Polycom SPECTRALINK 6100 User Manual

SpectraLink 6100 MCU Quick Reference
Register a Wireless Telephone (handset)
1 Make sure all unregistered handsets are
2 Move the mode switch to the
position.
3 Press the
to be registered is flashing red. Only unregistered lines can be registered.
4 Press
registered and wait at least three seconds. The LED should change to solid red once the phone is registered.
5 Return the mode switch to the
position.
6 To assign the extension number, hold
down the
Volume Level displays. Press the # > key until EXTENSION displays on the handset. Press 0, then enter the correct extension number.
7 When the handset is turned on, the
extension will be displayed. Test the handset by placing a call to each handset to verify that the correct handset rings.
STEP button until the desired line
PWR on the handset that needs to be
FCN key on the handset until
REGISTER
NORMAL
PN: 1725-36098-001_D
Unregister a Wireless Telephone
1 Move the mode switch on the MCU to the
REGISTER position. If your system has more
than one MCU, be sure to move the switch on the correct MCU. The line indicator LEDs now show which lines have handsets registered.
2 Use the
unregistered. The line indicator LED for a line that has a handset registered to it will flash with the LED mainly on.
3 Press the
indicator LED for the selected line will be off with a short on flash.
4 Register the new handset or return the
mode switch to the
STEP button to select the line to be
DEL/ENTER button. The line
NORMAL position.
technicalsupport@polycom.com • 800.775.5330
SpectraLink 6100 MCU: Quick Reference
MCU Status LED Codes
ERROR LED STATUS LEDs Description
OFF Random Cycling The SpectraLink 6100 MCU is powering up. Initialization to follow. OFF 5 The SpectraLink 6100 MCU is initializing. Code number will change when finished. OFF 1, 2, 3, or 4 MCU identification number.
ON 1, 2, 3, 4, 5 MCU has not been configured for switch interface type. Assign a switch type to the
ON 4, 5 The switch type selected is not supported by this MCU. Verify that the switch type
ON 1, 3 A Base Station has reported an internal problem. Replace the Base Station. The error
ON 2, 3 No communication with one or more Base Stations on this MCU. The error display
ON 1, 2, 3 Internal communication problem with the MCU. Power cycle the MCU. If the problem
ON 4 IPC Problem. Check IPC cabling by disconnecting and reconnecting the IPC cable
ON 1, 4 The operator is trying to register a handset on an MCU with no phone lines. Return
ON 2, 4 The MCU was powered on with the mode switch in the wrong position. Turn off the
ON 3, 4 Configurations on a multi-MCU installation do not match in each of the units. Most
ON 1, 3, 4
ON 2, 3, 4 The MCU was powered on with the mode switch in the wrong position. Turn off the
ON 1, 2, 3, 4 Internal problem with the MCU. Contact Polycom Customer Service for technical
ON 1, 5 Possible Base Station failure. A Base Station that had previously been heard by
ON 5 One or more of the Base Stations on this unit is disabled because it is located too
ON 3, 5 The MCUs have incompatible versions of software. Contact Polycom Customer
MCU.
selected is correct. If the type is incorrect, repeat the steps to select a new switch type.
display refers to the Base Station LED that is flashing red. If more than one Base Station LED is flashing red, it refers to the lowest numbered Base Station.
refers to the LED that is flashing red. If more than one Base Station LED is flashing red, it refers to the lowest numbered Base Station.
persists, replace the MCU.
joining the MCUs. Connect the Male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector (A or B) on each MCU. If error still occurs, replace the IPC cable. Replace the MCU if the problem continues.
the mode switch to the NORMAL position.
MCU, move the mode switch to the NORMAL position and turn back on.
likely to occur when an MCU was just added to the system. Erase the configuration in the MCU with incorrect configuration definitions (probably the MCU that was just added).
Note: Do not erase the configurations in all the MCUs. In multiple MCU installations
the handset registration information is shared among the MCUs. This allows you to replace an MCU without re-registering all the handsets.
REGISTER or ADMIN mode selected on more than one MCU at the same time. Check the MCUs and take one of them out of REGISTER or ADMIN mode. OR The operator is trying to place an admin call on MCU #1 with no handset registered to MCU #1, Line 2. Return the mode switch to the NORMAL position.
unit, move the mode switch to the NORMAL position and turn back on.
support.
another Base Station can no longer be heard. Turn off the MCU, move the mode switch to the NORMAL position and turn back on. Check to see if system was powered on with mode switch in the wrong position. If not, contact Polycom Customer Service.
close to another Base Station. The error display refers to the Base Station LED that is flashing red. If more than one Base Station LED is flashing red, it refers to the lowest numbered Base Station. Identify which Base Station is disabled and move it away from the nearest Base Station.
Service for technical support.
2
PN: 1725-36098-001_D.doc
Loading...