Polycom DOC2557B User Manual

Polycom® RMX
®
Hardware Guide
1500
Version
7.0.1
Trademark Information
Polycom®, the Polycom “Triangles” logo, and the names and marks associated with Polycom’s products are trademarks and/or service marks of Polycom, Inc., and are registered and/or common-law marks in the United States and various other countries.
All other trademarks are the property of their respective owners.
Patent Information
The accompanying product is protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc.
© 2010 Polycom, Inc. All rights reserved.
Polycom, Inc. 4750 Willow Road Pleasanton, CA 94588-2708 USA
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Polycom, Inc. Under the law, reproducing includes translating into another language or format. As between the parties, Polycom, Inc., retains title to and ownership of all proprietary rights with respect to the software contained within its products. The software is protected by United States copyright laws and international treaty provision. Therefore, you must treat the software like any other copyrighted material (e.g., a book or sound recording).
Every effort has been made to ensure that the information in this manual is accurate. Polycom, Inc., is not responsible for printing or clerical errors. Information in this document is subject to change without notice.
Table of Contents
Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Main Features .......................................................................................... 1-1
RMX 1500 Specifications ....................................................................... 1-2
RMX 1500 System Capacities ................................................................ 1-3
Site Requirements ................................................................................... 1-5
Safety Requirements ...................................................................... 1-5
Rack Mount Safety Precautions .................................................... 1-5
Installation Precautions ................................................................. 1-6
Connecting the RMX 1500 to a Power Source ............................ 1-7
Connecting the RMX 1500 to AC Power ............................. 1-7
Connecting Cables on the RMX 1500 ........................................... 1-8
First-time Power-up ....................................................................... 1-8
RMX 1500 Components ....................................................................... 1-10
RMX 1500 Front Panel ................................................................. 1-10
Opening the RMX 1500 Front Panel .................................. 1-10
Front Panel Components ..................................................... 1-11
RMX 1500 Rear Panel ................................................................... 1-12
RTM IP 1500 .......................................................................... 1-12
RTM ISDN 1500 .................................................................... 1-14
ISDN/PSTN Clock Source .................................................. 1-15
RMX 1500 Power Supply ............................................................. 1-15
Power Supply LEDs ............................................................. 1-15
RMX 1500 LEDs .................................................................................... 1-16
RMX 1500 Front Panel LEDs ....................................................... 1-16
RMX 1500 Rear Panel LEDs ........................................................ 1-17
RTM IP 1500 LEDs ................................................................ 1-17
RTM ISDN 1500 LEDS ......................................................... 1-19
Power Supply LEDs ............................................................. 1-19
Component Installation & Replacement . . . . . . . . . . . . 2-1
Installing the RTM ISDN 1500 Card ............................................ 2-2
Component Replacement ...................................................................... 2-4
Replacing the RTM ISDN 1500 ..................................................... 2-5
Polycom RMX 1500 Hardware Guide
i
Table of Contents
ii
Hardware Description
This Hardware Guide provides information on the RMX 1500 and its components. This system utilizes a modular platform, whose components are designed for high performance, capacity and reliance.
Main Features
The Polycom RMX 1500 offers the following features:
•Linux® based
Chassis based on the ATCA standard
Support for standard network interfaces (H.323, SIP video, ISDN, PSTN and LAN)
New hardware technologies
Telco grade high availability, on-line upgrading and dynamic resource allocation
Easy integration of conference elements into external network management
Enhanced Continuous Presence (multi-image video)
IVR (Interactive Voice Response) module
1
1-1
Chapter 1-Hardware Description
RMX 1500 Specifications
Table 1-1 Polycom RMX 1500 Specifications
Physical
Height 1U (4.44 cm.) Width 19” (48.26 cm.) Depth 23.6” (60 cm.) Weight Up to 12 Kg.
Media Protocols
Audio G.711, G. 719, G.722, G.722.1, G.729A, G.723.1,
Video H.261, H.263, H.264.
Network Interfaces
IP, ISDN, PSTN and LAN H.323, SIP, ISDN, PSTN and LAN
Siren14, Siren 22.
1-2
Power Supply
AC Input/ Range, BTU Voltage range: 100-240 VAC ±10%, 47-63 Hz.
Maximum BTU output: 3400 per hour.
Power Consumption
AC Maximum Power consumption
Environment
Operating temperature 0°– 40°C (22°– 104°F). Storage temperature -40°– 70°C (-40°– 158°F). Relative humidity 15% - 90% no condensing. Operating altitude Up to 4,500 m (15,000 ft.). Operating ESD 4 kV.
350 Watts.
RMX 1500 System Capacities
Conferencing Capacities
The following table summarizes the different system capacities.
Table 1-2 System Functions and Capacities RMX 1500
System Functions Capacity
Maximum number of Video participants in a conference 90 Maximum number of PSTN participants in a conference 120 Maximum number of VOIP participants in a conference 360 Maximum number of Audio calls per second 5 Maximum number of Video calls per second 2 Maximum number of Conferences 400 Maximum number of Meeting Rooms 1000
Polycom RMX 1500 Hardware Guide
Maximum number of Entry Queues 40 Maximum number of Profiles 40 Maximum number of Conference Templates 100 Maximum number of SIP Factories 40 Maximum number of IP Services 1 Maximum number of ISDN Services 2 Maximum number of IVR Services 40 Maximum number of Recording Links 20 (default) Maximum number of IVR Video Slides 150 Maximum number of Log Files (1Mb max.) 4000 Maximum number of CDR Files 2000 Maximum number of Fault Files 1000 Number of Participant alerts Unlimited
1-3
Chapter 1-Hardware Description
Table 1-2 System Functions and Capacities RMX 1500
System Functions Capacity
Maximum number of concurrent RMX Web Client connections to the MCU
Maximum number of Users 100 Maximum number Address Book entries 4000 Maximum number of gateway profiles 40 Maximum number of Reservations (Internal Scheduler) 2000
20
Resource Capacities
Table 1-3 System Resource Capacities According to Video Resolution
Resource Type/Video Resolution Resources with MPMx
HD Support CP / VSW CIF H.263 60 CIF H.264 90 SD / 4CIF H.264 60 4CIF H.263 30 720p30 30
1-4
1080p30fps/720p60 15 (Symmetric) VSW 2Mb 80 VSW 4Mb 40 VSW 6Mb 20 VOIP 360 PSTN 120 ISDN 60 (at 128 Kbps) - 4 E1/T1
Site Requirements
This section describes the requirements your site must meet for safe installation and operation of the system.
Safety Requirements
For your protection, please read these safety instructions completely before operating the equipment.
Look carefully for potential hazards in your work area: moist floors, ungrounded power cables, frayed power cords, missing safety grounds and so forth.
Locate the main circuit breaker within the room.
Locate the emergency power OFF switch within the room.
Never assume that power is disconnected from a circuit.
Use only the power cord supplied with the system.
The power cord should only be connected to a power outlet that has a protective ground contact.
Ensure that the power cord is easily accessible from the back of the system at all times.
Place the equipment in a well-ventilated area where the vents are free from obstruction.
Do not place heavy objects directly on top of the RMX 1500 unit.
Do not use liquids around your equipment.
Polycom RMX 1500 Hardware Guide
Rack Mount Safety Precautions
The following precautions should be followed with regards to rack mount safety:
Keep the area around the RMX 1500 clean and free of clutter.
Decide on a suitable location for the equipment rack that will hold the RMX 1500 unit. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet.
Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.