1. Introduction
This array online UPS supplies power immediately to prevent the data lost and your system damaged
when the main power is abnormal. With WinPower software, the uninterruptible power supply (UPS) will
safely store data and shut down your network operating system before the battery is fully discharged,
whether you’re there or not. It provides perfect protection specifically for fileservers, minicomputers, internet
hubs, telecommunication systems and other mission-critical applications.
This array online UPS includes: 1KRS(L), 2KRL, 3KRL, 6KRL. The models with L extension allow for
expanding runtime by simply plugging in additional battery packs.
2. Safety instructions
Please read the following user manual and the safety instructions before installing the unit and starting it
up!
Transport
Please transport the UPS system only in the original packaging (to protect against shock and impact).
Set-up
Ø Condensation may occur if the UPS system is moved directly from a cold to a warm environment. The
UPS system must be absolutely dry before being installed. Please allow an acclimatization time of at
least two hours.
Ø Do not install the UPS system near water or in damp environment.
Ø Do not install the UPS system where it would be exposed to direct sunlight or near heat.
Ø Do not block off ventilation openings in the UPS system’s housing.
Installation
Ø Do not connect appliances or equipment which would overload the UPS system (e.g. laser printers) to
the UPS output socket.
Ø Place cables in such a way that no one can step on or trip over them.
Ø Do not connect domestic appliances such as hair dryers to UPS output sockets.
Ø The UPS can be operated by any individuals with no previous technical experience.
The following for 1KRS(L)/2KRL/3KRL specially:
Ø Assure to connect with the earth reliably.
Ø The building wiring socket outlet (shockproof socket outlet) must be easily accessible and close to the
UPS system.
Ø With the installation of the equipment, the sum of the leakage current of the UPS and the connected
consumer does not exceed 3.5mA.
The following for 6K specially:
Ø Warning -- this is a product for restricted sales distribution to informed partners. Installation
restrictions or additional measures may be needed to prevent disturbances.
Ø A readily accessible disconnect device shall be incorporated in the building installation wiring and the
disconnect device must be easily accessible and close to the UPS system.
Ø This is permanently connected equipment and only qualified maintenance personnel may carry out
installations.
Operation
Ø The UPS system features its own, internal current source (batteries). The UPS output sockets may be
still exists even if the UPS system is not connected to the building wiring socket outlet.
Ø In order to fully disconnect the UPS system, firstly press the standby switch then disconnect the mains
lead.
Ø Ensure that no fluids or other foreign objects can enter the UPS system.