Pocasa 1KRS, 2KRL, 1KRSL, 3KRL, 6KRL User Manual

1
H series array online UPS 1-6KRS/L
U
U
U
s
s
s
e
e
e
s
s
s
m
m
m
a
a
a
n
n
n
u
u
u
a
a
a
l
l
l
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
2
Contents
1. Introduction----------------------------------------------------------------------------------------------------------------------1
2. Safety instructions-------------------------------------------------------------------------------------------------------------2
3. System description-------------------------------------------------------------------------------------------------------------4
3.1. Front panel-----------------------------------------------------------------------------------------------------------------4
3.2. Rear panel------------------------------------------------------------------------------------------------------------------5
4. Maintenance---------------------------------------------------------------------------------------------------------------------7
4.1. Operation environment--------------------------------------------------------------------------------------------------7
4.2. Battery application--------------------------------------------------------------------------------------------------------7
4.3. Trouble shooting-----------------------------------------------------------------------------------------------------------7
5. Technical data-------------------------------------------------------------------------------------------------------------------8
5.1. Electrical specifications-------------------------------------------------------------------------------------------------8
5.2. Typical stored energy time----------------------------------------------------------------------------------------------8
5.3. Mechanical data-----------------------------------------------------------------------------------------------------------8
5.4. CE conformity--------------------------------------------------------------------------------------------------------------9
5.5. Communication port------------------------------------------------------------------------------------------------------9
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
3
1. Introduction
This array online UPS supplies power immediately to prevent the data lost and your system damaged when the main power is abnormal. With WinPower software, the uninterruptible power supply (UPS) will safely store data and shut down your network operating system before the battery is fully discharged, whether youre there or not. It provides perfect protection specifically for fileservers, minicomputers, internet hubs, telecommunication systems and other mission-critical applications.
This array online UPS includes: 1KRS(L), 2KRL, 3KRL, 6KRL. The models with L extension allow for expanding runtime by simply plugging in additional battery packs.
2. Safety instructions
Please read the following user manual and the safety instructions before installing the unit and starting it up!
Transport
Please transport the UPS system only in the original packaging (to protect against shock and impact). Set-up
Ø Condensation may occur if the UPS system is moved directly from a cold to a warm environment. The
UPS system must be absolutely dry before being installed. Please allow an acclimatization time of at least two hours.
Ø Do not install the UPS system near water or in damp environment.
Ø Do not install the UPS system where it would be exposed to direct sunlight or near heat.
Ø Do not block off ventilation openings in the UPS systems housing.
Installation
Ø Do not connect appliances or equipment which would overload the UPS system (e.g. laser printers) to
the UPS output socket.
Ø Place cables in such a way that no one can step on or trip over them.
Ø Do not connect domestic appliances such as hair dryers to UPS output sockets.
Ø The UPS can be operated by any individuals with no previous technical experience.
The following for 1KRS(L)/2KRL/3KRL specially:
Ø Assure to connect with the earth reliably.
Ø The building wiring socket outlet (shockproof socket outlet) must be easily accessible and close to the
UPS system.
Ø With the installation of the equipment, the sum of the leakage current of the UPS and the connected
consumer does not exceed 3.5mA.
The following for 6K specially:
Ø Warning -- this is a product for restricted sales distribution to informed partners. Installation
restrictions or additional measures may be needed to prevent disturbances.
Ø A readily accessible disconnect device shall be incorporated in the building installation wiring and the
disconnect device must be easily accessible and close to the UPS system.
Ø This is permanently connected equipment and only qualified maintenance personnel may carry out
installations.
Operation
Ø The UPS system features its own, internal current source (batteries). The UPS output sockets may be
still exists even if the UPS system is not connected to the building wiring socket outlet.
Ø In order to fully disconnect the UPS system, firstly press the standby switch then disconnect the mains
lead.
Ø Ensure that no fluids or other foreign objects can enter the UPS system. Maintenance, servicing and faults
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
4
Ø The UPS system operates with hazardous voltage. Repair may be carried out only by qualified
maintenance personnel.
Caution -- risk of electric shock. Even some the unit is disconnected with the mains power supply (building wiring socket outlet), components inside the UPS system are still connected to the battery and are still electrically live and dangerous.
Ø Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and verify
that no current is present and no hazardous voltage exist in the terminals of high capability capacitor such as BUS-capacitors.
Ø Only persons adequately familiar with batteries and with the required precautionary measures may
exchange batteries and supervise operations. Unauthorized persons must be kept away from the batteries.
Caution -- risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous voltages may occur between the battery terminals and the ground. Before touching any operation, please verify that no voltage is present!
Ø Batteries may cause electric shock and have a high short-circuit current. Please take the
precautionary measures specified below when working with batteries:
-- remove wristwatches, rings and other metal objects
-- use only tools with insulated grips and handles.
Ø When exchange batteries, install the same number and type of batteries.
Ø Do not attempt to dispose of batteries by burning them. This could cause battery explosion.
Ø Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be
toxic.
Ø Please replace the fuse only with a fuse of the same type and amperage in order to avoid fire hazards.
3. System description
3.1. Display panel
The UPS power control and operating indicators are located on the front display panel.
ON-SWITCH
Ø The UPS can be turned on by pressing ON-SWITCH button for at least 1 second.
Ø The acoustic alarm can be deactivated by pressing ON-SWITCH button.