 User M anual when proceeding with the PCT auto-test box. Maintenance and repair should be carried on in the factory or the certified maintenance center.
General
Strictly follow the five safety rules below:
Disconnect completely  Secure from reconnection  Verify that the installation is dead  Carry out grounding and short-circuiting  Provide protection against adjacent live parts
Measures
The PCT auto-test box user manual or the e-manual has t o be available at the site where the PCT box is used. All users of the PCT box must read and fol l ow the safety rules and all the instructions for installation and operation.
The PCT auto-test box can only be used as the desc ribed in t his user manual. Any other application is not allowed in accordance with the regulations. The manufacturer is not liable for the damage from improper usage. The user assum es all responsibility and risk.
3
PCT Auto-Test Box User Manual
Full compliance with the regulations also includ es f ol lowing the instructions provided in this user manual.
Power supply
The power supply is 110-240V AC with protective ground.
Safe operation
Make sure to put the test equipment on dry and solid ground.  If working in other than laboratory environment only use the PCT auto-test box with a
2
solid connection to ground of at least 6mm the test object.
Do not open the PCT auto-test box. Opening the PCT auto-test box inval i dates all
warranty claims.
Do not repair, modify, extend or adapt the PCT auto-test box or any acces sory .
. Use a ground point as close as possible to
Do not operate the PCT auto-test box under wet or most conditions.  Do not operate the PCT auto-test box when explosive gas or vapors are present.  Check if there is any visible damage before putting the PCT auto-test box into operation.  Use the PCT auto-test box only in a technically sound condition and when its use is in
accordance with the safety regulations for the sp ecific job site and application.
Always be aware of the danger of the high voltages and currents associat ed with this
equipment. Pay attention to the information provi ded in this user manual.
When disconnecting cables, always start at the device feeding the power.  Never connect or disconnect the test object while the outputs of the connected PCT200i
or PCT200Ai.
For protection against parasitic current or voltage, always connect the equipmential
connector on the PCT auto-test box to protective ground.
Make sure that the terminals of the test object to be connected to the PCT auto-test box
do not carry any voltage potential. During a test, the PCT200i or PCT200Ai (with the PCT auto-test box connected) is the only permitted power source for the test object.
Only use wires with 4mm safety “banana” connectors and plastic h ousing for connection
to the front panel input/output sockets.
4