Safety Instruction
Before starting work on the appliance, switch off power supply and secure against switching on.
Positioning
The room thermostat should be positioned away from direct sunlight or heat producing appliances. It is recommended that the thermostat is installed 1·2 metres above floor level.
Installation
Step 1:
Open front and rear case with screwdriver, then take off the front case
Step 2:
Open relay case with screwdriver and take off the relay case
Step 3:
Connect all wires properly (See page 2)
Step 4:
Cover the relay case and screw it properly with screwdriver
Step 5:
Mount and fix rear case with screws in wall
Step 6:
Put 2 x 1·5v AA batteries into battery box observing polarity
Step 7:
Cover front and rear case correctly
COM
NC
NO
2
NO
COM
NC
NO
COM
NC
Wiring details for single zone master unit (PB1ZM)
Wiring details for 4 zone and 6 zone slave (PB4ZS and PB6ZS)
3
4
Time Setting
a) Press the key to flash the following in order:
Year, Month, Day, Hour, Minute.
Use the + or – key to adjust each b) Press OK when complete to confirm exit Note: The internal calendar will calculate the correct day of the week (1=Monday etc.) Note: The time with change automatically to adjust BST and GMT on the correct date.
Temperature Setting
There are 3 temperature settings available: Comfort used when room is permanently occupied e.g. 21°C Economy used when room is temporarily occupied e.g. 18°C Night used when the room is unoccupied e.g. 15°C a) Press the key to flash the following in order:
Comfort, Economy, Night. Use the + or – key to adjust each b) Press OK when complete to confirm exit.
Mode Setting
a) Press the key to select the following: Automatic (programme mode). The display will also show the current temperature at that time e.g. or Continuous operating at comfort temperature Continuous operating at economy temperature Continuous operating at night temperature Continuous operating at frost protection setting (+7°C)
Quick Set Up
To enable quick set up of the Thermostat, there is a pre­installed programme. Simply enter the year, date and time. Then switch to Auto. The programme for each day will be as follows:
6.00 a.m. - 8.00 a.m. Comfort setting Set at 21°C
8.00 a.m. - 6.00 p.m. Economy setting Set at 18°C
6.00 p.m. - 11.00 a.m. Comfort setting Set at 21°C
11.00 a.m. - 8.00 a.m. Night setting Set at 15°C To change any of the temperatures for these times see Temperature Setting Instructions. To enter different heating times for each day proceed to Programme Setting Instructions.
Programme Setting
There are three different kinds of programme during the automatic mode. That is: Daily programme (different programme for each day of a week), 5/2 programme (the same programme for Monday (1) - Friday (2) and the same programme for Saturday (6) - Sunday (7)), Weekly programme (the same programme for each day of a week).
Daily Programme
a) Press and hold key for 3 seconds to flash the day (1-7) b) Press + or – key to set the day which you want to programme c) After setting the day/days, press key to flash time 0:00
and the corresponding bar dot for programme is flashing
d) Press key to enter into energy saving mode; press key to
enter into comfort (sun) mode; press key to enter into night (moon) mode
e) Press + or – key to adjust time. Repeat step d) and e) if you
want to change the programmed level temperature
f) When you finish setting one day programme,
press to flash day
g) Set the rest days’ programme of a week as above operation
from step b) to step f), after finishing all settings, press OK to confirm and exit, or exit automatically in 1 minute (after 15 seconds the display will switch off).
5/2 Programme
a) Press and hold key for 3 seconds to flash date b) Press + or – key to select days from 1 to 5 (these days are
flashing)
c) Set the programme for Monday-Friday and Saturday-Sunday
by using the same way as Daily Programme A operation
Weekly Programme
a) Press and hold key for 3 seconds to flash date b) Press the + or – key to select days from 1 to 5 (these days
are flashing)
c) Set the programme by using the same method as Daily
Programme operation.
Copy Function
a) Press and hold key for 3 seconds to flash day and enter into
COPY mode when you are in automatic mode The day and COPY are flashing
b) Press the + or – key to choose the programme of target day
which you want to copy from
c) Press the key again to stop flashing COPY (the programme
is memorised
d) Press + or – key to choose the day which you want to copy
the programme to e) Press the key again, the programme has been downloaded f) In the same way to copy and download programme to the
rest days, after finishing all programmes, press OK to confirm
and exit, or exit automatically in 1 minute (after 15 seconds
the display will switch off).
5
Manual Override Function
During the automatic mode you can have the override function Temporary override (Party) a) Press + or – key to adjust override temperature: the symbol
indicator will appear on the display
b) After setting the temperature, press OK key to confirm and
exit, or exit automatically in 1 minute (after 15 seconds the display will switch off). The manual setting temperature and will be kept until entering next setting programme or
when pressing OK key Hold hours a) Press + or – key to adjust override temperature: the symbol
indicator will appear on the display b) Press key once to display 1H and indicator c) Press + or – key to set holding time from 1 hour to 24 hours d) Press OK key to confirm and exit, or exit automatically in
1 minute (after 15 seconds the display will switch off).
The number of hours and the override temperature are
flashing alternately on the top right side of the display.
Press OK to exit from the override function.
Hold Days (Holiday)
a) Press + or – key to adjust override temperature: the symbol
indicator will appear on the display b) Press key twice to display 1d and indicator c) Press OK key to confirm and exit, or exit automatically
in 1 minute (after 15 seconds the display will switch off).
The number of hours and the override temperature are
flashing alternatively on the top right side of the display.
Press OK for exit from the override function.
Hold Long Period Running
a) Press + or – key to adjust override temperature: the symbol
indicator will appear on the display b) Press key three times and will display c) Press OK key to confirm and exit, or exit automatically
in 1 minute (after 15 seconds the display will switch off).
The temperature will be kept until manually pressing OK key.
Alarm Setting
a) Press and hold key for 3 seconds to display AL b) Then press key once to display on the top left.
Press + or – key to select the days (1-5, 6-7, 1-7)
c) Press key once to flash hour. Press + or – key to set hours
of alarm clock
d) Press key once again to flash minute. Press + or – key
to set minutes of alarm clock
e) Press OK to confirm. After finishing the setting time, buzzer
ring BI-BI for 30 seconds to the programmed time. Press OK key to turn off the alarm clock in the midway.
To Cancel Alarm
a) Press and hold key for 3 seconds to display b) Then press and will disappear, press OK key to confirm
and cancel alarm or exit automatically (after 15 seconds the display will switch off).
Low Battery Indicator
When low battery occurs the symbol will appear on the display. Change the batteries in a few minutes and the programme, temperatures and date setting will remain in memory, you only need to reset the time clock (hours and minutes)
Key Lockout Function
Hold OK key for 3 seconds to display OK only, all keys will be locked out. To unlock the keys, hold the OK key for 3 seconds to restore the display of the keys. Use this function when for example you need to clean the display.
6
Technical Data
Dimension H x L x W (mm) 87 x 135 x 32
Operating voltage 2 batteries 1.5v LR6/AA
Temperature control range +5°C / +35°C
Temperature display range +5°C / +37°C
Switching capacity (changeover contact) at ohmic loads max 6a 240v 50hz at inductive loads cos w = 0.6 max 2a 240v 50hz
Switching output Floating
Function modes Heat / Cool
Anti-frost +7°C
Ambient temperature –5°C / +45°C
Programming Daily, Weekly and 5/2
Class of protection II
Index of protection IP20
Displayed temperature update 10s
Reading accuracy +/–1°C at 20°C
Reading resolution +/–0.1°C
Swing 0.2°C
Comply with EMC and LV directives
LVD: EN60730-1, EN60730-2-7, EN 60730-2-9
EMC: EN 55014-1, EN 55014-2, EN 61000-3-2, EN61000-3-3
Subject to technical modifications
Touch Screen Programmable
Room Thermostat
Polypipe Building Products
Broomhouse Lane
Edlington
Doncaster DN12 1ES
Tel: 01709 770 000
Fax: 01709 770 001
www.ufch.com
2410 London Road
Mount Vernon
Glasgow G32 8XZ
Tel: 0141 778 8822
Fax: 0141 778 2703
Dromore Road
Lurgan, Craigavon
Co. Armagh BT66 7HL
Tel: 028 38 881270
Fax: 028 38 882344
www.polypipe.com
Loading...