Polycom DOC2559A User Manual

Polycom® RMX® 4000 Hardware Guide
Version
6.0
| August 2010 | DOC2559A
Polycom®, the Polycom “Triangles” logo, and the names and marks associated with Polycom’s products are trademarks and/or service marks of Polycom, Inc., and are registered and/or common-law marks in the United States and various other countries.
All other trademarks are the property of their respective owners.
Patent Information
The accompanying product is protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc.
© 2010 Polycom, Inc. All rights reserved.
Polycom, Inc. 4750 Willow Road Pleasanton, CA 94588-2708 USA
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Polycom, Inc. Under the law, reproducing includes translating into another language or format. As between the parties, Polycom, Inc., retains title to and ownership of all proprietary rights with respect to the software contained within its products. The software is protected by United States copyright laws and international treaty provision. Therefore, you must treat the software like any other copyrighted material (e.g., a book or sound recording).
Every effort has been made to ensure that the information in this manual is accurate. Polycom, Inc., is not responsible for printing or clerical errors. Information in this document is subject to change without notice.
CE MARK R&RTTE Directive
Česky [Czech]: Polycom (UK) Ltd tímto prohlašuje, že tento RMX 4000 je ve shodě se
základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
Dansk [Danish]: Undertegnede Polycom (UK) Ltd erklærer herved, at følgende udstyr RMX
4000 overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/ EF.
Deutsch [German]: Hiermit erklärt Polycom (UK) Ltd, dass sich das Gerät RMX 4000 in
Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet.
Eesti [Estonian]: Käesolevaga kinnitab Polycom (UK) Ltd seadme RMX 4000 vastavust
direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
English: Hereby, Polycom (UK) Ltd. Declares that this RMX 4000 is in compliance with
the essential requirements and other relevant provisions of Directive 1999/5/EC.
Español [Spanish]: Por medio de la presente Polycom (UK) Ltd declara que el RMX 4000 cumple
con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
Ελληνική [Greek]: ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Polycom (UK) Ltd ΔΗΛΩΝΕΙ ΟΤΙ RMX 4000
ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.
Français [French]: Par la présente Polycom (UK) Ltd déclare que l’appareil RMX 4000 est
conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
Italiano [Italian]: Con la presente Polycom (UK) Ltd dichiara che questo RMX 4000 è conforme
ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Íslenska (Icelandic): Hér með lýsir Polycom (UK) Ltd yfir því að RMX 4000 er í samræmi við
grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC
Latviski [Latvian]: Ar šo Polycom (UK) Ltd deklarē
, ka RMX 4000 atbilst Direktīvas 1999/5/EK
būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.
Lietuvių [Lithuanian]: Šiuo Polycom (UK) Ltd deklaruoja, kad šis RMX 4000 atitinka esminius
reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.
Nederlands [Dutch]: Hierbij verklaart Polycom (UK) Ltd dat het toestel RMX 4000 in
overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
Malti [Maltese]: Hawnhekk, Polycom (UK) Ltd, jiddikjara li dan RMX 4000 jikkonforma mal-
ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
Magyar [Hungarian]: Alulírott, Polycom (UK) Ltd nyilatkozom, hogy a RMX 4000 megfelel a
vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Norsk [Norwegian]: Polycom (UK) Ltd erklærer herved at utstyret RMX 4000 er i samsvar med de
grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.
Polski [Polish]: Niniejszym Polycom (UK) Ltd oświadcza, że RMX 4000 jest zgodne z
zasadniczymi wymaganiami oraz innymi stosownymi postanowieniami Dyrektywy 1999/5/WE
Português [Portuguese]: Polycom (UK) Ltd declara que este RMX 4000 está conforme com os requisitos
essenciais e outras disposições da Directiva 1999/5/CE.
Slovensko [Slovenian]: Polycom (UK) Ltd izjavlja, da je ta RMX 4000 v skladu z bistvenimi zahtevami
in ostalimi relevantnimi določili direktive 1999/5/ES.
Slovensky [Slovak]: Polycom (UK) Ltd týmto vyhlasuje, že RMX 4000 spĺňa základné požiadavky
a všetky príslušné ustanovenia Smernice 1999/5/ES.
Suomi [Finnish]: Polycom (UK) Ltd vakuuttaa täten että RMX 4000 tyyppinen laite on direktiivin
1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Svenska [Swedish]: Härmed intygar Polycom (UK) Ltd att denna RMX 4000 står I
överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
Regulatory Notices
Russian Communication Certificate
The Polycom RMX™ 4000 complies with the Russian Ministry of Communication requirements stated in certificate 2795. Expiration date 17/03/2014.
Chinese Communication Certificate
Complies with IDA standards DA101619
Singapore Certificate

Table of Contents

Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Main Features .......................................................................................... 1-1
RMX 4000 Specifications ....................................................................... 1-2
RMX 4000 System Capacities ........................................................ 1-3
MPMx Resource Capacities .......................................................... 1-4
MPM+ Resource Capacities .......................................................... 1-5
MCU “Mode” Guidelines .............................................................. 1-6
MPMx and MPM+ Modes ..................................................... 1-6
Operating Mode Selection During Startup / Restart ........ 1-7
Safety Requirements .............................................................................. 1-8
Site Safety Requirements ............................................................... 1-8
General Installation Precautions .................................................. 1-9
Rack Mount Safety Precautions .................................................... 1-9
Installing the RMX 4000 ....................................................................... 1-10
Unpacking the RMX 4000 ............................................................ 1-10
Installing the RMX in a Rack or as a Standalone ..................... 1-12
Standalone RMX 4000 Installation ..................................... 1-12
Rack Mount Preparations .................................................... 1-12
Placing the RMX 4000 in a 19” Rack .................................. 1-13
Placing the RMX 4000 in a 23” Rack .................................. 1-15
Reverse Mounting the RMX 4000 in a Rack ..................... 1-16
Connecting the RMX 4000 to Power Sources ........................... 1-17
Connecting the RMX 4000 to AC Power ........................... 1-18
Connecting the RMX 4000 to -48DC SELV Power ........... 1-19
Types of DC Circuit Breakers installed on the RMX 4000 ......
Connecting Cables on the RMX 4000 ................................. 1-21
First-time Power-up ..................................................................... 1-22
RMX 4000 Components ....................................................................... 1-23
RMX 4000 Front Panel ................................................................. 1-23
RMX 4000 Rear Panel ................................................................... 1-27
RTM-IP 4000 .................................................................................. 1-28
RTM ISDN ..................................................................................... 1-30
Polycom RMX 4000 Hardware Guide
i
Table of Contents
ISDN/PSTN Clock Source .................................................. 1-31
RTM LAN ...................................................................................... 1-31
AC Power Entry Module (PEM) ................................................ 1-32
DC Power Rail Module ................................................................ 1-32
Component Slot Allocation ......................................................... 1-32
RMX 4000 LEDs .................................................................................... 1-34
RMX 4000 Front Panel LEDs ....................................................... 1-34
RMX 4000 Rear Panel LEDs ........................................................ 1-37
RTM-IP 4000 .......................................................................... 1-37
RTM LAN .............................................................................. 1-38
RTM ISDN ............................................................................. 1-39
Component Replacement . . . . . . . . . . . . . . . . . . . . . . . 2-1
Using the Modified PMC Compatible Ejector Lever ................ 2-3
Replacing the CNTL 4000 Module ............................................... 2-4
Replacing an AC Power Supply Module .................................... 2-5
Replacing an AC Power Entry Module (PEM) .......................... 2-6
Replacing a DC Power Rail Module (PRM) ............................... 2-7
Replacing the Fan Drawer ............................................................. 2-9
Inserting an Air Filter (Optional) in the Fan Drawer .............. 2-10
Replacing an Faulty MPM+/MPMx Card ................................ 2-11
Removing the MPM+/MPMx Card from the MCU ....... 2-11
Installing the Replacement MPM+/MPMx Card ............ 2-13
Installing an MPM+/MPMx Card on the RMX 4000 .............. 2-14
Replacing a RTM ISDN Card ...................................................... 2-14
Replacing the RTM-IP 4000 ......................................................... 2-16
Replacing the RTM LAN ............................................................. 2-17
Replacing the Fabric Switch Module (FSM 4000) .................... 2-18
ii

Hardware Description

This Hardware Guide provides information on the RMX 4000 and its components. This system utilizes a modular “universal slot” platform, whose components are designed for high performance, capacity and reliance.

Main Features

The Polycom RMX 4000 offers the following features:
•Linux® based
Chassis based on the ATCA standard
Built-in redundancy, hot swappable parts
Physical network and media separation between management and signaling networks, with high speed switching fabric on the media boards increasing system bandwidth
Support for standard network interfaces (IP, ISDN and LAN) and large number of ports.
H.323, SIP video, PSTN and ISDN
New hardware technologies
High availability, redundancy, on-line upgrading and dynamic resource allocation
Easy integration of conference elements into external network management
Enhanced Continuous Presence (multi-image video)
IVR (Interactive Voice Response) module
Resilient multipoint conferencing - Polycom Lost Packet Recovery (LPR)
1
Chapter 1- Hardware Description

RMX 4000 Specifications

Table 1-1 Polycom RMX 4000 Specifications
Physical
Height 6U (26.56 cm.) Width 19” (48.26 cm.) Depth 15.74” (40 cm.) Weight Up to 40 Kg.
Media Protocols
Audio G.711, G. 719, G.722, G.722.1, G .729A, G.723.1,
Video H.261, H.263, H.264.
Network Interfaces
IP, ISDN, PSTN and LAN H.323, SIP, PSTN, LAN and ISDN.
Siren14, Siren 22.
1-2
Power Supply
AC Input/ Range, BTU Voltage range:100-240 VAC, 14-7 AMP, 50/60
Hz. BTU output: 5120.
DC Input/Range, BTU Voltage range:-40.5-60 V DC SELV, with circuit
breaker. Typical: -48V DC Voltage up to 25 Amp. BTU output: 4270. Maximum 4600: per hour.
Power Consumption
AC Maximum Power consumption
DC Maximum Power consumption
Environment
1500Watts
1250Watts
Polycom RMX 4000 Hardware Guide
Table 1-1 Polycom RMX 4000 Specifications (Continued)
Operating temperature 10°– 40°C (50°– 104°F). Storage temperature -40°– 70°C (40°– 158°F). Relative humidity 15% - 90% no condensing. Operating altitude 60m below sea level, up to 3,000 m (10,000 ft.). Operating ESD 4kV.

RMX 4000 System Capacities

The following table summarizes the different system capacities.
Table 1-2 System Functions and Capacities RMX 4000
System Functions MPM+ Mode MPMx Mode
Maximum number of Video participants in a conference
Maximum number of PSTN participants in a conference
Maximum number of VOIP participants in a conference
Maximum number of Audio calls per second 55 Maximum number of Video calls per second 2 2 Maximum number of Conferences 800 800 Maximum number of Meeting Rooms 2000 2000 Maximum number of Entry Queues 80 80 Maximum number of Profiles 80 80 Maximum number of Conference Templates 200 200 Maximum number of SIP Factories 80 80 Maximum number of IP Services 11 Maximum number of ISDN Services 22
160 180
400 400
800 720
1-3
Chapter 1- Hardware Description
Table 1-2 System Functions and Capacities RMX 4000
System Functions MPM+ Mode MPMx Mode
Maximum number of IVR Services 80 80 Maximum number of Recording Links 20 (default) 20 (default) Maximum number of IVR Video Slides 150 150 Maximum number of Log Files (1Mb max.) 8000 8000 Maximum number of CDR Files 4000 4000 Maximum number of Fault Files 1000 1000 Number of Participant alerts Unlimited Unlimited Maximum number of concurrent RMX Web
Client connections to the MCU Maximum number Address Book entries 4000 4000 Maximum number of Users 100 100 Maximum number of Gateway Profiles 80 80 Maximum number of Reservations (internal
Scheduler)

MPMx Resource Capacities

Two MPMx card assemblies are available: MPMx - S (Single) and MPMx ­D (Double) each offer different resource capacities.
Table 1-1 summarizes the video capacities of the two MPMx card assemblies.
Table 2 MPMx – Resource Capacity per Card
Resource Type MPMx - S MPMx - D
Voice 180 360 H.263 CIF 30 60
20 20
4000 4000
1-4
H.263 4CIF15 15 30
Polycom RMX 4000 Hardware Guide
Tab le 2 MPMx – Resource Capacity per Card (Continued)
Resource Type MPMx - S MPMx - D
H.264 CIF/VSW 45 90 SD 30 60 HD720p30 15 30 HD720p60/
HD1080p30

MPM+ Resource Capacities

Three MPM+ card assemblies are available: MPM+ 80, MPM+ 40 and MPM+ 20 offering various resource capacities for CP conferences.
Table 1-1 summarizes the video capacities of the various MPM+ card assemblies.
Table 1-1 MPM+ Card Assemblies and Resource Capacities for CP
Conferences
Card Type
MPM+ 80 400 80 30 20 10 10 MPM+ 40 200 40 15 10 5 5 MPM+ 20 100 20 7 5 2 2
Table 1-2 summarizes the resource capacities of the various video resource types in an RMX containing MPM+ cards.
Voice CIF
815
(Symmetrical)
Resources
SD @30fps
HD720p @30fps
HD720p @60fps
HD1080p @30fps
Table 1-2 MPM+ Resource/Port Capacity
Resource Type Maximum Capacity (4 MPM+ Cards)
Voice 1600 PSTN 400
1-5
Chapter 1- Hardware Description
Table 1-2 MPM+ Resource/Port Capacity
Resource Type Maximum Capacity (4 MPM+ Cards)
CIF 320 SD30 120 HD720p 80 HD1080p 40 720p VSW 4Mb 160 1080p VSW 4Mb 160 1080p VSW 6Mb 80
RMX memory size is listed in the Administration > System Information properties box.
In HD Video Switching conferences, an RMX with four MPM+ cards can support up to 160 participants at HD1080p resolution at bandwidths of up to 4Mbps and 80 participants at HD1080p resolution at bandwidths of up to 6 Mbps.

MCU “Mode” Guidelines

MPMx and MPM+ Modes
MPMx and MPM+ cards installed in the system cannot be used simultaneously. Therefore, the RMX can operate in either an MPM+ or MPMx mode.
MPMx Mode is the mode in which the RMX operates to fully utilize the increased power and capacity of MPMx cards.
ISDN support is the same as for MPM+/MPMx cards.
G.719 audio algorithm is not supported with MPMx.
Operating Mode Selection During Startup / Restart
When started with Version 7.0 installed, the RMX enters MPMx Mode by default when no media cards are installed.
1-6
Polycom RMX 4000 Hardware Guide
The RMX switches between MPMx and MPM+ Card Configuration Modes
when MPM+/MPMx cards are removed or swapped while the system is running.
The switch between Card Configuration Modes occurs during the next
restart.
Installing or swapping MPM+/MPMx cards while the system is off will not
cause a switch in the Card Configuration Mode when the system is restarted – it will restart in the Card Configuration Mode that was active previous to powering down.
1-7
Chapter 1- Hardware Description

Safety Requirements

This section describes the requirements your site must meet for safe installation and operation of the system.

Site Safety Requirements

For your protection, please read these safety instructions completely before operating the equipment.
Look carefully for potential hazards in your work area: moist floors, ungrounded power cables, frayed power cords, missing safety grounds and so forth.
Locate the main circuit breaker within the room.
Locate the emergency power OFF switch within the room.
Never assume that power is disconnected from a circuit.
Use only the power cords supplied with the system.
Each power cord should only be connected to a power outlet that has a protective ground contact.
Ensure that power cords are easily accessible from the back of the system at all times.
Place the equipment in a well-ventilated area where the vents are free from obstruction.
Do not place heavy objects directly on top of the RMX 4000 unit.
Do not use liquids around your equipment.
Keep the area around the RMX 4000 clean and free of clutter.
Decide on a suitable location for the equipment rack that will hold the RMX
4000 unit. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet.
1-8
Polycom RMX 4000 Hardware Guide

General Installation Precautions

Attention:
The RMX 4000 can weigh up to 40kg when all slots are occupied. Two people are required to lift the MCU out of the box and also when installing it in a rack.
Use a regulating uninterruptable power supply (UPS) to protect the
RMX
4000 from power surges and voltage spikes, to keep your MCU operating in case of a power failure. The RMX 4000 requires either two (DC) or three (AC) power supply cables, each connected to a power supply.
Allow the power supply units to cool before touching them.
When handling electronic components, standard anti-static precautions must be observed:
Wear a grounding strapHandle cards by their edges only and do not touch their
components or connector pins
Keep components in anti-static bags, when not installed in the
RMX 4000

Rack Mount Safety Precautions

The following precautions should be followed when installing the RMX 4000 on a rack:
The RMX 4000 has a height of 6U. Ensure this space is available on the rack.
Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
In a single rack installation, stabilizers should be attached to the rack.
In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the rack.
You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable.
Before you install the rails, determine the placement of each component in the rack.
Install the heaviest components on the bottom of the rack first, and then work up.
1-9
Chapter 1- Hardware Description
Always keep the rack’s trays and card’s slots closed when not servicing, to maintain proper cooling.

Installing the RMX 4000

The following procedures have to be performed to install the RMX 4000 in your site:
Unpacking the RMX 4000
Installing the RMX in a rack or as a standalone
Connecting the RMX 4000 to the power source
Connecting the network (LAN, IP and ISDN) cables to the RMX

Unpacking the RMX 4000

To unpack and lift the RMX 4000:
1 When you receive the RMX 4000 packing case, inspect the equipment
for damage and verify that the components match the packing slip.
2 The RMX 4000 is shipped in a packing case with Stratocell®
packaging, and the top cover must be unlocked and lifted where the RMX is placed on the inside of an anti-static plastic bag.
3 Open the top cover of the packing case.
Two boxes are placed on the top Stratocell®, labelled: Installation Accessories. This kit contains the power cables and a
USB Key.
Rack Installation Accessories. This kit contains the accessories for
the 19” & 23” racks as follows:
1-10
Table 1-3 19” & 23” Rack Installation Accessories Package
Item ID Description Quantity
MEC2474A-L0 Chassis runner for rack installation
on the RMX 4000. 19” & 23” racks both require that these runners be installed on the rack.
MEC2475A-L0 23" bracket to be fitted to the front of
the RMX 4000.
2
2
Polycom RMX 4000 Hardware Guide
Make sure that boxes contain all the required parts.
4 Remove the boxes and top Stratocell®.
5 Holding the handle on each side, lift the RMX 4000 from the box, and
place it on a flat surface or install it in a rack. Remove any packaging material prior to positioning the RMX 4000.
Attention:
Two people are required to lift the MCU out of the box and when installing it in a rack.
1-11
Chapter 1- Hardware Description

Installing the RMX in a Rack or as a Standalone

Either place the RMX 4000 on a hard, flat surface such as a desktop or mount it on a 19”/23” rack.
Standalone RMX 4000 Installation
Place the RMX 4000 on a flat surface or desktop.
The RMX 4000 must rest on the four feet at the base of the MCU and must be shifted or moved into position using the two handles attached to the front.
Rack Mount Preparations
Optional - Depending on the rack installed in your site, you may need to remove the handles if they are attached to the RMX 4000. Unscrew the handles from the chassis as shown in “Optional - Fast feet and handle removal”.
Optional - If the opening in the rack that is allocated to the RMX 4000 is exactly 6U, the feet must be removed from the RMX 4000 to install it in the rack. Unscrew the feet from the chassis as shown in Figure 1-1, “Optional - Fast feet and handle removal”.
Figure 1-1,
1-12
Figure 1-1 Optional - Fast feet and handle removal
Polycom RMX 4000 Hardware Guide
Placing the RMX 4000 in a 19” Rack
1 When the RMX is to be rack mounted chassis runners must be
installed on the rack as shown in Figure 1-2. Two chassis runners are included in the Rack Installation Accessories kit and are attached facing inward from the outside of the 19”/23“rack mount.
Figure 1-2 Installing chassis runners and RMX in a rack
2 Mount the RMX on top of the rack brackets using the blades or
placing it on a rack mount shelf with runners.
1-13
Chapter 1- Hardware Description
3 Fasten the RMX to the rack with 8 screws into the holes provided on
Figure 1-3 RMX 4000 Rack Mount
the RMX’s front as shown in Figure 1-3.
1-14
Rack mounting screws must be supplied by the rack’s manufacturer.
The airflow of the RMX 4000 is from right to left. Be sure that the areas on the left and right side of the system are clear for proper
ventilation.
When the unit is installed on a rack, the rack must be properly grounded to the central office ground. The rack must be grounded with two-hole compression­type connectors using copper conductors (tinned or untinned). Wire, bus bar or braided strap connectors are acceptable.
Loading...