PolyScience Standard Controller Models, Standard Controller Operator's Manual

Operators Manual
Standard Controller Models
Pages 1 - 22
Manuel de l’utilisateur
Modèles du Contrôleur Standard
Bedienungsanleitung
Geräte mit Standardregelung
Seiten 38 - 54
110-227 1/8/08
EC Declaration of Conformity
The Products herewith complies with the requirements, as stated below, in accordance to the EC Low Voltage Directive 73/23/EEC and EC Electromagnetic Compatibility Directive 89/336/EEC, and carries the marking
accordingly. We herewith declare:
That the following equipment complies with the essential requirements in respect to safety and health, in accordance to the EC Directives based on its design and type, as brought into circulation by us. In case of alteration of the equipment, not agreed upon by us, this will lose its validity.
Product Description: Refrigerated/Heated Circulators
Applicable Directives and Harmonized Standards:
Testing Bodies:
PolyScience Division of Preston Industries, Inc. 6600 West Touhy Avenue P.O. Box 48312 Niles, Illinois 60714, USA
13R, 712, 7306, 7312, 812, 8006, 8012, 8002, 8112, 8102, 8106, 8202, 8212, 8206, 8306, 9006, 9012, 9002, 912, 9112, 9102, 9106, 9502, 9512, 9506, 9602, 9612, 9606, 9702, 9712, 9706;
18203, 18214, 18211, 18210, 18201, 18206, 18205, 18208, 18212, 18207, 18225, 18226, 18202;
13270-879, 13270-880, 1112A, 1122S, 1127P, 1146D, 1140S, 1147P, 1162A, 1166D, 1160S, 1167P, 1156D, 1150S, 1157P, 1196D, 1190S, 1197P, 1186D, 1180S, 1187P, 1136D, 1130S, 1137P, 1136-1D, 1130-1S, 1137-1P, 1136-2D, 1130-2S, 1137-2P;
12110-00, 12110-05, 12112-01, 12112-06, 12112-11, 12112-16, 12112­12, 12112-26, 12100-10, 12100-15, 12100-20, 12100-25, 12108-00, 12108-05, 12108-20, 12108-25, 12108-10, 12108-15, 12108-30, 12108­35, 12102-10, 12102-15, 12102-00, 12102-05, 12103-20, 12103-25, 12105-70, 12105-75, 12101-41, 12101-46, 12101-31, 12101-36, 12101­51, 12101-56, 12111-11, 12111-16, 12111-01, 12111-06, 12111-21, 12111-26, 12107-00, 12107-05, 12107-20, 12107-25, 12107-10, 12107­15, 12107-30, 12107-35, 12107-50, 12107-55, 12107-40, 12107-45, 12107-60, 12107-65, 98928-30, 98928-35.
Low Voltage Directive 73/23/EEC & Electromagnetic Compatibility 89/336/EEC and relevant transpositions into national law of the member states, including, but not limited to the following Harmonized Standards: EN/IEC 61010-1: 2001 EN/IEC 61010-2 EN 61326: 1997 +A1: 1998 + A2:2001 CISPR 11/EN 55011 Class A, Group I
CSA International (Certification & Testing Division) Ultra Tech Inc. ( EMC approval)
Signature on Behalf of Manufacturer or Authorized Representative: Date of Validity: Title of Signatory:
110-254 Rev. E 10/05
Brian Klotz October 18, 2005 Engineering Manager
WEEE Directive
A label with a crossed-out wheeled bin symbol and a rectangular bar indicates that the product is covered by the Waste Electrical and Electronic Equipment (WEEE) Directive and is not to be disposed of as unsorted municipal waste.
Any products marked with this symbol must be collected separately, according to the regulatory guidelines in your area.
The objectives of this program are to preserve, protect and improve the quality of the environment, protect human health, and utilize natural resources prudently and rationally. Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream. Such treatment is the most effective means of protecting the customer’s environment.
Requirements for waste collection, reuse, recycling, and recovery programs vary by regulatory authority at your location.
Contact your local responsible body (e.g., your laboratory manager) or authorized representative for information regarding applicable disposal regulations.
Contact PolyScience at the web site listed below for information.
Web address: www.polyscience.com
Customer Care: 1-800-229-7569 (inside the USA) (+1) 847-647-0611 (outside the USA) Fax 1-847-647-1155
or
13R, 712, 7306, 7312, 812, 8006, 8012, 8002, 8112, 8102, 8106, 8202, 8212, 8206, 8306, 9006, 9012, 9002, 912, 9112, 9102, 9106, 9502, 9512, 9506, 9602, 9612, 9606, 9702, 9712, 9706;
18203, 18214, 18211, 18210, 18201, 18206, 18205, 18208, 18212, 18207, 18225, 18226, 18202;
13270-879, 13270-880, 1112A, 1122S, 1127P, 1146D, 1140S, 1147P, 1162A, 1166D, 1160S, 1167P, 1156D, 1150S, 1157P, 1196D, 1190S, 1197P, 1186D, 1180S, 1187P, 1136D, 1130S, 1137P, 1136-1D, 1130-1S, 1137-1P, 1136-2D, 1130-2S, 1137-2P;
12110-00, 12110-05, 12112-01, 12112-06, 12112-11, 12112-16, 12112-12, 12112-26, 12100-10, 12100-15, 12100-20, 12100-25, 12108-00, 12108-05, 12108-20, 12108-25, 12108-10, 12108-15, 12108-30, 12108-35, 12102-10, 12102-15, 12102-00, 12102-05, 12103-20, 12103-25, 12105-70, 12105-75, 12101-41, 12101-46, 12101-31, 12101-36, 12101-51, 12101-56, 12111-11, 12111-16, 12111-01, 12111-06, 12111-21, 12111-26, 12107-00, 12107-05, 12107-20, 12107-25, 12107-10, 12107-15, 12107-30, 12107-35, 12107-50, 12107-55, 12107-40, 12107-45, 12107-60, 12107-65, 98928-30, 98928-35
100-151
712, 7306, 7312, 812, 8006, 8012, 8002, 8112, 8102, 8106, 8202, 8212, 8206, 8306, 9006, 9012, 9002, 912, 9112, 9102, 9106, 9502, 9512, 9506, 9602, 9612, 9606, 9702, 9712, 9706;
18203, 18214, 18211, 18210, 18201, 18206, 18205, 18208, 18212, 18207, 18225, 18226, 18202;
13270-879, 13270-880, 1112A, 1122S, 1127P, 1146D, 1140S, 1147P, 1162A, 1166D, 1160S, 1167P, 1156D, 1150S, 1157P, 1196D, 1190S, 1197P, 1186D, 1180S, 1187P, 1136D, 1130S, 1137P, 1136-1D, 1130-1S, 1137-1P, 1136-2D, 1130-2S, 1137-2P;
12110-00, 12110-05, 12112-01, 12112-06, 12112-11, 12112-16, 12112-12, 12112-26, 12100-10, 12100-15, 12100-20, 12100-25, 12108-00, 12108-05, 12108-20, 12108-25, 12108-10, 12108-15, 12108-30, 12108-35, 12102-10, 12102-15, 12102-00, 12102-05, 12103-20, 12103-25, 12105-70, 12105-75, 12101-41, 12101-46, 12101-31, 12101-36, 12101-51, 12101-56, 12111-11, 12111-16, 12111-01, 12111-06, 12111-21, 12111-26, 12107-00, 12107-05, 12107-20, 12107-25, 12107-10, 12107-15, 12107-30, 12107-35, 12107-50, 12107-55, 12107-40, 12107-45, 12107-60, 12107-65, 98928-30, 98928-35
100-150
Table of Contents
Section 1 – General Information
1.1 Warranty
1.2 Unpacking
Section 2 – Circulating Bath
2.1 Contents
2.2 General Description
2.3 Circulator Pump
2.4 Pump Inlet and Outlet Connections
2.5 Closed Loop Circulation
2.6 Filling the Reservoir
2.7 Reservoir Purge
Section 3 – Immersion Circulator
3.1 Contents
3.2 General Description
3.3 Circulator Pump
3.4 Set-Up
3.5 Connections to External Apparatus
3.6 Attainable Temperatures
Section 4 – Standard Controller Information
4.1 Front and Rear Panels
4.2 Heater/Pump Assembly
4.3 Specifications
Section 5 – Operation
5.1 Circulator Location
5.2 Reservoir Liquid Level
5.3 Power
5.4 Setting the Safety Set Set Point
5.5 Selecting Temperature Units
5.6 Setting the Software High Limit
5.7 Setting the Set point Temperature
5.8 User-Defined Preset Temperatures
5.9 Local Lockout Feature
5.10 Stick-on Strips for Preset Buttons
5.11 Auto-Refrigeration Operation
5.12 Controller Display Messages
Section 6 – Calibration and Maintenance
6.1. Calibration
6.2 Heater
6.3 Pump Motor
6.4 Cleaning
6.5 Maintaining Clear Bath Water
6.6 Condenser, Air Vents, and Reusable Filter (Refrigerating/Heating Circulators only)
Section 7 – Troubleshooting
7.1 Unit Will Not Operate (No Heat, Cooling, or Pumping)
7.2 No Pumping
7.3 Slow or Insufficient Pumping
7.4 No Heating
7.5 Insufficient Heating
7.6 No Cooling or Insufficient Cooling
7.7 Triac Failure
Section 8 – Reservoir Fluids
Section 9 – Service and Technical Support
Section 10 – Replacement Parts
Section 1 - General Information
1.1 Warranty
Thank you for purchasing this circulator. We are confident it will serve you for a long time. Our warranty to you is as follows:
The manufacturer agrees to correct for the original user of this product, either by repair, or at the manufacturer's election, by replacement, any defect that develops after delivery of this product within the period as stated on the warranty card. In the event of replacement, the replacement unit will be warranted for 90 days or warranted for the remainder of the original unit’s parts or labor warranty period, whichever is longer.
If this product requires service, contact the manufacturer/supplier's office for instructions. When return of the product is necessary, a return authorization number will be assigned and the product should be shipped, (transportation charges pre-paid), to the indicated service center. To insure prompt handling, the return authorization number should be placed on the outside of the package and a detailed explanation of the defect enclosed with the item.
This warranty shall not apply if the defect or malfunction was caused by accident, neglect, unreasonable use, improper service, or other causes not arising out of defects in material or workmanship. There are no warranties, expressed or implied, including, but not limited to, those of merchantability or fitness for a particular purpose which extends beyond the description and period set forth herein.
The manufacturer's sole obligation under this warranty is limited to the repair or replacement of a defective product and shall not, in any event, be liable for any incidental or consequential damages of any kind resulting from use or possession of this product. Some states do not allow: (A) limitations on how long an implied warranty lasts; or (B) the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights. You may have other rights that vary from state to state.
1.2 Unpacking
Your circulator is shipped in a special carton. Retain the carton and all packing materials until the unit is completely assembled and working properly. Set up and run the unit immediately to confirm proper operation. Beyond one week, your unit may be warranty repaired, but not replaced. If the unit is damaged or does not operate properly, contact the transportation company, file a damage claim and contact the company where your unit was purchased immediately.
Remove any loose packing material that may have fallen into the reservoir during shipping. Before powering up, check that nothing remains around the heater or circulator pump.
The instructions in this manual pertain to both circulating baths as well as the immersion circulator. Read the section pertaining to the special instructions for your model, then review the instructions for all models of circulators.
This symbol marks chapters and sections of this instruction manual which are particularly relevant to safety.
This symbol indicates that hazardous voltages may be present.
Read all instructions pertaining to safety, set-up, and operation.
Proper operation is the users’ responsibility.
Loading...
+ 15 hidden pages