remove from
skid
connect the
power
connect
solution and
vaccuum
hoses
connect the
wand
fill the
solution tank
turn pump
switches and
vacuum
switches on
on at a time.
now you are
ready to
clean
Connecting the power
Connect the female sockets of the supplied extension cords to the panel sockets. Note: You must connect both cord to operate the machine and when using at pressure above 400 psi, you must connect to two separate power phases in the building.
Pressure Hose Vacuum Hose
Connect the supplied hoses to the above pictured connection. To connect the pressure hose push the sleeve back on the brass socket insert the male plug then release. To connect the vacuum hose just insert the black hose cuff into plastic pipe.
Pressure Hose Vacuum hose
Connect the female pressure hose fitting to the male wand connector and slide the cuff over the end of the wand. You may need to replace trigger kits See below.
Filling the tank use a bucket or hose to fill the solution tank, you can use water with a temp up to max of 70 degree Celcius. If you have the option extra of auto fill, just connect hose to the Connector on the body.
1. To engage the heater on press the toggle to the heater position.
Please the heater is designed to kept the water heated while not being used, its intension is not to turn cold water to hot. (switch 1)
2. Before we can start spraying, you need to return the switch the
pump position. (switch 1)
3. Once ready to start turn the round switch on one at a time to
prevent overload on the power.( switch 2,3,4).
4. Opiontal auto pump out, if fitted use switch 5 to turn on.
Pressure gauge / Pressure control
Warning!!! It is important to control the predator pressure output.
Hose Connector
Auto fill Option
5